• Title/Summary/Keyword: Position Variation

Search Result 1,192, Processing Time 0.164 seconds

An analytical approach of behavior change for concrete dam by panel data model

  • Gu, Hao;Yang, Meng;Gu, Chongshi;Cao, Wenhan;Huang, Xiaofei;Su, Huaizhi
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.521-531
    • /
    • 2020
  • The behavior variation of concrete dam is investigated, based on a new method for analyzing the data model of concrete dam in service process for the limitation of wavelet transform for solving concrete dam service process model. The study takes into account the time and position of behavior change during the process of concrete dam service. There is no dependence on the effect quantity for overcoming the shortcomings of the traditional identification method. The panel data model is firstly proposed for analyzing the behavior change of composite concrete dam. The change-point theory is used to identify whether the behavior of concrete dams changes during service. The phase space reconstruction technique is used to reconstruct the phase plane of the trend effect component. The time dimension method is used to solve the construction of multi-transformation model of composite panel data. An existing 76.3-m-high dam is used to investigate some key issues on the behavior change. Emphasis is placed on conversion time and location for three time periods consistent with the practical analysis report for evaluating the validity of the analysis method of the behavior variation of concrete dams presented in this paper.

Structural Variation of Diamond-like Carbon Thin Film According to the Annealing Temperature (열처리온도에 따른 다이아몬드상 카본박막의 구조적 특성변화)

  • Choi Won-Seok;Park Mun-Gi;Hong Byung-You
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.8
    • /
    • pp.701-706
    • /
    • 2006
  • In addition to its similarity to genuine diamond film, diamond-like carbon (DLC) film has many advantages, including its wide band gap and variable refractive index. In this study, DLC films were prepared by the RF PECVD (Plasma Enhanced Chemical Vapor Deposition) method on silicon substrates using methane $(CH_4)$ and hydrogen $(H_2)$ gas. We examined the effects of the post annealing temperature on the structural variation of the DLC films. The films were annealed at temperatures ranging from 300 to $900^{\circ}C$ in steps of $200^{\circ}C$ using RTA equipment in nitrogen ambient. The thickness of the film and interface between film and substrate were observed by surface profiler, field emission scanning electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM), respectively. Raman and X-ray photoelectron spectroscopy (XPS) analysis showed that DLC films were graphitized ($I_D/I_G$, G-peak position and $sp^2/sp^3$ increased) ratio at higher annealing temperature. The variation of surface as a function of annealing treatment was verified by a AFM and contact angle method.

Dynamic / Static Object Segmentation and Visual Encryption Mechanism for Storage Space Management of Image Information (영상정보의 저장 공간 관리를 위한 동적/정적 객체 분리 및 시각암호화 메커니즘)

  • Kim, Jinsu;Park, Namje
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.10
    • /
    • pp.1199-1207
    • /
    • 2019
  • Video surveillance data, which is used for preemptive or post-emptive action against any event or accident, is required for monitoring the location, but is reducing the capacity of the image data by removing intervals for cost reduction and system persistence. Such a video surveillance system is fixed in a certain position and monitors the area only within a limited angle, or monitors only the fixed area without changing the angle. At this time, the video surveillance system that is monitored only within a limited angle shows that the variation object such as the floating population shows different status in the image, and the background of the image maintains a generally constant appearance. The static objects in the image do not need to be stored in all the images, unlike the dynamic objects that must be continuously shot, and occupy a storage space other than the necessary ones. In this paper, we propose a mechanism to analyze the image, store only the small size image for the fixed background, and store it as image data only for variable objects.

