• Title/Summary/Keyword: Porcelain layer thickness

Search Result 11, Processing Time 0.021 seconds

THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS (도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향)

  • Seong Dong-Hwan;Lee Im-Gi;Sohng Jin-Won;Bok Won-Mi;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

Spectrophotometic analysis of the influence of substrate on the color of dental ceramics (하부구조물 및 두께에 따른 치과 수복용 세라믹의 색조에 대한 분광측색분석)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.96-103
    • /
    • 2015
  • Purpose: The purpose of this study was to spectrophotometrically evaluate the influence of porcelain layer thickness and substructure. Materials and Methods: Four groups of porcelain specimens (metal and ceramic substructure) was prepared for analysis. Color parameters were measured with spectrophotometer and color difference (${\Delta}E*$) were calculated. T-test and one-way ANOVA test were used to find out significant difference and Tukey test was used to identify where the difference ware. Results: Increasing the thickness of porcelain decreased values (P < 0.05). Increasing the thickness of porcelain on ceramic substructure decreased the $a^*$ (P < 0.05) but, the $b^*$ were not statistically different. Total color difference (${\Delta}E*$) were below 1 when the difference of porcelain thickness were 0.5 mm. Conclusion: The thickness of porcelain are the factor effecting on color. This study will help the color are controlled by changing the thickness of porcelain clinically.

Sintering of Layer Structure Materials: Effect of Starting Material on Sintering Defects and Residual Stress (층상구조 재료의 소결: 출발물질이 소결결함 및 잔류응력에 미치는 영향)

  • 정연길
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.1
    • /
    • pp.61-68
    • /
    • 1999
  • To analyze several defects and residual stress in sintering of layer structure materials, multiayer materials with TZP/SUS and ZT/SUS, and bilayer materials with porcelain/alumina and porcelain/Y-TZP were fabricated by sintering method. Multilayer materials prepared by pressureless sintering show the sintering defect such as warping, splitting, cracking originated from the difference of sintering shrinkage between each layer, which could be controlled by the adjustment of number and thickness in interlayer. In tape casting, a certain pressure given during sintering relaxed the sintering defects, specially warping. The residual stress in bilayer was examined with Vickers indentation method. A small tensile stress in porcelain/alumina and a large compressive stress in porcelain/Y-TZP were generated on the porcelain interface due to the thermal expansion mismatch, which affected the strength of bilayer materials. As a consequence, the sintering defects of multilayer materials and the residual stresses of bilayer materials were dominantly influenced on material design and starting material constants.

  • PDF

The Material Analysis and Conservation of Porcelain Enamel - Focus of Porcelain Enamel Excavated at Former President Yoon Bosun's Birthplace -

  • Lee, Jung-Min
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.33-40
    • /
    • 2019
  • During the conservation and maintenance of the birthplace center yard of President Asan Yoon Bosun, four porcelain enamel dishware were excavated from the central yard well. The glaze layer of excavated enamel was severely damaged; hence, the conservation process was done rapidly. In addition, scientific investigation and analysis were conducted to confirm the material properties of the glaze layer. It was confirmed that the outer surface was inverted and dried, while the inner surface was upright and fired during the glazing and drying process by measuring the film thickness. By examining the breakup phenomenon, the breaking up of the white enamel on the colored enamel was confirmed. This indicates that the colored glaze rose to the surface depending on the density of the colored glaze and white glaze. The investigation of the cross-section of the film confirmed that the lower layer formed according to the bonding properties with metal during the glazing process. Analysis of the constituents of the identified lower layer confirmed that there are differences between the specific components of the metal oxide of the lower layer and the surface color development of the upper layer.

Effects of Contact Damage and Residual Stress in Dental Layered Ceramics (치아응용을 위한 층상 세라믹스에서의 접촉손상 및 잔류응력의 영향)

  • 정종원;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.288-293
    • /
    • 2000
  • Effects of contact damage and residual stress for two kinds of dental restorative layered ceramics, porcelain/alumina and porcelain/zirconia bilayers, were observed with Hertzian and Vickers indentation methods. Indentation stress-strain behavior of each material, strength degradation of the coating material, and crack propagation behavior in the coating layer after Vickers indentation were examined by an optical microscope. As a result, porcelain as coating materials showed the classical brittleness. It was inferred that damage and strength in two bilayer system were dependent on thermal expansion mismatch between the coating material and the substrate, which affected the strength degradation. Residual stress resulting from thermal expansion mismtch was formed in the coating layer, and specially in the case of porcelain/zirconia, residual stress was eliminated as coating thickness decreased.

  • PDF

A study on interfacial characteristics of Ni-Cr alloy by Nb content for Porcelain Fused to Metal Crown (금속소부도재관용 Ni-Cr 합금에 첨가된 Nb이 계면특성에 미치는 영향)

  • Kim, Chi-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.97-104
    • /
    • 2005
  • The effect of Nb on interfacial bonding characteristics of Ni-Cr alloy for porcelain fused to metal crown (PFM) has been studied in order to investigate oxide layer. A specimens, which is 0.8mm in thickness, were fired at 1,000$^{\circ}C$ with four tests such as air, vacuum, air for 5 minutes and vacuum for 5 minutes in order to examine an oxide behavior of alloy surface generated by the adding of Nb to be controlled at a rate of 0, 1, 3 and 5. It observed oxide film form of the fired specimens with optical microscope and scanning electron microscope (SEM), and chemical formation of them with energy disperse X-ray spectroscopy (EDX). The other specimens, which is 2mm in thickness, were fired at 1,000$^{\circ}C$ with air and vacuum in order to analyze the diffusion behaviors of alloy-porcelain interface by X-ray dot mapping. The results of this study were as follows: 1. The observation of microstructure of specimens by SEM showed that the more Nb content is high, the more much intermediate compound of rich Nb is observed. 2. The surface morphology of oxide film is most dense in 3% Nb. The heat treatment in air constitutes denser oxide film than heat treatment under vacuum. 3. The diffusion behavior of oxide layer by X-ray dot mapping showed that Si, Al of porcelain diffuse toward metal.

