• 제목/요약/키워드: Porous Flow Analysis

검색결과 235건 처리시간 0.031초

Impact of Air Convection on H3PO4-Activated Biomass for Sequestration of Cu (II) and Cd (II) Ions

  • Girgis, Badie S.;Elkady, Ahmed A.;Attia, Amina A.;Fathy, Nady A.;Abdel Wahhab, M. A.
    • Carbon letters
    • /
    • 제10권2호
    • /
    • pp.114-122
    • /
    • 2009
  • Crushed, depitted peach stones were impregnated activated with 50% $H_3PO_4$ followed by pyrolysis at $500^{\circ}C$. Two activated carbons were produced, one under its own evolved gases during pyrolysis, and the second conducted with air flow throughout the carbonization stage. Physicochemical properties were investigated by several procedures; carbon yield, ash content, elemental chemical analysis, TG/DTG and FTIR spectra. Porosity characteristics were determined by the conventional $N_2$ adsorption at 77 K, and data analyzed to get the major texture parameters of surface area and pore volume. Highly developed activated carbons were obtained, essentially microporous, with slight effect of air on the porous structure. Oxygen was observed to be markedly incorporated in the carbon matrix during the air treatment process. Cation exchange capacity towards Cu (II) and Cd (II) was tested in batch single ion experimental mode, which proved to be slow and a function of carbon dose, time and initial ion concentration. Copper was up taken more favorably than cadmium, under same conditions, and adsorption of both cations was remarkably enhanced as a consequence of the air treatment procedure. Sequestration of the metal ions was explained on basis of the combined effect of the oxygen functional groups and the phosphorous-containing compounds; both contributing to the total surface acidity character.

비활성 화산지역의 지중공기열원 에너지 이용에 관한 실험적 연구 (An Experimental Study on the Availability of Underground Air Energy Source in Non-Activity Volcanic Island)

  • 김용환;박성식;김우중;김남진;현명택
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.73-80
    • /
    • 2014
  • This study introduces and analyzes the geothermal energy availability in Non-active volcanic region. Jeju island in Korea is situated in non-active volcanic region. The island is composed of rock with high pore and clinker, scoria geological layer formed by volcanic activity about two million ago. Volcanic geological layers with porous characteristics have air, vapor, water and a underground structure through which air or water can move easily. For this reason, it is probable that the mechanism of energy acquisition is by convective heat transfer. For this presumption, the availability of underground air as energy source has been studied here through theoretical analysis and experimental data. The energy output of our system ranged from 2,485,076 kJ/day to 4,060,978 kJ/day monitored using variable velocity air flow controller. Our system has capability to be a reliable energy source irrespective of environmental changes. Consequently, underground air can be utilized for energy source and provide the optimal design of heating/cooling system.

Numerical and statistical analysis of Newtonian/non-Newtonian traits of MoS2-C2H6O2 nanofluids with variable fluid properties

  • Manoj C Kumar;Jasmine A Benazir
    • Advances in nano research
    • /
    • 제16권4호
    • /
    • pp.341-352
    • /
    • 2024
  • This study investigates the heat and mass transfer characteristics of a MoS2 nanoparticle suspension in ethylene glycol over a porous stretching sheet. MoS2 nanoparticles are known for their exceptional thermal and chemical stability which makes it convenient for enhancing the energy and mass transport properties of base fluids. Ethylene glycol, a common coolant in various industrial applications is utilized as the suspending medium due to its superior heat transfer properties. The effects of variable thermal conductivity, variable mass diffusivity, thermal radiation and thermophoresis which are crucial parameters in affecting the transport phenomena of nanofluids are taken into consideration. The governing partial differential equations representing the conservation of momentum, energy, and concentration are reduced to a set of nonlinear ordinary differential equations using appropriate similarity transformations. R software and MATLAB-bvp5c are used to compute the solutions. The impact of key parameters, including the nanoparticle volume fraction, magnetic field, Prandtl number, and thermophoresis parameter on the flow, heat and mass transfer rates is systematically examined. The study reveals that the presence of MoS2 nanoparticles curbs the friction between the fluid and the solid boundary. Moreover, the variable thermal conductivity controls the rate of heat transfer and variable mass diffusivity regulates the rate of mass transfer. The numerical and statistical results computed are mutually justified via tables. The results obtained from this investigation provide valuable insights into the design and optimization of systems involving nanofluid-based heat and mass transfer processes, such as solar collectors, chemical reactors, and heat exchangers. Furthermore, the findings contribute to a deeper understanding of stretching sheet systems, such as in manufacturing processes involving continuous casting or polymer film production. The incorporation of MoS2-C2H6O2 nanofluids can potentially optimize temperature distribution and fluid dynamics.

