• 제목/요약/키워드: Port system

검색결과 3,951건 처리시간 0.034초

키워드 자동 생성에 대한 새로운 접근법: 역 벡터공간모델을 이용한 키워드 할당 방법 (A New Approach to Automatic Keyword Generation Using Inverse Vector Space Model)

  • 조원진;노상규;윤지영;박진수
    • Asia pacific journal of information systems
    • /
    • 제21권1호
    • /
    • pp.103-122
    • /
    • 2011
  • Recently, numerous documents have been made available electronically. Internet search engines and digital libraries commonly return query results containing hundreds or even thousands of documents. In this situation, it is virtually impossible for users to examine complete documents to determine whether they might be useful for them. For this reason, some on-line documents are accompanied by a list of keywords specified by the authors in an effort to guide the users by facilitating the filtering process. In this way, a set of keywords is often considered a condensed version of the whole document and therefore plays an important role for document retrieval, Web page retrieval, document clustering, summarization, text mining, and so on. Since many academic journals ask the authors to provide a list of five or six keywords on the first page of an article, keywords are most familiar in the context of journal articles. However, many other types of documents could not benefit from the use of keywords, including Web pages, email messages, news reports, magazine articles, and business papers. Although the potential benefit is large, the implementation itself is the obstacle; manually assigning keywords to all documents is a daunting task, or even impractical in that it is extremely tedious and time-consuming requiring a certain level of domain knowledge. Therefore, it is highly desirable to automate the keyword generation process. There are mainly two approaches to achieving this aim: keyword assignment approach and keyword extraction approach. Both approaches use machine learning methods and require, for training purposes, a set of documents with keywords already attached. In the former approach, there is a given set of vocabulary, and the aim is to match them to the texts. In other words, the keywords assignment approach seeks to select the words from a controlled vocabulary that best describes a document. Although this approach is domain dependent and is not easy to transfer and expand, it can generate implicit keywords that do not appear in a document. On the other hand, in the latter approach, the aim is to extract keywords with respect to their relevance in the text without prior vocabulary. In this approach, automatic keyword generation is treated as a classification task, and keywords are commonly extracted based on supervised learning techniques. Thus, keyword extraction algorithms classify candidate keywords in a document into positive or negative examples. Several systems such as Extractor and Kea were developed using keyword extraction approach. Most indicative words in a document are selected as keywords for that document and as a result, keywords extraction is limited to terms that appear in the document. Therefore, keywords extraction cannot generate implicit keywords that are not included in a document. According to the experiment results of Turney, about 64% to 90% of keywords assigned by the authors can be found in the full text of an article. Inversely, it also means that 10% to 36% of the keywords assigned by the authors do not appear in the article, which cannot be generated through keyword extraction algorithms. Our preliminary experiment result also shows that 37% of keywords assigned by the authors are not included in the full text. This is the reason why we have decided to adopt the keyword assignment approach. In this paper, we propose a new approach for automatic keyword assignment namely IVSM(Inverse Vector Space Model). The model is based on a vector space model. which is a conventional information retrieval model that represents documents and queries by vectors in a multidimensional space. IVSM generates an appropriate keyword set for a specific document by measuring the distance between the document and the keyword sets. The keyword assignment process of IVSM is as follows: (1) calculating the vector length of each keyword set based on each keyword weight; (2) preprocessing and parsing a target document that does not have keywords; (3) calculating the vector length of the target document based on the term frequency; (4) measuring the cosine similarity between each keyword set and the target document; and (5) generating keywords that have high similarity scores. Two keyword generation systems were implemented applying IVSM: IVSM system for Web-based community service and stand-alone IVSM system. Firstly, the IVSM system is implemented in a community service for sharing knowledge and opinions on current trends such as fashion, movies, social problems, and health information. The stand-alone IVSM system is dedicated to generating keywords for academic papers, and, indeed, it has been tested through a number of academic papers including those published by the Korean Association of Shipping and Logistics, the Korea Research Academy of Distribution Information, the Korea Logistics Society, the Korea Logistics Research Association, and the Korea Port Economic Association. We measured the performance of IVSM by the number of matches between the IVSM-generated keywords and the author-assigned keywords. According to our experiment, the precisions of IVSM applied to Web-based community service and academic journals were 0.75 and 0.71, respectively. The performance of both systems is much better than that of baseline systems that generate keywords based on simple probability. Also, IVSM shows comparable performance to Extractor that is a representative system of keyword extraction approach developed by Turney. As electronic documents increase, we expect that IVSM proposed in this paper can be applied to many electronic documents in Web-based community and digital library.