  • PDF

Effect of cobalt sulfate contents on the ceramic surface coating using spray technique (스프레이 기술을 이용한 세라믹 표면 코팅에 대한 황화코발트 첨가량의 영향)

  • Park, Hyun;Kim, Kyung-Nam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.6
    • /
    • pp.256-260
    • /
    • 2014
  • This study was carried on the phenomena in reactivity with the clay surface according to the thickness of the cobalt component coating. In the coated specimen, it was observed that the cobalt component was spreaded to diffuse with a constant thickness from the surface of it and the diffusion layer at the white porcelain soil was more increased with the increase of the amount of cobalt sulfate than at the celadon porcelain one. It was evaluated that the color of the surface on the coated specimen at the white porcelain soil was changed from grayish blue to blue and the $L^*$ value was decreased from 51.78 to 37.61 and also in the case of the coated specimen in celadon porcelain soil, $L^*$ value was from 53.91 to 38.93 and the color was from dark olive gray to dark gray. The physical properties of the specimen were characterized by X-ray diffraction, Scanning electron microscope, Dilatometer, TG-DTA, UV-vis spectrophotometer and HRDPM.

Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic (지르코니아 코아의 색조부여가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Baek, Ki-Hyun;Woo, Yi-Hyung;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.409-419
    • /
    • 2008
  • Statement of problem: At all times people have tried to fabricate tooth restorations using tooth colored materials. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. The basic color of zirconia is white to ivory. The color can be partially adapted by veneering it with ceramic materials. However, it would be better if the substructure could already be adapted to the basic color shade of neighboring teeth. By adaptation to the basic shade, it can help to reduce the necessary layer thickness of the veneer ceramic to achieve the desired color. Purpose: The purpose of this study was to spectrophotometrically evaluate the influence of shading of zirconia core on the final shade of all-ceramic restorations using the CIE $L^{*}a^{*}b^{*}$ system. Material and methods: Core specimens (n = 20 per group) of Lava Frame Zirconia, KaVo Everest Zirconia, Digident CAD/CAM Zirconia were fabricated at 20 mm in diameter and 0.5 mm in thickness. Halves of each groups were shaded in A3 color. These core specimens were veneered with A3 porcelain of the recommended manufacturer at thickness of 0.5 mm. CIE $L^{*}a^{*}b^{*}$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan) at 0.5 mm, 0.4 mm, 0.3 mm in thickness. Color differences were calculated using the equation ${\Delta}E^{*}=[({\Delta}L^{*})2+({\Delta}a^{*})2+({\Delta}b^{*})2]1/2$. Results: 1. In the case where porcelain layer has a thickness of 0.5 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, however Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 2. When the thickness of porcelain layer decreased from 0.5 mm to 0.4 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, on the other hand Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 3. When the thickness of porcelain layer decreased from 0.5 mm to 0.3 mm, clinically perceived color differences were observed from all three groups. Conclusions: Ziroconia system, which is possible to allow shade on core, are thought to be much more favorable to reproduce natural shade compared to systems that is impossible to give shade. Therefore, clinicians ought to choose adequate system for certain clinical situation by considering above specific character.

A Study on EPMA on Ni-Cr Alloy by Nb content for Porcelain Fused to Metal Crown (Nb이 첨가된 금속소부도재관용 Ni-Cr 합금 표면의 EPMA 관찰)

  • Kim, Chi-Young;Choi, Sung-Min;Cho, Hyeon-Seol
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • The effect of Nb on interfacial bonding characteristics of Ni-Cr alloy for porcelain fused to metal crown (PFM) has been studied in order to investigate oxide layer. A specimens of Ni-Cr alloy, which is 0.8mm in thickness, within the porcelain furnace of 1,000$^{\circ}C$ with four tests such as air, vacuum, air for 5 minutes and vacuum for 5 minutes in order to examine an oxide behavior of alloy surface generated by the adding of Nb to be controlled at a rate of 0, 1, 3 and 5. Oxide film was observed form of the fired specimens with scanning electron microscope (SEM), and at the same time it measured Electron Probe Micro Analyzer (EPMA). The result of this study were as follows: 1. Cr oxide film and Nb oxide film were observed from the surface of specimen to be controlled at a rate of Nb 1%. 2. Nb oxide film was observed from the interface of specimens to be controlled at a rate of Nb 1% and 3%. 3. The stability of oxide films that treated in air were more stable than treated under vacuum.

  • PDF

Contact Damage and Fracture of Poreclain/Glass-Infiltrated Alumina Layer Structure for Dental Application (치아 응용을 위한 /유리침윤 알루미나 이중 층상구조의 접촉손상 및 파괴)

  • 정연길;여정구;최성설
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1257-1265
    • /
    • 1998
  • Hertzian contact tests were used to investigate the evolution of fracturedamage in the coating layer as functions of contact load and coating thickness by studying crack patterns in porcelain on glass-infiltrated alumina bilayer system conceived to simulate the crown structure of a tooth. Cone cracks initiated at the coating top surface without delamination at interface and crack propagation to substrate. Preferentially the cracks made multi-cracks at the coating top surface rather than proceeding to interface. The cracks were highly stabilized with wide ranges between the loads to initiate first cracking and to cause final failure im-plying damage-tolerant capability. Finite element modelling was used to evaluate the stress distribution. Maximum tensile stress were responsible for the cracking at the coating layer and had a profound influence on the crack pattern and fracture damage in the layered structure materials.

  • PDF