• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.026 seconds

A Study on Weld Defect and Their Alternatives during Lap Welding of AZ31B Magnesium Alloy by Pulsed Nd: YAG Laser (Nd:YAG 펄스 레이저를 이용한 AZ31B 마그네슘 합금의 겹치기 용접에서 발생하는 용접결함과 그 대책에 대한 연구)

  • Kim, Jong-Do;Lee, Jung-Han;Kim, Young-Sik
    • Journal of Welding and Joining
    • /
    • v.29 no.3
    • /
    • pp.82-88
    • /
    • 2011
  • With a tendency for the application of thin magnesium alloy plates in portable electronic equipment such as cell phone and notebook PC, there is a requirement to develop a welding technology for the lap welding of these thin magnesium alloy. This paper presents the single pulsed laser welding of AZ31B magnesium alloy. The effects of fiber types and parameters such as peak power and pulse width on laser weldability were investigated. The results show that weld defects, especially solidification crack, were always generated in the weld. These defects couldn't be controlled by the simple square pulse, but could be improved through the application of variable pulse. It is because that variable pulse has effect of solidification delay by dropping peak power gradually.

A Calibration Study of Therapeutic Ultrasound Equipment Output Intensity Accuracy

  • Yuk, Goon-Chang;Ahn, Sang-Ho;Park, So-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.37-42
    • /
    • 2011
  • Purpose: The principal objective of this study was to evaluate the power output of ultrasound in Korean clinics and compare the value with Korean and global standards. Methods: A total of 69 units were measured for ultrasound power output. The normal range of power output level was ${\pm}30%$ of the output set according to KFDA standards. Device model, manufacturer, ERA, and BNR were obtained via simple questionnaires. A portable ultrasound power meter was used for output measurement. Results: 37 machines, with reported ERA values, were assessed for power output per unit area. Of these machines, 13 (37.14%) were considered to be compliant with US FDA standards at 0.5, 1.0, 1.5, $20W/cm^2$ and 18 (51.43%) were considered within KFDA standards. The remainder of the machines were outside the standard error and evidenced irregular output levels, even though most of them were the same model. Conclusion: Appropriate ultrasound intensity is incredibly important for safety and effective use. Therefore, the KFDA standards regarding ultrasound may require revision in light of global standards, including BNR and ERA additionally, attention should be paid to regular calibration for safe use in clinical practice.

Prediction of Soil Distribution Using Digital Terrain Indices (수치 지형인자를 활용한 토양수분분포 예측)

  • Lee, Hak-Su;Kim, Gyeong-Hyeon;Han, Ji-Yeong;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.4
    • /
    • pp.391-401
    • /
    • 2001
  • Several curvature parameters, solar radiation parameter and topographic flow generation parameters have been summarized and calculated to predict the spatial distribution of soil moisture content. The spatial distribution of soil moisture data can be obtained using Global Positioning System(GPS) and portable soil moisture monitoring equipment, Theta-Probe. Correlation analysis has been performed between the parameters of soil moisture prediction and measured data of soil moisture. Multiple regression analysis of soil moisture prediction shows the potential capability and limitations of existing methods of digital terrain analysis.

  • PDF

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.

Reliability and Validity of Knee Joint Angles of the Elderly Measured Using Smartphones

  • Lee, Daehee;Han, Seulki
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.3
    • /
    • pp.2107-2112
    • /
    • 2020
  • Background: With the increasing elderly population, the need for gait analysis of these elderly individuals is also increasing. Most devices are costly and not portable; however, smartphones using built-in sensors capable of measuring motion and are easily available. Objectives: To examine the reliability and validity of knee joint angles of the elderly using smartphone measurements during walking. Design: Quasi-experimental research. Methods: Sixteen elderly people, aged 65+ and living in Daejeon and Chungbuk, South Korea, participated in the study. Electrogoniometers and smartphones were attached to the thigh and the side and front of the shank of each subject, respectively, using double-sided tape, an arm band, and an elastic band. Each subject completed two sets of at least seven gait cycles (14 steps). Results: Both the smartphones and electrogoniometers exhibited high agreement in terms of their primary and secondary measurements (ICC>.75). The agreement between the smartphones and electrogoniometers was also high in terms of both the primary and secondary measurements (ICC<.60). Conclusion: These results indicate that smartphones can be costly equipment cannot, even though they cannot completely replace existing clinical-grade devices. Their utility is emphasized herein for measuring knee joint angles of the elderly during walking.