마이크로 원통형 SOFC 제작 및 특성평가 (Fabrication and Evaluation Properties of Micro-Tubular Solid Oxide Fuel Cells (SOFCs))

  • 김환;김완제;이종원;이승복;임탁형;박석주;송락현;신동열
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.749-753
    • /
    • 2012
  • 본 연구에서는 마이크로 원통형 SOFC 지지체의 특성을 평가하기 위해 직경 3 mm의 연료극 지지체를 제조하여 지지체의 미세구조를 분석하고, 기계적 강도 및 가스투과도를 측정하였다. 다공성 연료극 지지체의 표면과 파단면의 미세구조를 분석하기 위해 SEM (Scanning Electron Microscope)을 이용하였다. 지지체의 가스투과도는 차압계를 이용하여 50, 100, 150 cc/min의 유량에서 측정하였으며, 기계적 강도는 만능 시험기를 이용하여 측정하였다. 마이크로 원통형 연료극 지지체의 기본적인 물성 평가 후 NiO-YSZ, YSZ, YSZ-LSM/LSM/LSCF로 구성된 마이크로 SOFC 단위전지를 제조하였으며, 반응온도와 연료 유량별로 성능평가를 수행하여 $800^{\circ}C$에서 $1095mW/cm^2$의 출력이 얻어짐을 확인하였다. 또한, 반응 온도에 따른 전기화학적 임피던스 특성평가를 통하여 온도가 높아질수록 전해질 이온전도도가 증가되어 ohmic 저항이 감소되고 그에 따라 마이크로 관형 SOFC 셀 성능이 증가함을 확인할 수 있었다.

UPS 파워 팩 내부 연료전지의 냉각특성에 대한 수치 해석 (A Study on Numerical Analysis for Internal PEMFC Cooling of Power Pack for UPS)

  • 송준석;김병헌
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.527-535
    • /
    • 2017
  • 연료전지 배터리 하이브리드 UPS용 연료전지 파워 팩 내부에 설치한 연료전지의 화학반응에 의해 생성되는 열을 제거하는데 어려움이 있다. 열을 제거하지 못할 경우 연료전지의 내구성과 성능에 영향을 끼쳐 수명 단축의 원인이 된다. UPS용 연료전지 파워 팩 제작을 위하여 연료전지의 적절한 냉각 방법을 선정하고 제시하는 것이 본 연구의 목표이다. 냉각방법 선정을 위해 냉각 성능에 영향을 주는 각각의 설계 인자를 변화시키면서 연구를 수행하였다. 전산해석은 상용프로그램인 COMSOL Multiphysics로 수행하였다. 먼저 연료전지 스택의 냉각 팬의 위치를 상단과 하단에 배치했을 때 1 kW급 연료전지 스택 표면온도를 비교하였으며, 각각의 위치에 따른 냉각 팬의 회전속도를 2,500, 3,000, 3,500, 4,000 RPM으로 변경하여 적절한 냉각 팬의 속도를 결정하였다. 또한 파워 팩 외부에서 내부로 들어오는 공기의 입구인 그릴의 타공면적을 달리하여 내부로 들어오는 공기의 유량이 냉각에 미치는 영향을 비교하였다. 본 연구는 UPS용 연료전지 파워 팩 내부 연료전지의 열관리 기술개발에 효과적으로 활용될 수 있을 것으로 판단된다.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구 (Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District)