한국 연근해 불법어업의 지도 단속 실태 (Actual Results on the Control of Illegal Fishing in Adjacent Sea Area of Korea)

  • 이상조;김진건
    • 수산해양교육연구
    • /
    • 제10권2호
    • /
    • pp.139-161
    • /
    • 1998
  • 한국 연근해 불법어업의 단속에 관한 법적규정과 그 체제 및 절차를 검토하고, 해양수산부 어업지도선이 1994년부터 1996년까지 수행한 불법어업자 처리상황대장을 토대로 하여 불법어업이 많은 시기, 어장, 어업의 종류, 경영자의 주소지, 범칙 사항 등에 관하여 분석한 결과를 요약하면 다음과 같다. 1. 해양수산부 어업지도선은 불법어업 지도 단속을 위하여 1994년에는 17척이 총 292회, 2,726일간 출동하여 총 826건을 단속하였으며, 1995년에는 18척이 총 333회, 3,060일간 출동하여 총 1,086건을 단속하고, 1996년에는 19척이 총 330회, 3,126일간 출동하여 총 933건을 단속하였다. 2. 불법어업의 어업시기별 단속건수는 대체적으로 4월부터 9월까지의 시기에 집중적으로 많이 단속되었으나 1994년에 비하여 1995년, 1996년으로 갈수록 이 시기 이외의 다른 시기에도 많이 단속되는 등 그 단속건수가 연중 단속체제로 분산된 경향이었다. 3. 불법어업이 첫 번째로 가장 많이 단속된 해역은 충무항 근해의 남해 중부해역으로서 1994년과 1995년에 전체 단속건수의 약 36%를 차지하던 것이 1996년에는 약 51%로 증가하였고, 두 번째로 많은 것은 여수항 근해의 남해 서부해역으로서 1994년에 약 18%이던 것이 1995년에는 약 27%, 1996년에는 약 24%를 차지하였으며, 세 번째는 부산항 근해의 남해 동부해역으로서 1994년에 약 23%이던 것이 1995년에 약 18%, 1996년에 약 13%로 점점 감소하는 경향이었다. 4. 불법어업의 업종별 단속건수는 소형기선저인망어업이 가장 많은 업종으로서 1994년에 전체 단속건수의 약 81%, 1995년에 약 82%, 1996년에 약 95%를 차지하는 등 해를 거듭할수록 증가하였으며, 다음으로는 중형기선저인망으로서 1994년과 1995년에 각각 약 7%를 차지하고, 1996년에는 약 4%로 다소 감소하였고, 근해트롤은 1994년에 약 4%, 1995년에 약 2%, 1996년에 약 2%를 차지하는 등 점점 감소하는 경향이었다. 5. 불법어업의 경영자 주소지별 단속건수는 부산시가 첫 번째로 가장 많은 주소지로서 1994년에 전체 단속건수의 약 51%, 1995년에 약 41%, 1996년에 약 33%를 차지하는 등, 점점 감소하였고, 두 번째는 전납으로서 1994년에 약 24%, 1995년과 1996년에 각각 약 29%로 답보상태이며, 세 번째는 경남으로서 1994년에 약 16%였던 것이 1995년에 약 20%, 1996년에 약 35%를 차지하는 등 점점 증가하는 경향이었다. 6. 불법어업의 범칙 사항별 단속건수는 수산업법 제 57조에서 규정한 무면허, 무허가, 무신고 어업이 가장 많으며, 전체 단속건수의 약 56~64%를 차지하고, 두 번째는 수산자원 보호령 제23조에서 규정한 어선 어구의 제한 또는 금지를 위반한 어업으로서 전체 단속건수의 약 21~36%를 차지하였으며, 이상의 경우는 모두 그 단속건수가 증가하였다. 7. 신해양질서에 따른 배타적 경제수역(EEZ)선정 및 총어획허용량(TAC)제도에 능동적으로 대처하기 위하여, 첫째는 불법어업의 지도 단속체계와 기능을 강화하여 강력한 단속을 실시하고, 둘째는 불법어업자에 대한 처벌을 강화함과 동시에 지원사업에서 배제하는 경제적 불이익을 받도록 하며, 셋째는 정부의 강력한 불법어업의 근절의지와 지도 계몽으로 어업인들이 자율적으로 불법어업을 근절하려는 캠페인을 확산해 가야할 필요가 있다. 8. 최근 3개년간 수산해양부 어업지도선의 불법어업 지도 단속실적을 분석한 결과에 따라 불법어업이 많은 시기, 해역, 업종, 경영자의 주소지, 범칙 사항별로 불법어업의 근절을 위해 해상은 물론이고 육상에서도 관계기관이 연계하여 입체적인 지도 단속을 실시할 필요가 있다.

