• Title/Summary/Keyword: Portable medical device

Search Result 79, Processing Time 0.021 seconds

Bio-Signal Acquisition System Using Mobile Device (휴대용 개인 정보 단말기를 이용한 생체신호 획득 시스템)

  • Kim Hyung-Bae;Kwon Man-Jun;Cha Eun-Jong;Chun Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.349-354
    • /
    • 2005
  • In this paper, we propose a mobile telemedicine system that acquires more easily and analyzes individual's bio-signal using PDA. It is not easy for modern people who live busily, disabled patients, or old people to visit hospital. The major goal of this study is to implement the mobile telemedicine systems that the captured bio-signal from remote hospital or other medical treatment device is transmitted via Bluetooth module in ubiquitous environment, PDA with built-in Bluetooth module receives its data and displays on the screen in various form. By implemented systems, it is possible to compare current bio-signal with historical bio-signal and analyze bio-signal, and it is able to make a self diagnosis and it is available to be examined and treated remote diagnosis by sending stored bio-signal to a medical doctor.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Energy Harvesting from Bio-Organic Substance Using Microbial Fuel Cell and Power Conditioning System (미생물 연료 전지와 전력 조절 시스템을 이용한 생체 유기 물질로부터의 전력 생산)

  • Yeo, Jeongjin;Yang, Yoonseok
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.242-247
    • /
    • 2017
  • This study presents a bio-chemical energy harvesting system which can generate electric power from bioorganic substance contained in vermicompost. It produced electricity by inoculating microbial fuel cell(MFC) with earthworm-composted food waste. The generated electricity was converted into usable voltage level for mobile electronics through power conditioning circuits. The implemented prototype showed $200{\mu}W$ of maximum output electric power, which successfully supplied a beacon device which continuously transmitted data to nearby smartphone without a battery. The proposed system can help develop portable or bio-mimetic energy supply for sustainable use with further improvement.

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

Develop 3D Prostate Cancer Visualization Tool in Smart Care System (스마트 케어 시스템에서의 3차원 전립선 암 가시화 도구 개발)

  • Ahn, Byung Uk;Shin, Seung Won;Choi, Moon Hyung;Jung, Seung Eun;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2016
  • In Korea, prostate cancer accounted for generating growth rate second the following thyroid cancer, because of western dietary habits. Survival rate of prostate cancer after clinical behavior is changed depend on follow-up management. A telemedicine have been applied to replacement of medical specialist in rural area, and a quick reaction to emergency situation. Our study developed prostate 3-dimensional (3D) visualization program and designed prostate aftercare system architecture, called smart care, using a device that can access the Internet. Region of interest (ROI) in prostate was manually segmented by physicians and visualized to 3D objects and sent to PACS Server as DICOM images. So, medical personnel could confirm patients' data along with 3D images not only PACS system, but also portable device like a smart phone. As a result, we conducted the aftercare service to 98 patients and visualize 3D prostate images. 3D images had advantage to instinctively apprehend where lesion is and make patients to understand state of their disease easily. In the future, should conduct an aftercare service to more patients, and will obtain numerical index through follow-up study to an accurate analysis.

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.

Design a Portable Biomedical Signal Measuring System for U-Health (U-Health를 위한 휴대형 생체신호 측정 시스템 설계)

  • Lee, Han-Wook;Kim, Sung-Hoo;Jeong, Won-Geun;Lee, Ju-Won;Jang, Doo-Bong;Lee, Gun-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • U-Health is abbreviated from ubiquitous Health. Its final aim is "to improve the quality of life. To realize it, it is needed to generalize IT infrastructure such as the development of information-technology and construction of network. It is guaranteed to get medical care benefits unconsciously every time and everywhere based on this system. In this study, the environment of unconscious measurement was set up through ultra-violet instead of the existing Probe to wear with finger to follow this. TFT-LCD was included into module for display. U-Healthcare focused on the minimization and portable characteristic through the designed Zigbee communication module. Handled healthcare device was developed based on the U-Healthcare.

