• 제목/요약/키워드: Porcelain polishing

검색결과 30건 처리시간 0.021초

글레이징처리한 도재와 연마한 도재의 표면조도에 관한 연구 (A STUDY ON THE SURFACE ROUGHNESS OF GLAZED PORCELAIN AND POLISHED PORCELAIN)

  • 최미라;정헌영;이선형;양재호
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.549-565
    • /
    • 1998
  • Porcelain is considered to be one of the materials of choice for restoration where esthetics is of concern. But porcelain surface without final glazing treatment may induce undesirable results such as inflammatory response on adjacent soft tissues due to plaque accumulation and increased wear of opposing teeth. Therefore, rough porcelain surface must be smoothened by final glazing treatment or chairside polishing procedure. The purpose of this study was to compare the surface roughness among self-glazed, overglazed and polished porcelain with various polishing kit, and to detect which phase of polishing is optimal in clinic. Specimens were fabricated with Vita VMK porcelain. The surface treatment of each group was performed as follows. Group 1 : overglazing treatment Group 2 : self-glazing treatment Group 3 : polishing with the Truluster Polishing System for Porcelain(Brasseler, U.S.A.) Group 4 : polishing with the Exa Cerapol Adjustment kit (Edenta dental products, Switzerland) followed by finishing with diamond-filled polishing paste Group 5 : polishing with the Shofu Porcelain Adjustment kit (Shofu inc., Japan) followed by finishing with diamond-filled polishing paste. At each polishing steps, the measurement of Ra and Rq values were performed, and the surface was examined by scanning electron microscope. The results were as follows : 1. Overglazing treatment brought smoother surface than self-glazing treatment. 2. Polishing systems without porcelain polishing paste did not make better result than self-glazing treatment. 3. Polishing system with porcelain polishing paste made similar result to overglazing treatment. 4. Applying diamond-filled polishing paste after using polishing system which has no porcelain polishing paste produced surface as smooth as overglazing treatment does.

  • PDF

라미네이트 도재 수복물의 연마 방법에 따른 표면 거칠기의 비교 (COMPARISON OF SURFACE ROUGHNESS OF VARIOUS LAMINATE VENEER PORCELAIN ACCORDING TO POLISHING METHODS)

  • 권영숙;이근우
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.246-265
    • /
    • 1996
  • After adjusting glazed surface of laminate veneer porcelain by reduction in the clinical procedure, an additional polishing procedure is required to smoothen the roughened surface by reduction, as it is difficult to glaze it again in the furnace. In this study, four kinds of laminate veneer porcelain were ground with diamond points as done in the clinical procedure. The adjusted porcelain surface was polished with Durawhite stone, Ceramiste points, Exa cerapol, Porcelain polishing wheel, Diamond polishing paste. The degree of surface roughness was evaluated with SEM and profilometer at each step, The self glazed surface and the glazed surface with glazing powder were compared with the polished surface and surface roughness of four kinds of laminate veneer porcelain according to the polishing method and step were obserbed. The following results were obtained : 1. There was no difference in the average surface roughness Ra value and the surface roughness obserbed under SEM according to the polishing methods and steps used, among the four kinds of laminate veneer porcelain including Colorlogic, Exelco, Vintage, and Vitadur alpha product. 2. Due to porosities, the surface in the course of polishing by polishing instruments was rougher than the glazed surface, evaluated with a SEM. 3. Insta-Glaze diamond polishing paste has no statistical difference with self glazed group 1, although it has a lower value in average surface roughness Ra value. 4. Group 2 which was glazed with galzing powder was lowest in view of SEM, but it revealed higher surface roughness Ra value than group 1, the glazed surface and group 8, polished by diamond polishing paste, due to surface waveness. 5. Proper surface smoothness could not be in the surface roughness analysis of SEM and profilometer by Shofu laminate polishing kit composed of Diamond point, Durawhite stone and Ceramiste points. Based on the results of this study, the following conclusions can be drawn. We obtain low surface roughness than glazed surface by polishing instruments, but not perfect results clinically. In order to obtain a perfect clinical result or a surface smoothness comparable to glazed porcelain there is a need for further improvement of porcelain materials, condensa-tion techniques, polishing instruments and polishing methods. Furthermore card should be taken not to breakdown the glazed surface during the clinical and laboratory procedure.