  • PDF

실습선 한바다호 주기관 배기가스 배출물질 특성 고찰에 관한 연구 (A Study on the Characteristics Measurement of Main Engine Exhaust Emission in Training Ship HANBADA)

  • 최정식;이상득;김성윤;이경우;천강우;남연우;정균식;박상균;최재혁
    • 해양환경안전학회지
    • /
    • 제19권6호
    • /
    • pp.658-665
    • /
    • 2013
  • 본 연구에서는 국제해사기구(IMO)의 뜨거운 관심분야로 부상되고 있는 선박기인 입자상물질(PM)과 오염물질 배출에 관하여 한국해양대학교 실습선 한바다호를 이용하여 계측하였다. 특히, PM은 TEM 그리드를 이용해 채취하고 전자현미경으로 구조를 파악하였으며, NOx, $CO_2$, CO 등의 배기가스는 연소가스분석기(PG-250A, HORIBA)를 이용해 측정하였다. 본 연구의 결과는 다음과 같다. 1) 선박이 항구에서 출항할 때, Bunker Change로 인한 PM 배출량은 최대 30 % 정도 차이가 있었다. 2) 정속 운항을 하면서 Bunker-A에서 L.R.F.O(3 %)로 변경할 때 측정한 PM 배출량은 $1.34mg/m^3$, L.R.F.O(3 %)로 고정해 측정한 PM 배출량은 $1.19mg/m^3$, L.R.F.O(3 %)만 사용하며 주기관 회전수를 20 % 증가시키면서 계측한 PM 배출량은 $1.40mg/m^3$ 이었다. 또한, 저질유(L.R.F.O(3 %))로 변경시 CO 농도는 약 16 % 증가하는데 비해 RPM을 20 % 상승시킨 경우에는 152 % 이상 급격한 증가를 보였다. 이러한 결과로부터 배기가스 배출의 증가는 연료유종의 영향도 있으나, RPM의 변화에 민감하다는 것을 알 수 있었다. 3) TEM 그리드로 채취한 PM은 약 $4{\sim}10{\mu}m$ 정도의 다양한 입경을 가지는 다공질 응집체 형상의 구조인 것으로 확인하였다.

생물증강법을 이용한 오염해양준설토의 환경친화적 정화 및 재활용 (Eco-friendly remediation and reuse for coastal dredged materials using a bioaugmentation technology)

  • 김인수;하신영;고성철
    • 미생물학회지
    • /
    • 제51권4호
    • /
    • pp.374-381
    • /
    • 2015
  • 국내의 경우 항만과 연안해역 준설로 인하여 연간 수 천만톤 이상 준설토사가 발생하며 매년 증가하고 있으나, 대부분 투기장에 장기간 방치되며, 더구나 2012년부터 런던협약에 의해 해양투기가 금지되고 있어 환경친화적인 준설토처리 및 재활용기술개발이 시급하다. 준설토 재활용기술에서는 중간처리과정후 발생하는 현탁수(유기물과 중금속 함유 $10{\mu}m$ 미만 미세오염퇴적물 포함)의 처리가 필요한데 현재 이 기술은 연구되어 있지 않다. 본 연구에서는 복합유용미생물제제(BM-S-1)을 이용하여 미세해양오염퇴적물($10{\mu}m$ 이하 입자)내 오염되어 있는 유기물질, 영양염류 및 중금속을 정화하여 배출함으로써 오염퇴적물 정화처리수 방류수질 기준을 충족하고자 하였다. BM-S-1 복합미생물제제를 이용한 해양준설토의 친환경정화시스템으로서 일일 50 L 처리용량의 Lab scale 실험장치를 HRT 6.5일, BOD 용적부하 $0.2-0.6kg/m^3{\cdot}day$의 조건으로 생물반응기를 100일 이상 운전하였다. SCOD, T-N 및 T-P의 제거효과는 각각 96.1%, 92.0% 및 79.0%로 나타나 오염미세퇴적토 내의 유기물의 처리효과가 매우 양호하였다. 또한 몇 가지의 중금속(Zn, Ni 및 Cr) 처리에도 효과적이었다. 아울러 물리적으로 분리하기 어려운 $10{\mu}m$ 이하의 미세토양의 고액분리가 가능함을 확인하였다. 미생물군집구조를 분석한 결과 Flavobacteria 및 Gammaproteobacteria 강이 매우 우점하였으며, 이들에 속한 미생물종들은 해양 내의 각종유기물(다당류, 단백질 및 기타 생물중합체)을 처리하는 것으로 알려졌다. 따라서 본 실험에서 사용된 BM-S-1 미생물제제와 처리시스템은 고농도의 염분이 함유되어있는 유기물 및 중금속 오염 해양퇴적물 정화에 효율적으로 적용가능한 것으로 판단되며, 정화, 분리된 미세해양퇴적물은 목적에 맞게 재사용 가능할 것으로 사료된다.

