• Title/Summary/Keyword: Port range

Search Result 483, Processing Time 0.031 seconds

Comparison of Short-Term Postoperative Outcomes in Totally Laparoscopic Distal Gastrectomy Versus Laparoscopy-Assisted Distal Gastrectomy

  • Han, Gru;Park, Ji Yeon;Kim, Yong Jin
    • Journal of Gastric Cancer
    • /
    • v.14 no.2
    • /
    • pp.105-110
    • /
    • 2014
  • Purpose: The advantages of totally laparoscopic surgery in early gastric cancer (EGC) are unproven, and some concerns remain regarding the oncologic safety and technical difficulty. This study aimed to evaluate the technical feasibility and clinical benefits of totally laparoscopic distal gastrectomy (TLDG) for the treatment of gastric cancer compared with laparoscopy-assisted distal gastrectomy (LADG). Materials and Methods: A retrospective review of 211 patients who underwent either TLDG (n=134; 63.5%) or LADG (n=77; 36.5%) for EGC between April 2005 and October 2013 was performed. Clinicopathologic features and surgical outcomes were analyzed and compared between the groups. Results: The operative time in the TLDG group was significantly shorter than that in the LADG group (193 [range, 160~230] vs. 215 minutes [range, 170~255]) (P=0.021). The amount of blood loss during TLDG was estimated at 200 ml (range, 100~350 ml), which was significantly less than that during LADG, which was estimated at 400 ml (range, 400~700 ml) (P<0.001). The hospital stay in the TLDG group was shorter than that in the LADG group (7 vs. 8 days, P<0.001). One patient from each group underwent laparotomic conversion. Two patients in the TLDG group required reoperation: one for hemostasis after intraabdominal bleeding and 1 for repair of wound dehiscence at the umbilical port site. Conclusions: TLDG for distal EGC is a technically feasible and safe procedure when performed by a surgeon with sufficient experience in laparoscopic gastrectomy and might provide the benefits of reduced operating time and intraoperative blood lossand shorter convalescence compared with LADG.

Role of Postoperative Radiotherapy for Patients with Pathological Stage III Non-Small-Cell Lung Cancer after Curative Resection (근치적 절제술 후 병기3의 비소세포성 폐암에서 수술 후 방사선 치료의 역할)

  • Kim, Mi-Young;Wu, Hong-Gyun;Kim, Hak-Jae;Heo, Dae-Seog;Kim, Young-Whan;Kim, Dong-Wan;Lee, Se-Hoon;Kim, Joo-Hyun;Kim, Young-Tae;Kang, Chang-Hyun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.44-52
    • /
    • 2011
  • Purpose: To evaluate the outcomes and prognostic factors of postoperative radiotherapy (PORT) for patients with pathological stage III non-small-cell lung cancer (NSCLC) at a single institution. Materials and Methods: From 2000 to 2007, 88 patients diagnosed as having pathologic stage III NSCLC after curative resection were treated with PORT. There were 80 patients with pathologic stage IIIA and eight patients with pathologic stage IIIB in the AJCC 6th staging system. The majority of patients (n=83) had pathologic N2 disease, and 56 patients had single station mediastinal LN metastasis. PORT was administered using conventional technique (n=76) or three-dimensional conformal technique (n=12). The median radiation dose was 54 Gy (range, 30.6 to 63 Gy). Thirty-six patients received chemotherapy. Radiation pneumonitis was graded by the Radiation Therapy Oncology Group system, and other treatment-related toxicities were assessed by CTCAE v 3.0. Results: Median survival was 54 months (range, 26 to 77 months). The 5-year overall survival (OS) and disease free survival (DFS) rates were 45% and 38%, respectively. The number of metastatic lymph nodes was associated with overall survival (hazard ratio, 1.037; p-value=0.040). The 5-year locoregional recurrence free survival (LRFS) and distant metastasis free survival (DMFS) rates were 88% and 48%, respectively. Multiple stations of mediastinal lymph node metastasis was associated with decreased DFS and DMFS rates (p-value=0.0014 and 0.0044, respectively). Fifty-one relapses occurred at the following sites: 10 loco-regional, 41 distant metastasis. Grade 2 radiation pneumonitis was seen in three patients, and symptoms were well tolerated with anti-tussive medication. Grade 2 radiation esophagitis was seen in 11 patients. There were no grade 3 or more severe complications associated with PORT. Conclusion: Our retrospective data show that PORT for pathological stage III NSCLC is a safe and feasible treatment and could improve loco-regional control. The number of metastatic lymph nodes and stations of mediastinal lymph node metastasis were analyzed as prognostic factors. Furthermore, efforts are needed to reduce distant metastasis, which is a major failure pattern of advanced stage NSCLC.

