• Title/Summary/Keyword: Port Limit

Search Result 201, Processing Time 0.032 seconds

Design of reflection type low phase shift attenuator (반사형 저위상 변화 감쇠기의 설계)

  • 강민수;강원태;장익수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.1-6
    • /
    • 1997
  • A transmission type phase shift attenuator has a poor reflection characteristics at an output port. And that is controlled by the current, its dynamic rnage decreases due to the current limitation. In this paper, to avoid such disadvantages, a reflection type low phase shift attenuator has been designed and measured. As a result, at a center frequency (1855MHz), the sreflection type low pahse shift attenuator has an attenuation of 30dB, within the limit of 3 phase shift and less than -17dB reflection characteristics at both input and output ports. And it demonstrates the peformance of the reflection type low phase shift attenuator is better than the transmission type phase shift attenuator with the same measurement specifications.

  • PDF

A Study on the Mixture Formation and Combustion Characteristics in Lean Burn Engine (희박연소기관의 혼합기형성 및 연소특성에 관한 연구)

  • 이창식;서영호;조행묵;김현정
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.80-86
    • /
    • 1996
  • In order to decrease fuel comsumption rate and emissions, lean burn engine which has equipped swirl control valve, is investigated experimentally on the test bench. Single cylinder engine was used to test the combustion and emission performance with 4 kinds of swirl valve. Decrease in the carbon monoxide, hyerocarbon and specific fuel consumption was shown at the lean condition, which means that a good choice of swirl valve on the given intake port geometry can be used to increase the combustion efficiency and lean limit.

  • PDF

Analysis on Cycle-by-Cycle NO Emissions from an Sl Engine with Fast HO Analyser (고속 NO 분석기를 이용한 Sl 엔진에서의 사이클 변동에 따른 NO 배출에 관한 분석)

  • 성정민;김현우;이경환
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.73-79
    • /
    • 2002
  • The NO emissions at the exhaust manifo1d were investigated with a fast NO analyzer to investigate the cycle-by-cycle variations on NO emissions level and the dependence of NO emissions on combustion. The measurement was performed with a part load condition with respect to the mixture ratios and the changes in loads at 1800rpm. The averaged values were obtained during 200 cycles. We found that there is characteristic pattern in 70 emissions from exhaust port and it was possible to set a representative value with the data sampled during specific period. As the load increased, the characteristics of NO emissions were more dependent on combustion pressures. It was also analyzed that the correlation between combustion pressures and NO emissions for different equivalence ratios tends to increase as the mixture goes leaner, Furthermore, this correlation for the lean mixture near the lean limit seemed to be kept.

A Study on the Oil Pollution Compensation System in Korea (우리나라 유류오염보상제도에 관한 고찰)

  • 서동오
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.4
    • /
    • pp.73-87
    • /
    • 1993
  • As a result of accepting the '71 FUND Convention and enforcing the Oil Pollution Compensation Act 1992, we observed some benefits and costa. This paper analyses those benefits and costs and suggests se-veral key policy recommendations for the estasblishment of an effective oil pollution compensation regime in Korea. This paper identifies the said benefits and costs as follows : First, by establishing the oil pollu-tion compensation system as same as the international level, most of small and medium size of oil pollution damage which are caused by coastal tankers will be compensated by FUND. Second, most of oil pollution damage which are not covered by '69 CLC will be compensated by FUND. Third, some parts of FUND Contribution Fee and CRISTAL Contribution Fee to be charged by major oil companies will be doubled. However the limit of international oil pollution compensation system and the loophole outside the Oil Pol-lution Compensation Act 1992 suggest followings : 1) Radical risk management and insurance manage-ment of ocean going tanker owners, 2) Establishment of oil pollution claim settlement system, 3) Enforce-ment of crew and ship management for coastal tanker and 4) Establishment of Korean P & I Club.