입자충전형 이중벽 온실에 관한 연구 (A Study on the Double-Wall Greenhouse Filled with Styrene Pellets)

  • 이석건;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.59-67
    • /
    • 1995
  • 자동단열온실시스템을 개발할 목적으로 실험용 온실의 천정과 벽체를 이중벽으로 제작하여 이중벽 내부에 단열입자를 자동으로 충전 회수할 수 있도록 시스템을 구성하여, 입자의 송풍성능, 투광성, 입자의 마모실험, 온실의 단열성능 및 차광효과를 분석한 결과를 요약하면 다음과 같다. 1. 약 2㎥의 입자를 충전 회수하는데 약 1시간 15분이 소요되었으나, 온실의 규모에 적합한 송풍기의 용량, 배기구의 면적, 충전관 및 회수관의 조절로 소요시간을 감소시킬 수 있을 것으로 판단되었다. 2. 단열입자의 회수 직후에 이중벽온실의 투광성을 객관성 있게 평가할 수 있는 10시에서 15시까지의 평균 투광율은 67%로 나타났다. 3. 입자의 충전 및 회수를 직송방식으로 하였을 때, 입자마모율이 연속 5개월 사용시 20%로 나타나, 입자의 충전 및 회수를 간접방식으로 수행하는 것이 타당한 것으로 분석되었다. 4. 겨울철 야간에 단열입자를 회수한 이중벽 온실의 내부온도는 외기온보다 평균 3.4$^{\circ}C$ 높았으나, 입자를 충전한 단열온실의 내부온도는 단열면적비가 73%일때 외기온보다 평균 6.6$^{\circ}C$ 높았고, 단열면적비가 100%일때 외기온보다 평균 13.5$^{\circ}C$ 높게 나타나 단열온실의 야간단열성능이 우수함을 알 수 있었다. 5. 일사가 양호하고 외기온이 높은 주간에 입자를 충전한 단열온실(단열면적비 100%)의 차광성능을 분석한 결과, 외기온의 평균이 36.9$^{\circ}C$일 때 온실내부온도의 평균은 3$0^{\circ}C$로 외기온보다 평균 7$^{\circ}C$ 낮게 나타나 차광효과가 크다는 사실을 알 수 있었다.

  • PDF

Electronic Portal Imaging Device(EPID)의 유용성 평가 (The evaluation of usefulness of Electronic Portal Imaging Device(EPID))