Calibration Kit for 4-Port Horizontal/Vertical Probing (4-포트 수평/수직 겸용 프로브용 교정키트)

  • Kim, Taeho;Kim, Jonghyeon;Kim, Sungjun;Kim, Kwangho;Pu, Bo;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.559-575
    • /
    • 2014
  • In this paper, we propose a horizontal/vertical calibration kit for calibrating a vector network analyzer(VNA) to measure the vertical connector pin. If the conventional calibration kit is used, we should change the arm for a probe or need an assistant device and it takes a long time. In addition there is a risk of precision degradation caused by the position change of the probe tip sensitive to the surroundings. We suggest a 4-port vertical calibration kit to make up for the aforementioned shortcomings. The calibration kit was manufactured for the SOLT calibration method. 'Short', 'Open', and 'Load' are available in the horizontal plane, 'Thru' is available not only in the horizontal plane on the two planes of a PCB, but in the vertical plane between the two planes according to the positions of the probes. We complemented the conventional calibration kit to make a vertical calibration kit to be used for the vertical measurement method. We compared and analysed their reflection/transfer characteristics of the SOLT calibration standards of the proposed calibration kit and conventional one, we get a ${\pm}0.1$ dB differences of transfer characteristics in the range from 300 kHz to 8.5 GHz. In order to demonstrate usefulness, and we performed a case study for horizontal and vertical cases, and compared the results of the proposed calibration kit and conventional one.

Study of N-Port Electric Vehicle Charging Systems Using OPC-UA (OPC UA를 이용한 N-Port EV 충전 시스템 연구)

  • Lee, Seong Joon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.8
    • /
    • pp.343-352
    • /
    • 2017
  • IEC62541, known as OPC-UA, is a standard communication protocol for Smart Grid (SG) and Smart Factory application platform. It was accepted as an IEC standard (IEC62541) in 2011 by IEC TC57, and is extending range of application as collaborating with other standrads. The government's policies to popularize EVs ("Workplace Charging Challenge"), the number of Electric vehicle which try to be charging in the factory is expected to increase. In this situation, indiscreet and uncontrolled EV charging can lead to some problems, such as excess of the peak demand capacity. Therefore, EVs, which is charging in SFs, must be monitoring and controlling to avoid and reduce peak demand. However, the standards for EVs charging differ from the standards for SFs. In other words, to increase the ease of use for drivers, and reduce risk for enterprise, we have needs of study to develop the protocols or to provide interoperability, for EVs charging in SFs. This paper deals with a EV charging management platform installing in a smart factory. And this platform can be easily integrated as part of SF management software. The main goal of this paper is to implement EV management system based on IEC61851 and IEC62541.

Study on Two-Coil and Four-Coil Wireless Power Transfer Systems Using Z-Parameter Approach

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyung Soo
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.568-578
    • /
    • 2016
  • A wireless power transfer (WPT) system is usually classified as being of either a two-coil or four-coil type. It is known that two-coil WPT systems are suitable for short-range transmissions, whereas four-coil WPT systems are suitable for mid-range transmissions. However, this paper reveals that the two aforementioned types of WPT system are alike in terms of their performance and characteristics, differing only when it comes to their matching-network configurations. In this paper, we first find the optimum load and source conditions using Z-parameters. Then, we estimate the maximum power transfer efficiency under the optimum load and source conditions, and we describe how to configure the matching networks pertaining to both types of WPT system for the given optimum load and source conditions. The two types of WPT system show the same performance with respect to the coupling coefficient and load impedance. Further, they also demonstrate an identical performance in the two cases considered in this paper, that is, a strong-coupled case and a weak-coupled case.

Design and Fabrication of Miniature VCO for Cellular Phone (셀룰러 단말기용 소형 VCO 설계 제작)

  • Gwon, Won-Hyeon;Hwang, Seok-Yeon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.9
    • /
    • pp.30-37
    • /
    • 2000
  • In this paper, design and fabrication of miniature voltage-controlled oscillator(VCO) is discussed . Based on the two-port circuit analysis technique, VCO for 900MHz cellular mobile phone is designed and circuit parameters are optimized using the circuit simulator. Using the optimized design parameters, miniature VCO with 6${\times}$6${\times}$1.8 mm$^3$(0.065cc) dimensions is fabricated and experimented. Experimental results show that implemented VCO has -3.5 dBm output power level and 45MHz tunung range, respectively, and has -101.5dB/Hz Phase noise performance at 10 KHz frequency offset.