Effect of Suprahyoid Muscle Resistance Exercise Using Kinesio Taping on Suprahyoid Muscle Thickness in Patients with Dysphagia after Subacute Stroke

  • Lee, Myunglyeol;Kim, Jinuk;Oh, Donghwan;Lee, Kuija
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.3
    • /
    • pp.2135-2139
    • /
    • 2020
  • Background: Recently, a new method of dysphagia rehabilitation using Kinesio taping (KT) has been attempted and demonstrated an immediate increase in the activation of the suprahyoid muscle during swallowing in healthy adults. Objectives: To investigate the effect of dysphagia rehabilitation using KT on the thickness change of the suprahyoid muscle in patients with dysphagia after stroke. Design: Two-group pre-post design. Methods: In this study, 20 patients with dysphagia after stroke were enrolled and assigned to the experimental and control groups. The experimental group applied KT to the front of the neck and repeatedly swallowed against the tension of the tape. On the other hand, the control group performed repeated swallowing without applying KT. Patients in both groups had swallowed 50 times a day/5 times a week for 4 weeks. For evaluation, the volume of the geniohyoid, mylohyoid, and digastric muscle was measured before and after the intervention using portable ultrasound equipment. Results: As a result of comparing the two groups after the intervention, the experimental group showed more volume increase in mylohyoid (P<.05) and digastric muscle (P<.05) than the control group. Conclusion: This study proved that suprahyoid muscle resistance exercise using KT is effective in increasing the volume of the suprahyoid muscle.

A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube (개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발)

  • 이종수;신창민;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.479-486
    • /
    • 2001
  • Spirometer is a medical equipment which diagnoses respiratory function by measuring 9as volume across Patient's lunes through airway. Because a little overdose of anesthesia medicine can take away Patient's life in the ventilator for a surgical operation. an exact measurement of respiring volume is very important. This Paper Presented an exact flow volume calculation method from factors having an influence on measurement and introduced a spirometry system for an anesthesia ventilato. This system, using differential Pressure sensor measured flow by mutual relation with Pressure. temperature. gas density and linearization from the 2nd order characteristics of differential pressure with flow.

  • PDF

Preprocessor Implementation of Open IDS Snort for Smart Manufacturing Industry Network (스마트 제조 산업용 네트워크에 적합한 Snort IDS에서의 전처리기 구현)

  • Ha, Jaecheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1313-1322
    • /
    • 2016
  • Recently, many virus and hacking attacks on public organizations and financial institutions by internet are becoming increasingly intelligent and sophisticated. The Advanced Persistent Threat has been considered as an important cyber risk. This attack is basically accomplished by spreading malicious codes through complex networks. To detect and extract PE files in smart manufacturing industry networks, an efficient processing method which is performed before analysis procedure on malicious codes is proposed. We implement a preprocessor of open intrusion detection system Snort for fast extraction of PE files and install on a hardware sensor equipment. As a result of practical experiment, we verify that the network sensor can extract the PE files which are often suspected as a malware.

The Noise Removal Methode of Partial Discharge Signal (부분방전 신호 검출 시 노이즈 제거방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1436-1441
    • /
    • 2016
  • Currently, partial discharge diagnosis in the field of prevention applied technology and diagnostic equipment is a possible strong limit to remove the noise generated by external or internal I still have one unreliable diagnosis. This technology is the noise removal from signal the time lag analysis algorithms technique is applied by a fundamental. Increasing the reliability in terms of technology spectrum frequence of analysis method for by applying the acquisition through the position of the frequency content and sources of traffic lights partial discharge of the acquisition of signal analysis to judge whether a way diagnosis the environment of the scene, and conditions. Partial discharge signal and make the discharge while building blocks were found through the Analysis. Spectrum frequence of Analysis and wide discharge part, to be more precise, in line with the various functions, including the analysis technique band. Diagnosis and comes up with advanced technology that can detect the presence of a position. This method is portable single device developed for maintenance and mobility and ease and convenience of getting caught by discharge of the pattern analysis and position detection method suitable for a new diagnosis will suggest.

A Useful Technique for Measuring the 3-dimensional Positioning of a Rotating Object (회전체의 효과적인 3차원 위치오차 측정방법)

  • Lee, Eung-Seok;Wi, Hyeon-Gon;Jeong, Ju-No
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.918-924
    • /
    • 1997
  • A method for measuring the accuracy of rotating objects was studied. Rotating axis errors are significant; such as the spindle error of a manufacturing machine which results in the surface roughness of machined work pieces. Three capacitance type displacement sensors were used to measure the rotating master ball position. The sensors were mounted to the three orthogonal points on the spindle axis. The measurement data were analyzed and shown for rotating spindle accuracy, not only for average roundness error but also for spindle volumetric positional error during the revolutions. This method is simple and economical for industrial field use with regular inspection of rotating machines using portable equipment. Measuring and analyzing time using this method takes only a couple of hours. This method can also measure microscopic amplitude and 3-dimensional direction of vibrating objects.