  • PDF

Development of Automatic Segmentation Algorithm of Intima-media Thickness of Carotid Artery in Portable Ultrasound Image Based on Deep Learning (딥러닝 모델을 이용한 휴대용 무선 초음파 영상에서의 경동맥 내중막 두께 자동 분할 알고리즘 개발)

  • Choi, Ja-Young;Kim, Young Jae;You, Kyung Min;Jang, Albert Youngwoo;Chung, Wook-Jin;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.100-106
    • /
    • 2021
  • Measuring Intima-media thickness (IMT) with ultrasound images can help early detection of coronary artery disease. As a result, numerous machine learning studies have been conducted to measure IMT. However, most of these studies require several steps of pre-treatment to extract the boundary, and some require manual intervention, so they are not suitable for on-site treatment in urgent situations. in this paper, we propose to use deep learning networks U-Net, Attention U-Net, and Pretrained U-Net to automatically segment the intima-media complex. This study also applied the HE, HS, and CLAHE preprocessing technique to wireless portable ultrasound diagnostic device images. As a result, The average dice coefficient of HE applied Models is 71% and CLAHE applied Models is 70%, while the HS applied Models have improved as 72% dice coefficient. Among them, Pretrained U-Net showed the highest performance with an average of 74%. When comparing this with the mean value of IMT measured by Conventional wired ultrasound equipment, the highest correlation coefficient value was shown in the HS applied pretrained U-Net.

The Reliability and Validity of a Portable Hand-held Spirometer for the Measurement of Various Lung Functions in Healthy Adults

  • Merve Nur Uygun;Jun-Min Ann;Byeong-Hyeon Woo;Hyeon-Myeong Park;Ha-Im Kim;Dae-Sung Park;In-Beom Jeong
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.179-186
    • /
    • 2024
  • Objective: This study aims to assess the reliability and validity of the new hand-held spirometer as a potential substitute for traditional pulmonary function testing (PFT) devices. Design: Cross-sectional study. Methods: In this study, thirty healthy adults underwent spirometry using both the new hand-held spirometer and the MIR spirometer, which is a standard PFT device. Parameters including peak expiratory flow (PEF), forced expiratory volume in one second (FEV1), and forced vital capacity (FVC) were measured and analyzed for validity and reliability. Inter-rater reliability and validity were evaluated through 95% limits of agreement (LOA) and intraclass correlation coefficients (ICC). Statistical analyses, including the Bland-Altman plots and the ICC, were utilized to assess agreement between the two devices. Results: The new hand-held spirometer exhibited a good agreement with intra-class coefficient (ICC [2,1]) ranging 0.762 to 0.956 and 95% LOA of -1.94 to 1.80 when compared with MIR. The test-retest reliability of the hand-held spirometer analyzed using - ICC [2,1] demonstrated a good level of consistency (ICC [2,1] =0.849-0.934). Conclusions: In conclusion, the study aimed to assess the potential of the new hand-held spirometer as a viable alternative to traditional PFT devices, with a specific focus on its reliability and validity in spirometric measurements. The new hand-held spirometer exhibited good test-retest reliability across all measured variables, suggesting its potential as a valid and reliable tool for simultaneous PFT measurements.

The Relationship Between Obstructive Sleep Apnea and Cartotid Artery Atherosclerosis (폐쇄성수면무호흡과 목동맥동맥경화증의 상관관계)

  • Cho, Jae-Wook;Kim, Yong-Wan;Lee, Hyun-Soon;Jeon, Doo-Soo;Kim, Yun-Seong;Jung, Dae-Soo
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.2
    • /
    • pp.54-58
    • /
    • 2009
  • Background: Obstructive sleep apnea (OSA) is associated with several cardiovascular diseases. However, the mechanisms are not completely understood. The measure of common carotid artery intima-media thickness (IMT) has been extensively used as an early marker of atherosclerosis. The aim of this study was to test the hypothesis that early signs of atherosclerosis are present in patients with OSA and correlate with OSA severity Methods: Eleven male patients with OSA were studied by using full standard overnight polysomnography and high-definition echo-tracking device to measure intima-media thickness and carotid artery diameter. Eight healthy volunteers matched for age and sex were studied by portable respiratory monitoring device. All participants were free of hypertension, diabetes, and were not on any medications. Patients with OSA were naive to treatment. Results: All patients and normal controls were male. There was no significant difference of age between patients and controls ($48.4{\pm}8.85$ and $48.0{\pm}9.77$). Significant differences existed between control subjects and patients with mild to moderate and severe OSA (apnea-hypopnea index, $1.51{\pm}1.15$ and $38.51{\pm}19.13$ respectively) in intima-media thickness ($0.59{\pm}0.064$ and $0.93{\pm}0.16$; P=0.0023), and carotid diameter ($5.79{\pm}0.44$ and $6.47{\pm}0.51$; P=0.0227). Multivariate analyses showed that the apnea-hypopnea index correlated independently with intima-media thickness and carotid diameter (r=0.79, P=0.0008, and r=0.47, P=0.0482). Conclusions: Middle-aged patients with OSA who are free of overt cardiovascular diseases have early signs of atherosclerosis, which further supports the hypothesis that OSA plays an independent role in atherosclerosis progression.

  • PDF