  • PDF

Suppression of Parallel Plate Modes Using Edge-Located EBG Structure in High-Speed Power Bus

  • Cho, Jonghyun;Kim, Myunghoi
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.4
    • /
    • pp.252-257
    • /
    • 2016
  • An edge-located electromagnetic bandgap (EL-EBG) structure using a defected ground structure (DGS) is proposed to suppress resonant modes induced by edge excitation in a two-dimensional planar parallel plate waveguide (PPW). The proposed EL-DGS-EBG PPW significantly mitigates multiple transverse-magnetic (TM) modes in a wideband frequency range corresponding to an EBG stopband. To verify the wideband suppression, test vehicles of a conventional PPW, a PPW with a mushroom-type EBG structure, and an EL-DGS-EBG PPW are fabricated using a commercial process involving printed circuit boards (PCBs). Measurements of the input impedances show that multiple resonant modes of the previous PPWs are significantly excited through an input port located at a PPW edge. In contrast, resonant modes in the EL-DGS-EBG PPW are substantially suppressed over the frequency range of 0.5 GHz to 2 GHz. In addition, we have experimentally demonstrated that the EL-DGS-EBG PPW reduces the radiated emission from -24 dB to -44 dB as compared to the conventional PPW.

An Experimental Study on Evaluation of Compressive Strength in Cement Mortar Using Averaged Electromagnetic Properties

  • Kwon, Seung-Jun;Maria, Q. Feng;Park, Tae-Won;Na, Ung-Jin
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • A non-destructive testing (NDT) method for evaluating physical properties of concrete including the compressive strength is highly desirable. This paper presents such an NDT method based on measurement of electromagnetic (EM) properties of the material. Experiments are carried out on cement mortar with different water/cement (W/C) ratios. Their EM properties including the conductivity and the dielectric constant are measured at different exposure conditions and curing periods over a wide frequency range of the EM wave. The compressive strength of these specimens is also tested. It is found that both the conductivity and the dielectric constant increase as the W/C ratio decreases and the curing period increases, which lead strength development in the specimens. A linear correlation is observed between the averaged EM properties over the 5 to 20 GHz frequency range and the measured compressive strength, demonstrating the effectiveness of the EM property-based NDT method in evaluating strength of OPC mortar.

A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter (2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계)

  • Kim, Young-Shin;Kim, Seong-Geun;Pu, Young-Gun;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.21-31
    • /
    • 2010
  • This paper presents a design of PLL and SSCG for reducing the EMI effect at the electronic machinery and tools for DisplayPort application. This system is composed of the essential element of PLL and Charge-Pump2 and Reference Clock Divider to implement the SSCG operation. In this paper, 270MHz/162MHz dual-mode PLL that can provide 10-phase and 1.35GHz/810MHz PLL that can reduce the jitter are designed for 2.7Gbps/162Gbps DisplayPort application. The jitter can be reduced drastically by combining 270MHz/162MHz PLL with 2-stage 5 to 1 serializer and 1.35GHz PLL with 2 to 1 serializer. This paper propose the frequency divider topology which can share the divider between modes and guarantee the 50% duty ratio. And, the output current mismatch can be reduced by using the proposed charge-pump topology. It is implemented using 0.13 um CMOS process and die areas of 270MHz/162MHz PLL and 1.35GHz/810MHz PLL are $650um\;{\times}\;500um$ and $600um\;{\times}\;500um$, respectively. The VCO tuning range of 270 MHz/162 MHz PLL is 330 MHz and the phase noise is -114 dBc/Hz at 1 MHz offset. The measured SSCG down spread amplitude is 0.5% and modulation frequency is 31kHz. The total power consumption is 48mW.

A Study of Swirling Flow in a Cylindrical Tube Port 1, Velocity Profiles (수평 원통관내에서 Swirling Flow의 유동에 관한 연구(I))

  • Medwell, J.O.;Chang, T.H.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.4
    • /
    • pp.265-275
    • /
    • 1989
  • An experimental study of decaying swirl air flow has been obtained by tangential inlet in a straight tube with Reynolds number range 20,000~40,000. The friction factor, swirl angle, velocity profiles and turbulent intensity are measured by using micro-manometer and hot-wire anemometer. It is found that the swirl flow behaviors depend on the swirl intensity along the test tube.

  • PDF