  • 신현석;김미은;김재문;장종경
    • 한국수자원학회논문집
    • /
    • 제46권12호
    • /
    • pp.1193-1207
    • /
    • 2013
  • 지나친 도시개발은 불투수면적의 증가로 인한 유출 증가를 야기하며 이는 홍수 및 비점오염에 대한 문제 및 기저유출감소로 인한 지하수위 감소에 따라 하천을 건천화시키는 문제를 발생시킨다. 이러한 문제를 해결하기 위한 방안으로 저영향개발(LID, Low Impact Development) 기법이 제시되고 있다. 즉, LID 기법을 적용함으로써 개발 이전의 수문순환 상태를 모사하여 개발로 인한 영향을 최소화하고 물 순환구조를 개선하고자하는 연구가 진행되고 있다. 국내에서도 LID 개념의 도입이 지속적으로 증가함에 따라 소규모 배수 분구를 중심으로 연구가 진행되고 있다. 또한, 중규모 이상의 유역에 LID 기법을 적용 시 유역 내 수문학적 유출 특성과 오염 발생 특성 변화에 대한 분석 방안이 요구되지만 하수처리분구 단위의 수문학적 영향을 분석 할 수 있는 연구는 미흡한 실정이다. 본 연구에서는 하수처리 구역 내 LID 기법의 적용에 따른 물순환 개선효과와 비점오염 저감효과 분석 및 기존 관리기법과의 비교를 통해 유역관리 측면에서의 적정 LID 설치면적 추정 방안을 검토하였다. LID 적용효과 분석을 위하여 소규모 배수 분구인 부산시 동래천 유역과 하수처리구역인 온천천 유역을 대상유역으로 선정하였으며 동래천 유역을 대상으로 LID 요소기술의 적용가능 면적을 추출하고 비율로 환산한 후 온천천 유역으로 확대 적용하였다. LID 요소기술 중 우리나라의 토지이용 밀집도를 고려하여 적용이 용이한 Green Roof와 Porous Pavement 및 도로에 설치되는 Street Planter를 선정하였으며 유역별로 구축된 LID 기법 기반의 SWMM 모형을 이용하여 토양특성과 강우특성을 고려한 물순환 기능 개선효과 및 비점오염량 저감효과를 분석하였다. 또한 온천천 유역을 대상으로 기존 비점오염 관리방안인 오염원 및 방류량에 따른 처리효율과 LID 적용 시의 처리효율을 비교하였으며 비교자료를 토대로 유역관리와 비용적인 측면을 고려한 적정 LID 설치비율로서 기존 비점오염 관리방안의 처리효율을 만족하는 LID 설치비율을 선정하고 이에 대한 적용 가능성을 검토하였다.

분황사석탑 구성 화강암의 훼손현상 (Deterioration of granite in Bunhwangsaseoktap (Stone pagoda of Bunhwnagsa Temple))

  • 도진명
    • 보존과학회지
    • /
    • 제17권
    • /
    • pp.73-82
    • /
    • 2005
  • 분황사석탑은 가장 오래된 신라시대의 모전석탑이다. 탑신부는 벽돌처럼 제작된 검은 안산암으로 이루어져 있으며, 화강암으로 조성된 감실이 1층탑신석에 있다. 1915년 대대적인 수리가 행해졌으나, 현재 석탑의 구성암석에서는 여러 손상의 형태들이 나타나고 있다. 특히 구성화강암 표면에서는 박리 사질상입자분해 등이 심하게 나타나고 있다. 본 연구에서는 다양한 분석을 통하여 구성화강암의 정확한 훼손현황을 살펴보았고, 탑신부에 나타나고 있는 백화현상과의 관계를 통해 그 손상원인을 찾아보았다. 연구결과, 구성 화강암은 석탑 표면에 발생된 백화현상의 원인 물질로 인해 훼손이 가중되고 있는 것으로 알려졌다. 백화현상의 원인 물질은 질산나트륨. 황산칼슘, 황산나트륨 등의 수용성 염류로, 백색 줄눈몰타르에서 기인한 것이다. 석탑의 외부는 이러한 백색 줄눈몰타르가 수분과 반응하여 재결정화되고 있지만, 많은 부분이 빗물에 의해 씻겨 내려가다가 밖으로 배수되는 것으로 생각된다. 이 과정에서 빗물에 용해된 염성분들이 감실을 구성하고 있는 화강암을 거쳐가게 되고, 다공성의 화강암은 모세관현상에 의해 이 염들을 수분과 함께 암석의 내부로 흡수한다. 그러므로 구성화강암이 갖고 있는 염문제를 줄일 수 있는 방법은 백색 줄눈몰타르를 용해성이 적은 다른 물질로 대체하는 것이다. 또한 석탑내부로 흘러들어온 수분이 백색 줄눈몰타르를 용해시킬 수 있기 때문에, 상부에서 석탑내부로 수분이 흘러내리지 않도록 조치를 취하는 것이 필요하다.

  • PDF

터널 굴착으로 인한 터널인접 절리암반 투수계수 감소를 고려한 터널 내 지하수 유입량 산정방법 (Groundwater inflow rate estimation considering excavation-induced permeability reduction in the vicinity of a tunnel)

  • 문준식
    • 한국터널지하공간학회 논문집
    • /
    • 제15권3호
    • /
    • pp.333-344
    • /
    • 2013
  • 본 연구에서는 절리 암반 내 터널굴착 시 지하수 유출량 예측량이 실제 계측치와 큰 차이가 나는 이유 중 하나인 터널주변 절리암반의 투수계수의 감소 현상에 대해 논의하였다. 현재 터널 설계 시 일반적으로 사용되고 있는 지하수 유출량 산정식은 터널주변 암반이 등방, 균질하고 일정한 투수계수를 유지한다고 가정한다. 하지만, 실제로는 터널주변 절리암반의 투수계수는 터널주변 유효응력 상태에 따라 변화하며, 절리 내 지하수 흐름에 따라 다시 터널주변 유효응력 분포가 영향을 받는 수리-역학적 상호거동을 보인다. 터널굴착 직후 터널 접선방향 유효응력이 응력집중과 간극수압 감소로 인해 급증하고 그에 따라 절리의 닫힘현상이 발생하며, 결과적으로 터널인접 절리암반 링 구간에서 투수계수가 급격히 감소하게 된다. 이러한 터널인접 링 구간 내에서 상당히 큰 간극수압 감소가 발생하게 되어 터널주변 간극수압 분포는 등방 균질의 절리암반으로 가정한 산정식과 큰 차이를 보인다. 본 연구에서는 절리암반의 수리-역학적 상호거동의 개념을 도입하여 터널주변 간극수압 분포와 터널 내 지하수 유입량 산정방법을 제안하고 이를 수치해석을 통해 검증하였다.

Li2ZrO3를 이용한 합성가스내의 CO2 제거 (Removal of CO2 in Syngas using Li2ZrO3)

  • 박주원;강동환;유경선;이재구;김재호;한춘
    • 공업화학
    • /
    • 제17권3호
    • /
    • pp.250-254
    • /
    • 2006
  • $Li_{2}ZrO_{3}$$CO_{2}$ 제거능을 평가하기 위하여 열중량분석기(thermogravimetric analyser, TGA)를 사용하여 실험하였고 $Li_{2}ZrO_{3}$를 이용한 $CO_{2}$ 제거반응시 $H_{2}$와 CO의 영향을 평가하기 위하여 충전층 반응기를 이용하여 실험하였다. $Li_{2}ZrO_{3}$$CO_{2}$ 제거반응 초기속도는 가스유량 증가에 따라 일정하게 증가하였고 가스유량 100 mL/min 이상에서 기체경막저항 소멸에 따라 일정하게 유지되었다. $Li_{2}ZrO_{3}$$CO_{2}$의 반응차수는 1차임을 확인했으며 최적온도 구간은 $500{\sim}600^{\circ}C$로 나타났으며, XRD와 SEM을 이용하여 $Li_{2}ZrO_{3}$의 구조를 살펴본 결과 결정구조의 $Li_{2}ZrO_{3}$와 다공성의 $Li_{2}CO_{3}$/$ZrO_{2}$로 구성되어 있음을 확인하였다. 또한 $CO_{2}$ 내의 $H_{2}$ 존재는 $CO_{2}$ 제거반응에 영향을 미치지 않지만 CO의 경우 $Li_{2}ZrO_{3}$상의 $Li_{2}CO_{3}$(L)에 흡착되는 $CO_{2}$의 수착을 억제하는 것으로 나타났다.