• Title/Summary/Keyword: Portable System

Search Result 1,354, Processing Time 0.026 seconds

Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander (전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현)

  • Oh Do-Chang;Choi Dong-Hyuk;Lee Hong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System (휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정)

  • 강나루;우영아;차봉수;이현철;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Development of a Portable Auger System for Rough Rice Handling in Bulk (미곡(米穀)의 산물이송(散物移送)을 위한 이동식 오거의 개발(開發))

  • Chang, D.I.;Chang, K.S.;Kim, J.H.;Kim, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.2
    • /
    • pp.115-122
    • /
    • 1989
  • The objective of this study was to develop a portable auger for handling rough rice in bulk. For this purpose, a system analysis was taken for the systems of harvesting, drying, storage and transportation of rough rice and an optimal handling capacity of portable auger was determined. Then a portable auger of which capacity is 9.2 $m^3/h$ (Indica type rough rice, 19.5%, w.b.) was designed and manufactured by design requirements and tested. Test results showed that the performance of portable auger developed satisfied most design requirements.

  • PDF

A Portable Surface Plasmon Resonance Biosensor for Rapid Detection of Salmonella typhimurium

  • Nguyen, Hoang Hiep;Yi, So Yeon;Woubit, Abdela;Kim, Moonil
    • Applied Science and Convergence Technology
    • /
    • v.25 no.3
    • /
    • pp.61-65
    • /
    • 2016
  • Here, the rapid detection of Salmonella typhimurium by a portable surface plasmon resonance (SPR) biosensor in which the beam from a diode laser is modulated by a rotating mirror is reported. Using this system, immunoassay based on lipopolysaccharides (LPS)-specific monoclonal anti-Salmonella antibody was performed. For the purpose of orientation-controlled immobilization of antibodies on the SPR chip surface, the cysteine-mediated immobilization method, which is based on interaction between a gold surface and a thiol group (-SH) of cysteine, was adopted. As a result, using the portable SPR-based immunoassay, we detected S. typhimurium in the range from 10^7 CFU/mL to 10^9 CFU/mL within 1 hour. The results indicate that the portable SPR system could be potentially applied for general laboratory detection as well as on-site monitoring of foodborne, clinical, and environmental agents of interest.

Remote Emergency Stop System to Improve Safety of Automated Driving Vehicle (자동주행차량의 안전성 향상을 위한 원격비상정지시스템)

  • Ryoo, Young-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.3
    • /
    • pp.194-198
    • /
    • 2015
  • In this paper, a remote emergency stop system to improve the safety of an automated driving vehicle is proposed. One of the most serious problems of the previous wireless remote emergency system is that it does not work when the wireless channel is damaged in case of an emergency because it is composed of a single communication channel. Therefore, the proposed remote emergency stop system composed of a portable wireless remote system and a stationary wireless remote system is designed and the remote emergency stop system for automated driving vehicles is developed. By applying it to an automated driving vehicle to check it's performance, the wireless remote system is tested. Emergency stops using the portable wireless remote system is tested when the stationary wireless remote system is disconnected. Also, emergency stops using the stationary wireless remote system are tested when the portable wireless remote system is disconnected. The results of the emergency stop test show a satisfactory performance.

Analysis of Interference Impacts by UWB System to WiBro Systems

  • Yoon Young-Keun;Jin Rong-Reon;Kim Kyung-Seok;Choi Ik-Guen
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.197-203
    • /
    • 2005
  • This paper evaluates the impacts for interference from UWB system, and determines the tolerable UWB power spectral density(PSD) to the new deploying system, which is called a portable internet service in Korea. It also proposes the interference analysis scheme that can evaluate the characteristics of the performance degradation for portable internet service according to the emission power of UWB systems at the specified frequency bands. The proposed scheme includes a multi-rate and data service environments to deal with interference to portable internet service. It is obtained from simulation results that the transmission PSD of UWB systems should be rigidly restricted by less approximately 10 ${\~}$ 20 dB than FCC provisional limit for coexistence between UWB and portable internet service already allocated at 2.3 GHz frequency bands in Korea.

Development of Portable Atmospheric Environment Measurement System using Low Power Wireless Communication

  • Chae, Soohyeon;Kim, Hack-Yoon;Gim, Jangwon
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.1
    • /
    • pp.99-109
    • /
    • 2020
  • As environmental pollution has become severe due to the rapid increase in pollutant generation in the air, measurement, collection, and analysis of atmospheric environment information plays an important role. However, it is difficult to measure the high-resolution and real-time atmospheric environment of the cities and tourist spots with high population mobility only by measuring equipment of stationary measuring stations. Therefore, this paper proposes a portable atmospheric environment measurement system for real-time measurement and monitoring of atmospheric environment information. The proposed system is a portable client with a low-power wireless communication method. It is possible to reliably transmit and receive the measured data through a multi-threaded server to monitor the trend of pollutants in the air in real-time.

Implementation of a Portable ECG Recorder Using Wire and Wireless Communication Network (유.무선 통신망을 이용한 휴대용 심전도계 구현)

  • 김상득;배용욱;박준홍;구자헌;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.85-88
    • /
    • 2001
  • In this paper, we designed a portable ECG Recorder which can transmit collected ECG data using wire and wireless communication network. The portable ECG recorder is characterized by the small-sized and the low-power consumption. The ECG data is transmitted to a hospital using internet or PSTN. We designed the protocol in order to transmit safely The portable ECG recording system will contribute largely to telemedicine for a cardiac patient.

  • PDF

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF