• Title/Summary/Keyword: Porcelain polishing

Search Result 30, Processing Time 0.022 seconds

Adhesion Properties of Epoxy Resin Adhesive Reinforced Tile (에폭시 수지 접착제를 보강한 타일의 부착성능 평가)

  • Lee, Sang-Kyu;Kim, Gyu-Yong;Hwang, Eui-Chul;Son, Min-Jae;Lee, Sang-yun;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.128-129
    • /
    • 2020
  • In this study, flexural strength and tile adhesion strength were evaluated by using a mortar, dry mortar and an epoxy resin reinforced mortar to examine the adhesion performance by reinforcing the epoxy resin adhesive. As a result, it was clearly confirmed that the effect of improving the adhesion strength by reinforcing the epoxy resin adhesive regardless of the type of tile, and in particular, when applying the epoxy resin adhesive to the porcelain and polishing tiles, it is judged that sufficient adhesion performance can be secured.

  • PDF

Safety education needs among the dental technology-major college students to prevent injuries in their laboratory classes (치기공과 학생들의 실습 중 안전에 대한 안전교육 요구도 특성)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.177-198
    • /
    • 2006
  • This study purposed to offer basic data for safety education of the dental laboratory technology after the investigation of how much the students in the dept. of dental laboratory technology are aware of the danger of each instrument, equipment or laboratory procedure that they use during laboratory and how much they demand safety education for this. The objects for this study were 423 students who were in the dept. of dental laboratory technology. In this regard, four colleges which have the dept. of dental laboratory technology were randomly selected to do a questionnaire survey. SPSS 12.0 was used to analyze the collected data. The results were as follows: As for satisfaction with their major, the respondents answered Satisfied (59.1%), Average (35.5%) and Dissatisfied (5.4%). In terms of the production process of a partial denture, they considered casting, polishing the casting body, polishing denture and burn out were most dangerous in order. As for the production process of a full denture, what they regarded as the most dangerous in order was polishing denture, deflasking and wax wash. Regarding the laboratory procedures of porcelain material, casting, trimming casting body, polishing porcelain material and burn out were the most dangerous procedures that they perceived. With regard to materials for use, alcohol, polishing, metal and wire were the most dangerous ones they thought. As for the handling characteristics of each material, small towns showed a higher demand for safety of the handling characteristics of alcohol. In terms of school year and sex, juniors and girls had higher scores in the demand for safety of the handling characteristics of acid. Regarding the handling characteristics of each equipment and instrument, all of small towns, juniors and girls showed the highest demand for safety of the handling characteristics of alcohol lamps. With regard to scores in the demand for safety of other characteristics, all of small towns, juniors and girls had the highest demand for safety of emergency treatment. Concerning the demand for safety education by the completion of safety education, in terms of each material, highest was the demand for safety of acid from the group which completed safety education. In regard to equipments and instruments, when it came to the demand for safety of the handling characteristics of casting machine, the educated group's demand for safety of acid was higher. Regarding other characteristics, the group which was not educated gained higher scores in the demand for safety of emergency treatment. 11. In all areas(materials, machines and others), small towns, girls and juniors showed higher scores in the demand for safety. Based on the above results, it was found that when students conduct the laboratory of dental technology, they would think that many materials, instruments or equipments for use are very dangerous. However, safety education was not fully given to them. Regarding the scores in the damned for safety education, the highest was 4.16 and the lowest was 3.43, which suggests that the scores were generally very high. In this regard, it is necessary to continue delivering a systematic safety education of materials, equipments or instruments used during the laboratory of dental technology. Therefore, through the analysis of each material, instruments or facility used in every laboratory and each process, safety accident types and accident risk factors should be investigated to develop educational materials for this. Moreover, it is required to open safety education as a single course of study or insert safety contents of all materials and machines into the class of dental laboratory instrument or dental materials for the purpose of a systematic and thorough safety education to prevent a safety accident during laboratory.

