• Title/Summary/Keyword: Porous-media

Search Result 590, Processing Time 0.034 seconds

Fluid Flow in a Multi-Layer Porous Medium (多層多孔質媒體內의 流體流動)

  • 이충구;서정윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.621-626
    • /
    • 1985
  • Unsteady groundwater flow in a three-layer unconfined aquifer has been studied theoretically and experimentally. Two different methods have been used in solving the governing equations of the flow, the nonlinear partial differential equations; (1) The governing equations are linearized for each layer and approximate solutions are obtained. (2) The governing equations are transformed to nonlinear ordinary differential equations, which are solved numerically by Runge-Kutta procedure. Fine, middle sized and coarse sands are used in the experiments. It is found that the solutions from the method(2) ( the reduction of partial differential equations to ordinary differential equations) give better agreement with the experimental results than the solution from the method(1).

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

Fractional order thermoelastic wave assessment in a two-dimension medium with voids

  • Hobiny, Aatef D.;Abbas, Ibrahim A.
    • Geomechanics and Engineering
    • /
    • v.21 no.1
    • /
    • pp.85-93
    • /
    • 2020
  • In this article, the generalized thermoelastic theory with fractional derivative is presented to estimate the variation of temperature, the components of stress, the components of displacement and the changes in volume fraction field in two-dimensional porous media. Easily, the exact solutions in the Laplace domain are obtained. By using Laplace and Fourier transformations with the eigenvalues method, the physical quantities are obtained analytically. The numerical results for all the physical quantities considered are implemented and presented graphically. The results display that the present model with the fractional derivative is reduced to the Lord and Shulman (LS) and the classical dynamical coupled (CT) theories when the fractional parameter is equivalent to one and the delay time is equal to zero and respectively.

Analysis of fluid flow in EK pumps (EK Pumps 내의 유동 해석에 관한 연구)

  • Min, Jung-Yim;Kim, Sung-Jin;Kim, Duck-Jong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1857-1862
    • /
    • 2004
  • EK pumps packed with particles inside capillaries are involved in the mixed electroosmotic flow and pressure driven flow. For analysis in the porous EK pumps, the volume-averaging technique is applied to derive the volume-averaged equations for momentum and electrical potential. By using the volume-averaged equations, analytical solutions for electric potential and velocity distribution due to the mixed electroosmotic and pressure driven flows are obtained. The present analysis is validated by comparison with numerical and experimental results for the case of microchannel EK pumps.

  • PDF

Numerical Study on Convective Heat Transfer within a Vertical Annular Porous Material (다공성 물질의 환형수직원통내에서의 자연대류 열전달 수치해석)

  • Cha, Ki Up;Kim, Chong Bo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.128-137
    • /
    • 1989
  • Numerical solutions for two-dimensional, steady, free convection are presented for a cylinder filled with saturated porous media. An annulus is bounded by inner wall with constant heat flux and two adiabatic horizontal walls with outer wall isothermally cooled. Governing equations are numerically solved for the range of Aspect Ratio 1 to 20, Radius Ratio, 1 to 20, and Rayleigh number, 50 to $10^4$ by Finite Difference method utilizing upwind scheme. Results are presented in terms of stream lines and isotherms, temperature distributions and local Nusselt numbers at the heated wall. Average Nusselt numbers are also presented for the comparisons.

  • PDF

A Study on the Fluid Dynamic of Catalytic Converter in Exhaust Pipe

  • Wangwenhai, Wangwenhai;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.114-118
    • /
    • 2014
  • The need to maximize the exhaust pipe inside surface and to minimize exhaust resistance And Find the best point between the exhaust and the duration of contact between the two surfaces. Exhaust gas mass flow On the whole cross section of catalytic converters more uniform distribution will contribute to its usability. Based on the flow rate of fluid traces given color, Exhaust fluid resistance in the porous catalyst can be estimated, from the efficiency of the catalytic converter that is very important.

Magnetic Properties of Electrodeposited Iron and Cobalt on Porous Aluminum Oxide Layer (다공성 알루미늄 양극산화 피막에 도금된 철 및 코박트의 자기적 성질)

  • Kim, K. H.;Kang, T.;Sohn, H. J.
    • Journal of the Korean institute of surface engineering
    • /
    • v.23 no.3
    • /
    • pp.150-159
    • /
    • 1990
  • The magnetic properties of electrodeposited iron and cobalt films on porous aluminum oxide film were examined. There exists perpendicular magnetic anisotropy due to the shape anisotropy. The coercivity and squareness ratio of films were strongly dependent on deposited particle diameter. The effect of packing fraction on squareness ratio was also apprecible. Unlike the iron-deposited films, the magnetic properties of cobalt films were changed by preferred orientation because of it's large crystal ansotropy constant.(about 10 times of Fe) The Fe deposited films were found to be more suitable for perpendicular magenetic recording media bacause perpendicular coercivity, squareness ratio and the ratio of perpendicular coercivity to horizontal ones of iron films are greater than those of cobalt films.

  • PDF

A Numerical Study on Solute Transport in Heterogeneous Porous Media

  • Jeong, Woo-Chang;Song, Jai-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.05b
    • /
    • pp.1027-1033
    • /
    • 2002
  • The solute transport in a two-dimensional heterogeneous porous medium is numerically studied by using a random walk particle tracking (RWPT) method. Lognormally isotropic hydraulic conductivity fields are generated by using the turning band methods with mean zero and four different values of standard deviation. The numerical transport experiments are carried out to investigate the large time and spatial effects of the variable pore velocity field on solute plumes. The behavior of the solute plume through numerical simulations is presented in terms of longitudinal and transverse spatial moments: displacement of center-of-mass, plume spread variance and skewness coefficient. It was observed that the dispersive behavior of the solute plume is strongly affected by the degree of heterogeneity in the flow domain.

  • PDF

Analysis on the Cooling Characteristics of a Channel with Pin-Fin Structure (핀-휜 구조물을 이용한 채널의 냉각특성 해석)

  • 신지영;손영석;이대영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.667-673
    • /
    • 2003
  • Recent trends in the electronic equipment indicate that the power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. The influence of the structure of the pin-fin assembly on heat transfer is investigated by porous medium model. The results are compared with the experimental data or correlations of several researchers for the heat transfer coefficients for the channel flow with pin-fin arrays. Finally, the effects of design parameters such as the pin-fin diameter and the spacing are examined.

Adhesion and Transport of Bacteria in Iron-coated Media (철코팅 여재에서 박테리아의 부착 및 이동)

  • Lee, Chang-Gu;Park, Seong-Jik;Choi, Nag-Choul;Kim, Song-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.833-838
    • /
    • 2007
  • In this study, adhesion and transport of bacteria in positively-charged media was investigated with batch and column experiments. Bacterial species used in this study was Escherichia coli ATCC 11105(length: 2.2 ${\mu}m$, diameter: 0.6 ${\mu}m$) and media used were quartz sand(particle size distribution: 0.5-2.0 mm, mean diameter: 1.0 mm) and iron-coated sand. Batch results indicate that bacterial adhesion increased as the content of iron-coated media increased. At iron-coated media 0%(quartz sand 100%), around 46% of bacteria was adhered to media while at iron-coated media 100%(quartz sand 0%) about 97% was attached. Column results also show that bacterial adhesion was enhanced with an increase of iron-coated media content. As the iron-coated media content increased from 0 to 100%, bacterial adhesion increased from 8 to 94%. The experimental results demonstrate that positively-charged media could influence transport of bacteria in porous media.