• Title/Summary/Keyword: Position Variation

Search Result 1,192, Processing Time 0.033 seconds

Effects of Change in the Height of Therapy Tables on the Fatigue of Splenius Capitis Muscle and Trapezius Muscle

  • Kim, Young Hoon;Noh, Ji Bin;Joo, Sung Hoon;Choi, Jung Hyun;Yoon, Jung Gyu;Lee, Sang Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.1
    • /
    • pp.516-522
    • /
    • 2013
  • The purpose of this study is to analysis of muscle fatigue in the upper trapezius and splenius capitis muscles according to therapy table height variation. The subjects were consisted of 15 healthy adults(10 males, 5 females) who had no medical history of neurological and musculoskeletal problems. In experiment, wireless electrode EMG system was measured for each the upper trapezius and splenius capitis muscles during the treatment performed on table. the differences in the muscle fatigue was compared for 4 types of table height(-6cm, -3cm, 0, +3cm from elbow in $90^{\circ}$ flexion position). Muscle fatigue according to therapy table height were significant difference except for left upper trapezius. And muscle fatigue of right upper trapezius and splenius capitis showed significant decrease in +3cm table height compared to -6cm table height(p<.05). Muscle fatigue of right upper trapezius and splenius capitis were the highest in -6cm table height, but those were the lowest in +3cm table height. This study propose to change therapy table height higher than +3cm from elbow in $90^{\circ}$ flexion position, if you hope to reduce muscle fatigue.

Study on the Internal Flow of an Electric Oven with Variation of Steam Outlet Position (전기오븐의 스팀 출구위치에 따른 내부유동에 대한 연구)

  • Park, Young Hun;Kim, Yu Jin;Jung, Young Man;Park, Warn-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.450-456
    • /
    • 2013
  • The composite electric oven is one of the fixing utensil, various functions are required. Steam generating function, which is one of its functions, and allows various food cooking. The location of the outlet of the steam generator is designed around ease of installation, consideration of internal fluid is not. Distribution of the steam can not be non-uniformly. Accordingly, cooking time becomes longer, the energy consumption increases. As a result of the analysis, it was confirmed stagnation phenomenon of the internal flow through the interpretation of the calculations for the position of the outlet of the steam generator existing. Further, by computing the analysis of various locations of the outlet of the steam generator, we investigated the distribution and characteristics of the internal flow.

Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design

  • Myung, Yujin;Lee, Jong-Gu;Cho, Maenghyo;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.386-389
    • /
    • 2019
  • The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.

THE INFLUENCE OF STABILIZATION SPLINT ON CONDYLAR POSITION AND CRANIOFACIAL MORPHOLOGY

  • Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.675-688
    • /
    • 1995
  • The purposes of this study were:1) to determine the normal range of CR-CO discrepancy in normal occlusion group ; 2) to evaluate the changes of condylar position and craniofacial morphology between centric relation and centric occlusion before and after stabilization splint therapy in malocclusion group outside the normal range of CR-CO discrepancy. The normal occlusion group consisted of 80 subjects who had well-balanced faces and good occlusions with acceptable Class I molar relationship. They had not been treated orthodontically and had no signs or symptoms of temporomandibular joint dysfunction. 71 malocclusion patients enrolled for orthodontic treatment at the Department of Orthodontics, College of Dentistry, Chosun University comprised the malocclusion group, little variation of growth factor by the second molar eruption. They had CR-CO discrepancy beyond normal range and were subdivided into anterior-posteriorly -[25 Class I (0$\geq$4), and 24 Class III (ANB$\leq$0)] : vertically - [20 Normodivergentscy (30$\geq$34), and 18 Hypodivergency (SNGoMe$\leq$30)] ; and sexually - [26 Male and 45 Female]. For malocclusion group, stabilization splint with mutually protected type of occlusal scheme was applied for three months. Panadent articulators, Panadent condylar position indicator (CPI), and lateral headfilm were used to investigate the influence of stabilization splint on condylar position and craniofacial morphology. The results of this study were as follows. 1. The amounts of CR-CO discrepancy in normal occlusion were that the antero-Posterior component (${\bigtriangledown}X$) was $0.56\pm0.46mm$ (Male:$0.63\pm0.42mm$, Female:$0.49\pm0.50mm$) ; the supero-inferior component (${\bigtriangledown}Y$) was $-0.75\pm0.48mm$ (Male:$-0.76\pm0.52mm$, Female:-$0.73\pm0.43mm$) : and the transverse component (${\bigtriangledown}Z$) was $-0.33\pm0.28mm$ (Male : $-0.38\pm0.29mm$, Female:$-0.31\pm0.27mm$). 2. The condylar position was in normal range after stabilization splint therapy. 3. The mandible was always rotated infero-posteriorly after stabilization splint therapy. 4. Antero-posteriorly, Class III malocclusion responded very well to the stabilization splint therapy. 5. Vertically, Hyperdivergency responded very well to the stabilization splint therapy 6. Sexually, Male responded very well to the stabilization splint therapy.

  • PDF

The Effects of Multi Joint-Joint Position Sense Training Using Functional Task on Joint Position Sense, Balance, Walking Ability in Patients With Post-Stroke Hemiplegia (기능적 과제를 통한 다관절 관절위치감각 훈련이 뇌졸중 환자의 관절위치감각, 균형, 보행능력에 미치는 효과)

  • Ko, Kyoung-hee;Choi, Jong-duk;Kim, Mi-sun
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.33-40
    • /
    • 2015
  • The purpose of this study was to investigate the effect of multi joint-joint position sense (MJ-JPS) training on joint position sense, balance, and gait ability in stroke patients. A total of 18 stroke patients participated in the study. The subjects were allocated randomly into two groups: an experimental group and a control group. Participants in the experimental group received MJ-JPS training (10 min) and conventional treatment (20 min), but participants in the control group only received conventional treatment (30 min). Both groups received training for five times per week for six weeks. MJ-JPS is a training method used to increase proprioception in the lower extremities; as such, it is used, to position the lower extremities in a given space. MJ-JPS measurement was captured via video using a Image J program to calculate the error distance. Balance ability was measured using Timed Up and Go (TUG) and the Berg Balance Scale (BBS). Gait ability was measured with a 10 m walking test (10MWT) and by climbing four flights of stairs. The Shapiro-Wilk test was used to assess normalization. Within-group differences were analyzed using the paired t-test. Between-group differences were analyzed using the independent t-test. The experimental group showed a significant decrease in error distance (MJ-JPS) compared to the control group (p<.05). Both groups showed a significant difference in their BBS and 10MWT results (p<.05). The experimental group showed a significant decrease in their TUG and climbing results (p<.05), but the control group results for those two tasks were not found to be significant (p>.05). There was significant difference in MJ-JPS and by climbing four flights of stairs on variation of pre and post test in between groups (p<.05), but TUG and BBS and 10MWT was no significantly (p>.05). We suggest that the MJ-JPS training proposed in this study be used as an intervention to help improve the functional activity of the lower extremities in stroke patients.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

Prediction on the Performance Variation by the Rover Position of the One-way Network RTK (사용자 위치별 단방향 Network RTK 측위 성능 예측)

  • Park, Byungwoon;Wang, Namkyong;Kee, Changdon;Park, Heungwon;Seo, Seungwoo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.107-108
    • /
    • 2014
  • As the demand for precise navigation has increased, more focus is put on the precise positioning, RTK(Real Time Kinematics) which has been used in the surveying field. The Position of Single Reference Station RTK or two-way network RTK such as VRS (Virtual Reference Station) is accurate enough to be used as a main technology in land surveying, however its service area and number of users is limited and the users are assumed static. This characteristic is not suitable to the navigation, whose service target is infinite number of users moving over a wide area. One-way network RTK has recently been suggested as a solution for the precise navigation technique for the mobile user. This paper shows the performance prediction of the one-way network RTK such as MAC(Master-Auxiliary Concept), or FKP (Flachenkorrekturparameter). To show the performance variation by the rover position, we constructed a simulation data of users on the grid with 0.1 degree spacing between 36.5 and 37 degree latitude and between 127 and 127.5 degree longitude.

  • PDF

Investigation on Combustion Characteristics According to Spark Plug Protrusion in SI Engine (점화플러그 삽입 위치에 따른 SI 엔진의 연소특성에 관한 연구)

  • Han Young-Chool;Kim Dae-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1163-1171
    • /
    • 2004
  • The variation of spark plug location have one of the effects on combustion characteristics. Several parameters of the effect on combustion characteristics are shape of combustion chamber, the spark plug position, turbulence flow and so on. This paper presents an experimental study according to variation of spark plug protrusion and PDA valve which have effects on characteristics of combustion and emission in single cylinder gasoline engine. Also, this paper emphasized that combustion stabilization was making by way of the reinforcement of the turbulent flow with the PDA valve. A feasibility and necessity of combustion pressure based cylinder spark timing control according to spark plug protrusion has been examined. So, this was obtained COV$\_$imep/ and the mass fraction burned(MFB) and the specific fuel consumption(sfc). Using the results of the test, the effects of the variable spark plug location and PDA valve can be improved fuel consumption and be available for the combustion stability.

Sensorless Vector Control of a Wound Induction Motor Using MRAS with On-Line Stator Resistance Tuning

  • Lee Jae-Hak;Kim Yoon-Ho;Lee Houng-Gyun;Woo Hyuk-Jae
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.462-465
    • /
    • 2001
  • The wound induction motor can provide high starting torque and reduced starting current simultaneously by inserting large scale resistor. And this technique is one of the well known methods among the induction motor starting methods and generally used for heavy load starting such as Crain and Cement factories. The conventional PI controller has been widely used in industrial application due to the simple control algorithm and in general, PI controller is used for control of current, torque, position, and speed for the wound induction motor drive system. However, the system may result in poor performance since sensors have to be used, which in turn is limited by the environmental condition. Recently, to overcome these problems, many sensorless vector control methods for the wound induction motor have been studied. This paper presents MRAS method with on-line stator resistance tuning for sensorless vector control of the wound induction motor drive. In conventional MRAS method, in low frequency, stator resistance variation can result in poor performance. Therefore, to overcome several shortages of the conventional MRAS caused by parameter variation and enhance robustness of the sensor less vector control, this paper investigates a MRAS method with on-line stator resistance tuning for sensorless vector control of the wound induction motor. The validity and effectiveness of the proposed method is verified through digital simulation.

  • PDF

A Study on the Introduction of Derivatives for Hedge of Housing Rent Price -Targeting Apartment Rent Price in Gangnam and Gangbuk Regions of Seoul- (주택전세가격 헤지를 위한 파생상품 도입 연구 - 서울시 강남, 강북지역 아파트 전세가격을 대상으로 -)

  • Choi, In-Sik;Yoo, Seung-Kyu;Kim, Jae-Jun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • This study aimed to seek a method capable of hedging a rising risk of housing rent price by introducing derivatives with the target of Korean housing rent markets. The research model used in this thesis progressed a research by applying a futures contract method with the target of the rent price of major apartments in Gangnam and Gangbuk Regions of Seoul. As an analysis result, the rent price of all complexes has risen during its analysis period, so it could be confirmed that the CRB future index was also risen according to this. Finally, it was confirmed that the rising risk of the rent price can be hedged through a purchase position of futures. But, as the difference between rent price variation and CRB future index variation occurs, it appeared that 100% of hedge is difficult. However, it is judged that if considering that a method capable of hedging the rising risk of the existing rent price was nonexistent, the hedge trading effect utilizing the CRB future index on the rent price will be meaningful.