  • PDF

Evaluation of efficiency of manual polishing over autoglazed and overglazed porcelain and its effect on plaque accumulation

  • Haralur, Satheesh B.
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.179-186
    • /
    • 2012
  • PURPOSE. The aim of this study was to evaluate the efficiency of manual polishing over autoglazed and overglazed porcelain and their effect on plaque accumulation. MATERIALS AND METHODS. Thirty-six porcelain discs were fabricated out of which 18 each was subjected for autoglazing and overglazing. Half surface of the discs was left intact; the remaining half was roughened with medium grit diamond bur. Roughened surfaces were repolished by porcelain polishing kits (Shofu, DFS, Eve). All the surfaces were evaluated by the perthometer and SEM. Six discs from each sample were placed in human volunteer's mouth for 72 hours to evaluate the plaque accumulation. Acquired data was subjected to ANOVA comparative evaluation. RESULTS. Roughened surfaces had average roughness value of $2.88{\pm}0.1935{\mu}m$. The repolished surfaces by porcelain correction kits Shofu, DFS and Eve, average roughness value reduced to $0.6250{\pm}0.1036$, $0.9192{\pm}0.0953$, $0.9017{\pm}0.1305$ respectively. Autoglazed and overglazed surfaces showed the mean roughness value (Ra) of $0.4217{\pm}0.0685$, $0.3450{\pm}0.0729$. SEM study showed the improved surfaces when subjected for polishing. Plaque accumulation percentage was the highest on roughened surface ($93.83{\pm}6.2552%$), followed by porcelain discs polished by commercial kits. Autoglazed surfaces found to be the best surfaces with the least plaque accumulation ($0.5237{\pm}0.4209%$). CONCLUSION. All the polishing kits used in the study reduced the average roughness by approximately 77%. Corrected porcelain surfaces should ideally be reglazed, alternatively, polish the surfaces before final cementation.

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.

치과 도재용 합금과 도재간의 결합력에 관한 연구 (Study of the Bond Strength Between Dental Ceramic Alloys and Porcelain)

  • 윤일중
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.29-37
    • /
    • 1981
  • The bond strengths with ceramco porcelain were compared between precious alloy S, and non-precious alloys V.U. and R. And the changes in bond strengths of non-precious alloys with ceramco porcelain, according to surface preparations by sand blasting, longitudinal grinding, transverse grinding, and high polishing, were studied. The test specimens were prepared by firing porcelain doughnuts on the surface prepared alloy rods, and investing in dental stone. The specimens were subjected to shear loading forces. The conclusions drawn from the investigation are as follows: 1. The bond strengths with ceramco porcelain were higher in the non-precious alloys U and R, than in the precious alloy S. 2. The bond strengths were in descending order for R alloy, U alloy, V alloy, and S alloy. 3. The bond strengths were highest when the R alloy and U alloy were surface prepared by sand blasting. 4. All bond strength values were lowest when the alloy surfaces were prepared by high polishing.

  • PDF

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

치과용도재에 의한 법랑질 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL)

  • 이영국;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

활택방법에 따른 도재표면의 거칠기 비교 (ANALYSIS OF PORCELAIN SURFACE ROUGHNESS POLISHED BY VARIOUS TECHNIQUE)

  • 이규영;이청희;조광헌
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.506-513
    • /
    • 1998
  • This study was designed to compare the smoothness by glazing method with that by polishing method after 48 specimens of Ceramco II block, one of porcelain materials used for PFM, were baked according to the manufacturer's directions. The specimens were roughened with new green stone at 15,000rpm for 30 seconds and sandblasted with $25{\mu}$aluminum oxide for 15 seconds. They were divided into 4 groups at random, and 4 groups were prepared as follows : Group I : specimens were autoglazed and overpolished with polishing system. Group II : specimens were polished with only polishing system. Group III : specimens were glazed after adding glazing liquid, vitachrom 'L'-fluid (vita zahnfabrik co. Germany) to the rough surface Group V : specimens were just autoglazed Using the surface roughness tester, Ra, Rmax. and Rz were estimated 5 times per specimen, and recording process of mean value was repeated 3 times. The results were as follows : 1. The Ra of group I and group II was lower than group III and group IV (p<001). 2. There was lower value of Rz in group I and group II than group III and group IV (p<001). 3. The Rmax of group I (overpolished with polishing system after autoglazing) and group II (polished with only polishing system) was lower than group III (glazed after adding glazing liquid) and group IV (autoglazed) (p<001). 4. There was not a statistically significant difference between group I and II and between group III and IV (p>001). 5. The roughness was increase in order of group I, II, III, IV in SEM

  • PDF

연마방법에 따른 금속의 활택도에 관한 연구 - Atomic Force Microscope를 이용한 - (A STUDY ON SURFACE ROUGHNESS OF METALS ACCORDING TO FINISHING AND POLISHING PROCEDURES - AN ATOMIC FORCE MICROSCOPE ANALYSIS -)

  • 박원규;우이형;최부병;이성복
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.1-19
    • /
    • 2003
  • The surface of metals should be as smooth as possible for optimum comfort, oral hygiene, low plaque retention, and resistance to corrosion. In this study five specimens of each precious metal(type III gold alloy, ceramic gold alloy, and Ag-Pd alloy) were divided into five groups according to finishing and polishing procedures : group 1(sandblaster), group 2(group 1+stone), group 3(group 2+brown rubber), group 4(group 3+green rubber), and group 5(group 4+rouge). Six specimens of each non-precious metal(Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy) were divided into six groups: group 1(sandblaster), group 2(group 1+hard stone), group 3(group 2+electrolytic polisher), group 4(group 3+brown hard rubber point), group 5(group 4+green hard rubber point), and group 6(group 5+rouge). Considering factors affecting the rate of abrasion, the same dentist applied each finishing and polishing procedure. In addition, the surface roughness of enamel, resin, and porcelain was evaluated. The effect of finishing and polishing procedures on surface roughness of precious and non-precious metals, enamel, resin, and porcelain was evaluated by means of Atomic Force Microscope(AutoProbe CP. Park Scientific Instruments, U.S.A.) that can image the three dimensional surface profile and measure average surface roughness values of each sample at the same time. The obtained results were as follows : 1. According to finishing and polishing procedures, the surface roughness of type III gold alloy, ceramic gold alloy, and Ag-Pd alloy was decreased in the order of group 1, 2, 3, 4, and 5 (P<0.01). 2. According to finishing and polishing procedures. the surface roughness of Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy was decreased in the order of group 1, 2, 3, 4, 5, and 6 (p<0.01). 3. There was not statistically significant difference in the surface roughness among three metals of precious metals in group 1 but was significant difference in group 2, 3, 4, and 5 (P<0.05). 4. There was not statistically significant difference in the surface roughness among three metals of non-precious metals in all groups. 5. When the surface roughness of the smoothest surface of each metal, enamel. porcelain, and resin was compared, porcelain was the smoothest and the surface roughness was decreased in the order of Ni-Cr alloy. Co-Cr alloy. Co-Cr-Ti alloy, resin. Ag-Pd alloy, ceramic gold alloy type III gold alloy, and enamel (P<0.01). The results of this study indicate that the finishing and polishing procedures should be carried out in a logical, systematic sequence of steps and the harder non-precious metals may be less resistance to abrasion than are the softer precious metals.

전북지방 치과기공실 공기중 및 치과기공사의 뇨중중금속 함량에 관한 연구 (Study on Heavy Metal Contents in Air of Den Tal Laboratories and Urine of Dental Laboratory Technicians in CHONBUK Area)

  • 이정오;이종섭;유인수
    • 한국환경보건학회지
    • /
    • 제16권2호
    • /
    • pp.97-103
    • /
    • 1990
  • For this study, I used the urine of 100 dental laboratroy technicians and 24 students in Chonbuk region. The purposes of this study were to investigate concentrations of cadmium (Cd), nickel (Ni) and chromium (Cr) in the air of dental laboratories. The results were as follows: 1. The concentrations of Cd is 0.0115mg/m$^{3}$ in the porcelain part, 0.0090mg/m$^{3}$ in the polishing part, that of Ni is 0.2864mg/m$^{3}$ in the porcelain part, 0.3188mg/m$^{3}$ in the polishing part, that of Cr is 0.0448mg/m$^{3}$ in the porcelain part, 0.1032mg/m$^{3}$ in the polishing part. 2. The concentrations of Cd, Ni and Cr in the technicians urine are 3.06 $\mu$g/l, 44.55 $\mu$g/l and 14.58 $\mu$g/l. Those of students, urine as the control group are 1.93 $\mu$g/l, 19.05 $\mu$g/l and 7.48 $\mu$g/l. There is significant difference between experimental group and control group (P < 0.01). 3. Watching for age and working place, 31-40 years age group reveals the highest group in the concentrations of Cd. Over 41 year age group represents the highest group in the concentrations of Ni and Cr (P < 0.01) The concentration of Cd turns up the highest in the partial part and that of Ni and Cr appears the highest in the polishing part (P < 0.01). Looking into working age, over 7 year group is the highest group in the concentrations of all investigated (P < 0.05).

  • PDF