  • 이양훈;김보겸;정치훈;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.19-31
    • /
    • 2005
  • 목적 : 방사선치료 시 자세 및 치료부위의 재현성을 유지하기 위해 Port film을 통한 정도관리가 이루어져 왔으며 Mega Voltage Imaging (MVI) System(mvis)이 출현한 이후로 많은 발전을 이루어 현재는 필름과 Electronic portal Image Device(EPID)를 통한 정도관리가 함께 이루어지고 있다. 이에 본 논문에서는 현재 사용하고 있는 EPID 시스템의 소개와 amorphous silicon (aSi) type EPID가 Intersity Modulated Radiation Therapu(IMRT)에서 film dosimetry를 대체할 수 있는지에 대한 가능성을 분석하였다. 대상 및 방법 : Varian 21EX의 aSi type EPID와 Varian 6EX의 LC type EPID를 통해 FDD, Gantry 회전에 따른 재현성 분석과 EPID 출/입시 FDD에 따른 시간분석을 하였으며 Alderson Rando phantom을 이용하여 Couch & Gantry rotation에 따른 영상획득 가능범위를 분석하였다. aSi type EPID를 대상으로 Las Vegas phantom과 물팬텀으로 공간분해능과 대조도 분해능을 비교하였으며 Dynamic Multileaf collimator(DMLC)영상에 대해 저감도 측정용 필름과 EPID로 분석하여 IMRT의 정도관리 적용가능성을 시험하였다. 결과 : aSi type EPID와 LC type EPID 재현성은 출/입시 1mm 이내로 우수하게 나타났으나 Gantry 회전에 따른 재현성은 각각 ${\pm}3\;mm,\;{\pm}2\;mm$였으며 EPID의 출/입시 focus detector distance(FDD)에 따른 시간분석은 14초에서 17초로 측정되었다. Las Vegas phantom을 이용한 공간분해능과 대조도분해능 비교 시 표면과 물 팬텀 10, 20 cm 깊이에서 측정해 보았을 때 EPID가 선량율과 영상획득시간, 영상획득방법, frame수에 따라 달라짐을 확인할 수 있었으며, EPID로 영상획득 가능 범위를 분석해보면 film보다 손쉬운 측정이 가능한 것으로 나타났다. 저감도측정용 필름과 EPID를 통해 DMLC측정을 통한 IMRT 정도관리 결과 필름과 같은 값을 나타내었다. 결론 : EPID에 관한 여러 가지 평가를 통한 적절한 정보제공을 통해 EPID 사용, 관리 시 필요한 정보를 획득 할 수 있었으며 EPID를 통해 얻은 영상이 digital data라는 점에 착안해 적절한 정도관리가 어려운 IMRT의 분야에서 필름을 통한 주기적 점검의 대체수단으로 사용가능성이 있음을 알 수 있었다. 특히 point-dose 측정시 사용하는 diode나 전리조(lonization chamber)를 통해 평가하기 어려운 IMRT의 sliding window영상에 대한 적절한 평가와 MLC에서 leaf사이의 누설선량과 소조사면에서의 DMLC 움직임에 대한 정확한 평가가 기대된다.

  • PDF

위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구 (A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System)

  • 전중성;김동일;배정철
    • 한국정보통신학회논문지
    • /
    • 제4권1호
    • /
    • pp.77-88
    • /
    • 2000
  • 본 논문에서는 INMARSAT-B형 송신기에 사용되는 L-BAND(1626.5-1646.5 MHz)용 3단 가변이득 전력증폭기를 연구 개발하였다. 3단 가변이득 전력증폭기는 구동증폭단과 전력증폭단에 의해 고출력 모드일 때 +42 dBm, 중간출력 모드일 때는 +38 dBm, 저출력 모드일 때는 +34 dBm의 전력으로 증폭되며, 각각에 대해 상한 +1 dBm과 하한 2 dBm의 오차를 허용한다. 제작의 간편성 때문에 전체 3단 가변이득 전력증폭기를 크게 구동증폭단과 전력증폭단 두 부분으로 나누어 구현하였으며, 전력증폭부를 구동하기 위한 구동단은 HP사의 MGA-64135와 Motorola사의 MRF-6401을 사용하였으며, 전력증폭단은 ERICSSON사의 PTE-10114와 PTF-10021을 사용하여 RP부, 온도보상회로, 출력 조절회로 및 출력 검출회로를 함께 집적화 하였다. 이득조절은 디지털 감쇠기를 사용하였으며, 출력신호의 세기를 검출하기 위하여 20 dB 방향성 결합기를 이용하였다. 제작된 3단 가변이득 전력증폭기는 20 MHz대역폭 내에서 소신호 이득이 41.6 dB, 37.6 dB, 33.2 dB 를 얻었으며, 입출력 정재파비는 1.3:1 이하, 12 dBm의 PldB, PldB 출력레벨에서 3 dB Back off 시켰을 때 36.5 dBc의 IM3를 얻었다. 1636.5 MHz 주파수에 대해 출력전력은 43 dBm으로서 설계시 목표로 했던 최대 출력전력 20 Watt를 얻었다.

