• 제목/요약/키워드: Porous media wall

검색결과 21건 처리시간 0.023초

정수지 내 유동 특성과 유공벽을 이용한 소독능 변화에 대한 수치 해석적 연구 (Numerical Analysis for Characteristics of Flow Fields and Disinfection Performances in the Clearwell with a Porous media Wall)

  • 이석원;리광훈;구자용
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.755-761
    • /
    • 2007
  • Disinfection performance in clearwell is generally measured by CT, which is expressed by $C{\times}T$. C is represented by disinfection concentration, and T is represented by $T_{10}$ which means 90% contact time in clearwell. In order to improve Disinfection performance, augmentation of $T_{10}$ is required. Guide wall has been generally used to improve $T_{10}$ because $T_{10}$ changes according to flow field. In this study, porous media is proposed instead of guide wall, and disinfection performance between guide wall and porous media wall are compared. Flow field and $T_{10}$ in each clearwell are investigated as well. Improved Disinfection performance appear in case of porous media wall compare to guide wall, and best performance occur in porosity factor ${\beta}$ 1e+4.

함수다공질층의 진공건조에 관한 실험적 연구 (Ⅰ) (An Experimental Study on Vacuum Drying of Water-Saturated Porous Media)

  • 박형진;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권5호
    • /
    • pp.68-75
    • /
    • 1996
  • The vacuum drying characteristics of water-saturated porous media were studied experimentally. The water-saturated porous media, water-saturated sand layer, was heated by the isothermal bottom wall of the rectangular vessel. The vacuum drying rate and temperature distribution of the sand layer were measured and calculated under a variety of conditions of heated wall temperature, vacuum rate, and thickness of the test material. It was found that the drying rate due to the heat and mass teansfer is greatly influenced by the heated wall temperature, vacuum rate, and thickness of the test material.

  • PDF

장방형내 함수 다공성 물질의 동결거동에 관한 실험적 연구 (An Experimental study on the Freezing Phenomena of Saturated Porous Media in a Rectangular Cavity)

  • 김병철;김종일;김진흥
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.386-394
    • /
    • 1991
  • Freezing of saturated porous media contained in a rectangular cavity has been studied experimentally. Water and different diameter glass beads consitituted the liquid and porous media. Solidification front shape, the effects of bead diameter and initial liquid temperature was investigated. When the hot wall temperature was below $4^{\circ}C$, the freezing rate was higher at the top than at the bottom due to the density inversion, but with increasing the hot wall temperature the freezing rate at the top was effected by the liquid temperature and was lower than at the bottom. With increasing the bead diameter, the difference of freezing rate between top and bottom was increased and depends on thermal conductivity. When the liquid temperature was low in the beginning, the freezing rate was high, but with increasing the time almost the same with those of high temperature liquid.

  • PDF

단형 수직환형 다공성 물질에 있어서의 자연 대류에 대한 수치해석 (Numerical Study of Natural Convection in Porous Media Bounded by Short Vertical Annulus)

  • 윤종혁;김종보
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.979-990
    • /
    • 1989
  • 본 연구에서는 종횡비가 1보다 크고 내부 벽면에 일정한 열유속을 가지고 외부벽은 등온으로 유지되며 나머지 벽은 단열된 수직환형 원통형에 대한 연구를 바탕으로 같은 경계조건으로 종횡비를 1이하로 감소할 때에 Darcy의 법칙을 기초로 유한차분법을 사용, 수치적으로 해석하여 다세포 유동의 존재 여부와 온도 분포 및 열전달율을 계산하였다.

다공성 재생기의 방향성을 고려한 왕복유동 수치해석 (Numerical analysis in oscillating flow considering orientation of porous media regenerator)

  • 양문흠;박상진;노승탁
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1668-1678
    • /
    • 1997
  • Numerical analyses were performed to investigate the characteristics of regenerator in oscillating flow by using moving boundary method and Darcy model. In this work, periodic adiabatic boundary condition was suggested as the boundary condition of adiabatic part so that the effects of the thermal inertia of the wall could be considered. In carrying out numerical analyses, two models were applied and compared. One called isotropic model has the same thermal conductivity in radial and axial directions within a porous media. The other called aeolotropic model has different conductivity in each directions. Isotropic model could not show the advantage of energy reduction which needs to maintain constant wall temperature difference between heater and cooler. But aeolotropic model could simulate the reduction of energy consumption.

연료탱크 슬로싱 소음 저감을 위한 배플 및 다공성 물질 설치에 따른 유동해석 연구 (A NUMERICAL STUDY ON FLOWS IN A FUEL TANK WITH BAFFLES AND POROUS MEDIA TO REDUCE SLOSHING NOISE)

  • 이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.68-76
    • /
    • 2009
  • The sloshing tank causes the instability of the fluid flows and the fluctuation of the impact pressure by the liquid on the tank. These flow characteristics inside the sloshing tank can generate the uncomfortable sloshing noise. In the present study, a numerical analysis for the reduction of a fuel tank sloshing noise was performed. To simulate the flow characteristics in a sloshing tank with partially filled liquid, a VOF method was used for interfacial flows by applying a momentum source term for the sloshing motion in a non-inertial reference frame. This numerical method was verified by comparing its results with the available experimental data. For the reduction of the sloshing noise, the horizontal and vertical baffles and porous media inside a sloshing tank were considered and numerically analyzed in the present study. For various installations of these baffles and porous media, the characteristics of the liquid behavior in the sloshing tank were obtained along with the impact pressure on the wall and the height of the free surface along the wall. These basic results can be used for the design of the actual vehicular fuel tank with the reduced sloshing noise.

다공성 물질의 환형수직원통내에서의 자연대류 열전달 수치해석 (Numerical Study on Convective Heat Transfer within a Vertical Annular Porous Material)

  • 차기업;김종보
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.128-137
    • /
    • 1989
  • Numerical solutions for two-dimensional, steady, free convection are presented for a cylinder filled with saturated porous media. An annulus is bounded by inner wall with constant heat flux and two adiabatic horizontal walls with outer wall isothermally cooled. Governing equations are numerically solved for the range of Aspect Ratio 1 to 20, Radius Ratio, 1 to 20, and Rayleigh number, 50 to $10^4$ by Finite Difference method utilizing upwind scheme. Results are presented in terms of stream lines and isotherms, temperature distributions and local Nusselt numbers at the heated wall. Average Nusselt numbers are also presented for the comparisons.

  • PDF

Transient filling simulations in unidirectional fibrous porous media

  • Liu, Hai Long;Hwang, Wook-Ryol
    • Korea-Australia Rheology Journal
    • /
    • 제21권1호
    • /
    • pp.71-79
    • /
    • 2009
  • The incomplete saturation and the void formation during the resin infiltration into fibrous porous media in the resin transfer molding process cause failure in the final product during its service. In order to better understand flow behavior during the filling process, a finite-element scheme for transient flow simulation across the micro-structured fibrous media is developed in the present work. A volume-of- fluid (VOF) method has been incorporated in the Eulerian frame to capture the evolution of flow front and the vertical periodic boundary condition has been combined to avoid unwanted wall effect. In the microscale simulation, we investigated the transient filling process in various fiber structures and discussed the mechanism leading to the flow fingering in the case of random fiber distribution. Effects of the filling pressure, the shear-thinning behavior of fluid and the volume fraction on the flow front have been investigated for both intra-tow and the inter-tow flows in dual-scale fiber tow models.

Study on the Natural Convection Heat Transfer Characteristics in the Air Duct

  • Kim, Y.K.;Lee, Y.B.;Park, S.K.;J.S. Hwang;H.Y. Nam
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.451-456
    • /
    • 1997
  • Temperature distribution measurements in the mockup apparatus of reactor vessel were performed to determine the effective thermal conductivity of porous media with different geometry and to obtain the experimental data for the heat transfer processes by natural convection occurring in the air duct. The temperature distributions at four separated sections with different arrangements of porous media have different slopes according to the geometrical configuration. From the measured temperature distribution, effective thermal conductivity have been derived using the least square fitting method. The test at air duct was performed to the high heat removal at 3.4kW/$m^2$ by the natural convection from the outer wall to the air. And also the temperature distributions in the air duct agree well with the 1/7th power-law turbulent temperature distribution. The obtained heat transfer data have been compared with the Shin's and Sieger's correlations.

  • PDF

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권2호
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.