  • PDF

COMPARATIVE EVALUATION OF LIGHT-CURED COMPOSITE RESINS BASED ON VITA SHADE BY SPECTROCOLORIMETER (분광색채계측기를 이용한 Vita Shade 광중합형 복합레진의 색상 비교)

  • Cho, Kyoung-Yee;Hwang, In-Nam;Choi, Hong-Ran;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.424-432
    • /
    • 1998
  • To get a satisfactory result in the composite resin restorations, it is necessary to choose correct shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guide or Bioform shade guide, but color differences might be expected even using the same shade in various materials. In this study, five kinds of light-cured composite resins with A2 and B3 shade were used to measure and compare the color each other while one porcelain served as a control. All composite resins (Spectrum TPH (SP), VeridonFil- Photo (VE), Z100 (Z100), Charisma (CH), Prodigy (PRO)) were filled in to the metal mold (12 mm diameter, 2 mm depth), followed by compression, polymerization and polishing with wet sandpaper. The specimens of porcelain were fabricated by using the refractory mold for porcelain. After 24 hours, the specimens were placed on the spectrocolorimeter and spectral reflectance were measured under CIE illuminant D65. After measuring the values of $L^*$, $a^*$, $b^*$ and ${\Delta}E^*$, following results were obtained; 1. The $L^*$, $a^*$ and $b^*$ values of both shade of porcelain specimens showed significantly higher than those of resin specimens(p<0.05). 2. In comparing the resin specimens of the A2 shade, differences were significant except $L^*$ values of SP-CH and PRO-VE, $a^*$ values of the VE-SP and $b^*$ values of the VE-Z100 and SP-PRO(p<0.05), 3. In comparing the resin specimens of the B3 shade, differences were significant except $L^*$ values of PRO-SP, $a^*$ values of the SP-PRO and Z100-VE and b* values of the PRO-SP(p<0.05). 4. In comparing the resin specimens of the A2 shade, color differences between materials (${\Delta}E^*$) showed the lowest value of 1.66, and the highest was 5.16. ${\Delta}E^*$ values of the materials of VE-PRO, CH-PRO, SP-PRO, SP-Z100 and SP-CH were lower than 3.3. 5. In comparing the resin specimens of the B3 shade, the lowest value of the ${\Delta}E^*$ was 0.57 and the highest was 5.92. ${\Delta}E^*$ values of Z100-CH and SP-PRO were lower than 3.3. The present study revealed there was perceptible color difference between materials even if they have the same designated shade based on Vita shade guide. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

  • PDF

A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

A Study on the Noise by working Process in Dental Laboratory (치과기공실(齒科技工室)의 작업공정별(作業工程別) 소음(騷音)에 관한 연구(硏究))

  • Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.15 no.1
    • /
    • pp.27-41
    • /
    • 1993
  • Degree of noise by personal dental laboratory working process and degree of noise by complex dental laboratory working process were measured separtely. The time of exposure to noise greater than 70dB was analyzed. Then, the whole degree of noise in dental laboratory was estimated on the basis of afore-mentioned information. Questionaire were employed to investigate the mental, emotional and physiological effects of noise in dental technicians, The purpose of this study was to provide basic information on keeping dental techneicans who are exposed to noise pollution in good working condition and good health. Results obtained are as follows ; 1. Polishing process in each working part showed high degree of noise greater than 70dB in terms of degree of noise by personal working. 2. Degree of noise by complex working process in each working part was greater than that of personal working process. 3. Time of exposure to noise complex working process the part of porcelain 150min, partial denture 120 min, crown and bridge 100 min, full denture 80 min. 4. Degree of noise by time in dental laboratory was 80dB in general for polishing process and below 75dB for waxing process. 5. Effects of noise on mental and emotional state of dental technicians showed that they felt irritated every day(14%), irritated once in a while(29%) and easily ger mad(19%). 6. Effects of noise on heart and stomach were hyper-gastric acid(38%), gastric ulcer(11%), gastritis(5%), deuodenal ulcer(3%) and weak heart function(32%). 7. Effects of noise in the hearing ability were weak(39%), moderate(33%) and normal(14%) Data presented in this study demonstrated that noise in the dental laboratory exerts profound effect on dental technicians mentally, physiologically and emotionally, in light of the above results, therefore, it appears advisable to devots substantial on the management of working condition and put further(continuing) efforts in the investigation for reducing noise problem.

  • PDF

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Influence of coloring liquids on the shear bond strength between zirconia and veneering ceramic (색소체용액 침투가 지르코니아 및 전장용 세라믹의 전단결합강도에 미치는 영향)