Fusarium Species from Sorghum in Thailand

  • Mohamed Nor, Nik M.I.;Salleh, Baharuddin;Leslie, John F.
    • The Plant Pathology Journal
    • /
    • v.35 no.4
    • /
    • pp.301-312
    • /
    • 2019
  • Sorghum is the fifth most important cereal worldwide, spreading from Africa throughout the world. It is particularly important in the semi-arid tropics due to its drought tolerance, and when cultivated in Southeast Asia commonly occurs as a second crop during the dry season. We recovered Fusarium from sorghum in Thailand and found F. proliferatum, F. thapsinum and F. verticillioides most frequently, and intermittent isolates of F. sacchari and F. beomiforme. The relatively high frequencies of F. proliferatum and F. verticillioides, suggest mycotoxin contamination, particularly fumonisins and moniliformin, should be evaluated. Genetic variation within the three commonly recovered species was characterized with vegetative compatibility, mating type, Amplified Fragment Length Polymorphisms (AFLPs), and female fertility. Effective population number ($N_e$) was highest for F. verticillioides and lowest for F. thapsinum with values based on mating type allele frequencies higher than those based on female fertility. Based on AFLP genetic variation, the F. thapsinum populations were the most closely related, the F. verticillioides populations were the most distantly related, and the F. proliferatum populations were in an intermediate position. The genetic variation observed could result if F. thapsinum is introduced primarily with seed, while F. proliferatum and F. verticillioides could arrive with seed or be carried over from previous crops, e.g., rice or maize, which sorghum is following. Confirmation of species transmission patterns is needed to understand the agricultural systems in which sorghum is grown in Southeast Asia, which are quite different from the systems found in Africa, Australia, India and the Americas.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Effect of the slice thickness and the size of region of interest on CT number (상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향)

  • Lee Ji-Youn;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

Fabrication of electrodes on mcirochannel side wall using shadow evaporation effect (샤도우 증착 효과를 이용한 마이크로 채널내 측벽 전극 제작)

  • 강길환;김규만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1462-1465
    • /
    • 2004
  • A new method to fabricate metal electrodes on side wall of the microchannel is presented. Coulter counter allows to count the number of cell passing through the microchannel by detecting impedance variation between two electrodes. The relative position of two electrodes is important for sensitivity of impedance measurement. 100nm thick Al electrodes are deposited on the channel side wall by means of shadow evaporation.

  • PDF

Development of driver for BLDC motor system and precise repetitive control (BLDC 모터의 구동장치 개발 및 정밀 반복제어)

  • 강병철;이충환;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1257-1260
    • /
    • 1996
  • This paper describes a fully digitalized driver for BLDC motors and the driver is realized by a single chip microprocessor. The speed change can be done by using the signal obtained from the position detecting sensor and adjusting the pulse width at the input channel of power module. In order to verify the effectiveness, an repetitive control method is adopted in the speed control tracking a periodic reference change in the BLDC motor system. The experimental results are shown for the reference tracking accurately according to the design parameter variation in the repetitive controller design.

  • PDF

조선왕조실록(朝鮮王朝實錄)에 기재된 Kepler초신성(超新星)의 관측기록

  • Yu, Gyeong-No
    • Publications of The Korean Astronomical Society
    • /
    • v.5 no.1
    • /
    • pp.85-94
    • /
    • 1990
  • Wangjo Silok, the official chronicle of Lee Dynasty, carries 131 records on the Kepler Supernova 1604; all of them are given in the present report. Among them 112 records are detailed descriptions about the observed brightness variation over the period from October 13, 1604 (the 37th year of King Sunjo) to April 23, 1605. On July 14, 1605, an addendum is given as a final assessment of the guest star incidence. Since the apparent brightness, size and position are carefully described as compared to bright planets and stars, these records are ideal for retrieving light curve of the Kepler Supernova over the seven month period. Simple procedures are suggested for the derivation of light curve.

  • PDF

New Offset-compensation Technique for Capacitive MEMS-Sensor (정전형 MEMS 검출기의 새로운 Offset 보상 방법)

  • Min, Dong-Ki;Jeon, Jong-Up
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1896-1898
    • /
    • 2001
  • An offset problem caused by the static parasitic capacitors is analyzed and then some techniques to reduce their effect on the capacitive position sensor are presented. Also new offset compensation technique is proposed that by adjusting the magnitudes of the modulating signals independently, the charge imbalance between electrodes caused by the parasitic capacitors is eliminated without sensor gain variation. Simulation results are given to validate the proposed compensation technique.

  • PDF