  • PDF

Analysis of Voltage Stability in Electric Railway Feeding System (전기철도 급전계통의 집전전압 안정도 해석)

  • Lee Chang-Mu;Lee Han-Min;Han Moon-Seob;Kim Joo-Rak;Jung Ho-Seong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

A Study on Optimum Pressure Vent of Experimental Booth by Gas Explosion

  • Leem, Sa-Hwan;Lee, Jong-Rark;Huh, Yong-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.59-63
    • /
    • 2007
  • The purpose of this paper is to find optimum vent port of the booth for gas explosion experiment. Also, it is to understand the safety of the booth for explosion experiment which is installed to let the trainees for legal education which is managed by IGTT(Institute of gas technology training) blow the riskiness of explosion. Since the booth for gas explosion experiment is a confined space, we used the exhaust model for indoor explosion. As the result, it was safety calculated when the amount of leaking gas was close to the maximum of explosion limit on the explosion experiment.

  • PDF

A Study on Mooring Limit Analysis of Large Ship (대형 선박의 계류한계에 대한 연구)

  • KIM, Won-Ouk;LEE, Sung-Wook;BAE, Jun-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.415-421
    • /
    • 2017
  • This study is aiming to find one of working conditions for loading and unloading a large ship at game port. Firstly, for dynamic analysis of the moored ships, the motion characteristics of ship according to loading condition are figured out. The motion characteristics of ship is related to environmental factors such as current, wind, mooring line, fender and etc. As a result, it is ascertained through numerical simulation using the AQUA MARINE developed by ANSYS INC. This study might contribute to make a new method of mooring stability of target ship.

Estimation of the Feeding Line Capacity according to Feeding Mehtod (급전방식에 따른 급전선로의 전송용량 예측)

  • Lee, Chang-Mu;Lee, Han-Min;Oh, Se-Chan;Kim, Gil-Dong;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1169-1170
    • /
    • 2007
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway according to the type of feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to feeding method, load, location and power factor of electric locomotive.

  • PDF

Fault Analysis for Electric Railway System (전기철도 시스템의 사고 해석)

  • Lee, Han-Min;Jang, Dong-Uk;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.291-295
    • /
    • 2005
  • This paper presents the modeling of grounding system on Korean electric railway system. The system model is composed of the catenary system, the grounding-system, the sub-sectioning post, the fault point, the sectioning post, the autotransformer in the substation, and the electric vehicle. The increment of rail-ground voltage may be thought as an amplifier of danger on human body of equipment insulation. The rail-ground voltage on steady state and on fault condition should be under standard limit voltage. To analyze grounding system for steady state and fault condition on Korean railway, modeling for each railway system is performed by 10-port network model. Modeling and analysis of present grounding-system are important to protect human and electronic equipments. The examinations for systematic grounding-system are investigated.

  • PDF

A Study on the Fabrication of the 4 Port In-Phase High Power Combiner (4포트 동위상 고출력 전력결합기의 구현에 관한 연구)

  • Lee, Young-Sub;Jeon, Joong-Sung;Lee, Seok-Jeong;Ye, Byeong-Duck;Kim, Dong-Il;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.289-294
    • /
    • 2002
  • The broadband high power 3-way combiner was designed and fabricated for the digital TV repeater. To achieve increase of the bandwidth and the high power capability, Wilkinson type power divider was adopted in our research. First of all, Wilkinson type power divider of equal-split and unequal-split were combined, and the characteristics of the four port in-phase power combiner was simulated for each thickness of dielectric substrates. As the results of simulation, the power combiner fabricated by using dielectric substrate of 120 mil-thickness has the characteristics as follows: insertion loss of less than -651 dB, reflection coefficient of less than -13 dB, isolation among the output ports of less than -15 dB, and pose difference among the output ports of smiler than 13$^{\circ}$. Therefore, this power combiner was possible to improve the limit of microstrip line width due to high impedance, the problem of power loss due to interaction between strip lines in a high power combiner and narrow bandwidth simultaneously. Furthermore, making broadband and high power could be achieved since the fabricated 3-way combiner has good characteristics of insertion loss, the reflection coefficient, separation between ports, and phase difference.