  • Jung, Jong-Hyun;Oh, Gye-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.291-298
    • /
    • 2016
  • Purpose: This study was to evaluate the effect of coloring liquids on the shear bond strength between zirconia and veneering ceramic. Methods: Zirconia(15 mm in diameter, 2.5 mm in thickness; n=40) used in the experiment were divided into 5 groups depending on the coloring liquid. Each specimen were polished using a polishing machine(LaboPol-2, Struers, UK). A cylinder of veneering porcelain(6 mm in diameter, 3 mm in thickness) was fabricated and fired on zirconia surfaces. The shear bond strength was measured using a universal testing machine(Model 4302, Instron, USA). All data were analyzed statistically using a one-way ANOVA and Tukey's multiple comparisons test. After the shear bond test, fracture surfaces were examined by SEM. Results: Colored zirconia showed a higher shear bonding strength than that of uncolored zirconia except for colored zirconia immersed in Zirkonzahn coloring liquid. In particular, colored zirconia immersed in Kuwotech coloring liquid showed the highest shear bond strength. After the shear bond test, mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. Conclusion: Coloring liquid enhanced the shear bond strength zirconia and veneering ceramic than uncolored zirconia.

Accidents research Ⅰ for the college students in their Dental Laboratory Technology-major classes (치기공과 실습 중 안전사고 실태 조사 Ⅰ)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.115-129
    • /
    • 2005
  • The purpose of this study was to identify injury characteristics happened in the college dental laboratory technique classes and to provide the empirical accident findings for safety education development for the college dental technology classes. The research data were collected from a self-administered survey distributed to the conveniently selected college students. The study participants were 476 freshmen, sophomore and junior students whose major was the dental laboratory technology of the 4 colleges in 2 metropolitan cities and 2 medium-size cities. All collected survey responses were encoded and analyzed in SPSS 12.0. The findings were as follows. The accidents happened to the college students during the dental laboratory technology classes: 1. The accident rate was the highest in the sophomore and the freshmen, junior in order. 2. The body parts frequently injured were hands, face, eyes, arms, and legs in order. 3. The frequent injury types were cut, burnt, stuck, wound, and suffocated in order. 4. The treatment methods for their accidents were the simple first-aids, no treatment, and the emergency room visits in order. 5. The laboratory training conditions inducing the accidents were significantly frequent under wire-related, and wax-related, iron-related, alcohol-related jobs in order, but not frequent in investing material-related, porcelain-related, resin-related, and agar-related jobs. Polishing was the most accident-prone job explaining 63% of the laboratory accidents and then, model producing, wax patterning, casting, burning, and investing jobs in order. In summary, the college dental laboratory accidents had the certain patterns by the training level and by the material or machine involved in each class. Thus, the planned and organized safety education programs should be produced and investigated for college students before their major laboratory classes.

  • PDF

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

A study on enamel thickness of maxillary incisors using X-ray micro computed tomography (MicroCT를 이용한 상악 전치의 법랑질 두께에 관한 연구)

  • Cho, Young-Won;Cho, Jin-Hyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.301-307
    • /
    • 2010
  • Purpose: The objectives of the current study are to assess the accuracy of X-Ray Micro Computed Tomography (microCT) in measuring enamel thickness and to evaluate enamel thickness in maxillary incisors of Koreans. Materials and methods: Five maxillary incisors were embedded in resin block. These teeth were longitudinally sectioned labiolingually through the medial axis. After polishing, the teeth were scanned using a microCT (X-EYE SYSTEM; DRGEM, Seoul, Korea). On a scanning electron microscope (S-4300; Hitachi, Tokyo, Japan) (${\times}20$) and a microCT, nearly identical planes were reconstructed. In each tooth, the thickness of labial enamel was measured 1, 3 and 5 mm above the cementoenamel junction (CEJ). Thus, the accuracy of the microCT was evaluated. In addition, using 26 maxillary central incisors and 11 maxillary lateral incisors, in the medial axis and 2 mm remote areas mesially and distally from the medial axis, the thickness of labial enamel was measured 1, 3 and 5 mm above the CEJ along the long axis of the teeth. Results: Measurements from nearly identical planes in physical and microCT sections differed by 3.81%. An independent t-test was performed and this showed that there were no significant differences in the measurements between the two methods. Mean values of labial enamel thickness in maxillary central incisors 1, 3 and 5 mm above the CEJ were $0.32{\pm}0.01$, $0.50{\pm}0.0.2$ and $0.70{\pm}0.02\;mm$, respectively. Mean values of labial enamel thickness in maxillary lateral incisors 1, 3 and 5 mm above the CEJ were $0.30{\pm}0.01$, $0.55{\pm}0.03$ and $0.80{\pm}0.02\;mm$, respectively. Conclusion: In measuring enamel thickness, microCT is one of useful way of measurement. So according to the results of this research, when restoring a porcelain laminate veneer on maxillary incisors in Koreans, careful consideration is needed in the amount of enamel reduction.