  • PDF

자동차공업의 입지와 지역발전에 관한 연구 -전남 율촌 산업단지를 사례로- (A Study on the Regional Development Effects by the Location of a New Automobile Assembly Plant -In the Case of Hyundai Motors Co. in Yulchon Industrial Complex, Chonnam Province-)

  • 이정록;이상석
    • 한국지역지리학회지
    • /
    • 제4권1호
    • /
    • pp.77-98
    • /
    • 1998
  • 본 연구는 제조업 중에서도 지역성장 및 연관산업에 대한 파급효과가 가장 큰 부문인 자동차 산업을 대상으로 새로운 조립공장 입지가 지역경제의 성장 및 발전에 미치는 영향을 경계지리학적 관점에서 논의했다. 우리 나라의 대표적 신산업지구로 발전하고 있는 광양만권의 율촌 산업단지를 사례로, 한국 최대의 자동차 조림기업인 현대자동차의 새로운 조립공장 입지가 광주 전남의 자동차산업 전반에 어떠한 영향을 미칠 것인지, 그리고 보다 미시적 수준에서 광양만권에 어떠한 파급효과를 초래할 것인지 탐색해보고자 했다. 노동집약적 특성과 자본 및 기술집약적 특성을 동시에 지니는 자동차 조립 및 부품생산 부문을 대상으로 첫째, 조립부문-부품생산부문의 공간적 비공간적 연계 특성을 규명하고 둘께, 광주 전남지역 자동차산업의 현 주소 및 이에 대한 신설 조립공장의 파급효과를 분석하며 셋째, 신설 조립공장 입지에 따른 광양만권 역내의 부품산업 발전 가능성을 전망함으로써 지역개발의 파급효과를 극대화할 수 있는 방안을 모색해보고자 하는 것이 본 연구의 목적이다.

  • PDF

지방자치단체 환경영향평가 조례 현황 분석과 협의 지침서 작성 방안 - 인천광역시 사례를 중심으로 - (Analysis of Local Government Environmental Impact Assessment (EIA) Ordinances and Preparation of Consultation Guidelinesfor EIA - A Case of Incheon Metropolitan City -)

  • 이종욱;조경두
    • 환경영향평가
    • /
    • 제31권4호
    • /
    • pp.226-240
    • /
    • 2022
  • 우리나라의 일정 규모 이상의 지방자치단체는 「환경영향평가법」 제42조에 따라 필요 시 지역 특성을 고려한 환경영향평가를 실시할 수 있다. 그러나, 다수의 지방자치단체에서 자체 환경영향평가 운영실적은 미미한 것으로 조사되었다. 이러한 문제점을 개선하기 위해서는 지방자치단체별로 상이하게 갖춰져 있는 조례 및 지침 등의 현황을 비교하여 해당 지방자치단체에 필요한 제도적 사안들을 파악할 필요가 있다. 또한, 지방자치단체 환경영향평가 절차에 대한 상세 규정 및 안내를 협의 절차 지침서(가이드 라인)에 담아 관련 정보를 제공할 필요가 있다. 본 연구에서는 인천광역시의 사례를 중심으로 하여, 여건이 비슷한 광역시·도별 지방자치단체 환경영향평가 조례 현황을 조사하고 대상사업의 종류 및 범위를 비교 분석하였다. 아울러 협의 가이드라인을 작성하고 그 과정에서 도출된 절차 흐름 및 일정 표기에 대한 개선 사항들을 제시하였다. 인천광역시의 경우 환경영향평가 조례 시행규칙 및 사후관리에 관한 세부 조항이 없어 이 부분에 대한 제도 보강이 필요한 상태였다. 그리고, 지역 환경 및 지리 여건을 고려하였을 때, 항만 건설사업, 수자원 개발사업, 철도건설사업, 국방 및 군사시설의 설치사업 등의 사업 유형에 대한 대상사업 추가 검토도 필요할 것으로 사료되었다. 인천광역시는 지방자치단체 환경영향평가 협의 업무의 실용성과 효과성 확보를 위해 협의 가이드라인 초안을 작성하였고, 그 과정에서 파악된 절차 흐름 및 일정 표기에 관한 개선 사항들을 제시하였다. 본 연구의 결과물은 지방자치단체 환경영향평가 제도를 정비하고 구체적인 절차 지침을 마련하여 운영의 효과성을 증진시키고자 하는 지방 정부에 유용한 정보를 제공할 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF