• 제목/요약/키워드: Porcelain Insulator

검색결과 140건 처리시간 0.032초

비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향 (The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators)

  • 김찬영;송일근;김주용;한재홍;김동명;이병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF

154kV 송전용 자기애자의 ESDD 오손특성에 관한 연구 (ESDD Contamination Characteristics for 154kV Transmission Porcelain Insulator)

  • 박재준;최인혁;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.210-211
    • /
    • 2006
  • 154kV송전용 자기현수애자 오손특성을 구하기 위하여 자체 제작된 챔버 내에서 3개의 자기애자를 현수하여 누설전류파형의 변화를 관찰하였다. 154kV 송전용자기 애자의 신뢰성평가를 위하여 ESDD 레벨에 따른 누설전류 파형 및 최대값 변화양상을 단계적 승압을 통하여 파형을 계측하였다. ESBD 레벨에 따른 누설전류 파형의 최대값이 아크방전의 영향이 없을 경우는 일정한 규칙으로 증가하였고, ESDD레벨이 높아지면서 아크방전의 발생은 주파수 분석을 통한 고조파성분의 변화양상을 볼 수 가 있다.

  • PDF

송전급 자기재 애자의 알루미나 증가에 따른 특성 분석 (A Characteristic Analysis of porcelain insulator for Transmission by additional Alumina)

  • 최인혁;박준호;강병규;이동일;원봉주;김원진;오창효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1484-1485
    • /
    • 2006
  • Alumina 첨가량의 변화에 따라 국산 경년품 애자와 신품 애자의 특성을 분석하고, 외국산 신품애자와 비교분석하였다. 그 결과 알루미나가 17% 첨가된 2001년도 자기애자가 알루미나 첨가량이 m%된 2004년 신품애자에 비하여 기계적 특성이 10%정도 낮았다. 또한, 2001년도에 제조한 애자의 자기 상대밀도는 이론밀도의 96%에 도달하였으나 2004년도에 제조한 애자의 상대 밀도는 이론 밀도의 98%에 도달하였으며, 애자의 균일성을 나타내는 Qs 값은 5.01로 높게 나타났다.

  • PDF

실 포설 환경에 노출된 송전용 고분자애자의 평가 (Analysis of Polymeric Insulators Exposed to In-service Conditions)

  • 이상진;연복희;배경무;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.248-250
    • /
    • 2004
  • We have investigated the surface state of 154kV polymeric insulators exposed to in-service conditions for about five years. In order to evaluate surface aging of silicone rubber exposed to real field environments, we used various analytic methods such as contact angle, ATR-FTIR, SEM-EDS. Although contaminants were accumulated on weathershed surface, polymeric insulator has retained its intrinsic surface hydrophocity. In addition, ATR-FTIR confirmed the diffusion layer of a low molecular weight silicone fluid on surface layer and no surface cracking and chalking were Indicated by SEM. Polymeric insulators have still retained their improved pollution performance over porcelain insulators. That will lead to very low frequency of flashovers throughout their useful life, often under contaminated conditions.

  • PDF

Seismic mitigation of substation cable connected equipment using friction pendulum systems

  • Karami-Mohammadi, Reza;Mirtaheri, Masoud;Salkhordeh, Mojtaba;Mosaffa, Erfan;Mahdavi, Golsa;Hariri-Ardebili, Mohammad Amin
    • Structural Engineering and Mechanics
    • /
    • 제72권6호
    • /
    • pp.785-796
    • /
    • 2019
  • Power transmission substations are susceptible to potential damage under seismic excitations. Two of the major seismic failure modes in substation supplies are: the breakage of brittle insulator, and conductor end fittings. This paper presents efficient isolation strategies for seismically strengthening of a two-item set of equipment including capacitive voltage transformer (CVT) adjacent to a Lightning Arrester (LA). Two different strategies are proposed, Case A: implementation of base isolation at the base of the CVT, while the LA is kept fixed-base, and Case B: implementation of base isolation at the base of the LA, while the CVT is kept fixed-base. Both CVT and LA are connected to each other using a cable during the dynamic excitation. The probabilistic seismic behavior is measured by Incremental Dynamic Analysis (IDA), and a series of appropriate damage states are proposed. Finally, the fragility curves are derived for both the systems. It is found that Friction Pendulum System (FPS) isolator has the potential of decreasing flexural stresses caused by intense ground motions. The research has shown that when the FPS is placed under LA, i.e. Case B (as oppose to Case A), the efficiency of the system is improved in terms of reducing the forces and stresses at the bottom of the porcelain. Several parametric studies are also performed to determine the optimum physical properties of the FPS.

가공송전선로 폴리머애자 적용 개선 방안 (The Application Improvement Plan of Polymer Insulators for Overhead Transmission Lines)

  • 민병욱;김태영;최진성;신승범;이시영;원경배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.465-466
    • /
    • 2011
  • The global trend is to make transmission lines light weight and compact by using insulators and other equipment made of advanced materials. In Korea, the diversification of insulators supply route has begun in order to obtain price competitiveness. In May 1999, polymer insulators were finally introduced for the first time and installed to the 154kV transmission lines. After that, the construction and procurement standards were made and domestic polymer insulators were developed. And then, foreign and domestic manufacturers were registered in KEPCO as qualified insulator suppliers. As of 2010, purchasing polymer insulators by competitive bidding from foreign and domestic manufacturers has been possible. For this reason, it was decided to reduce the use of porcelain insulators and increase the use of polymer insulators taking the installation price into consideration

  • PDF

Pulse current method를 이용한 154kV급 송전용 자기 애자의 누설 전류의 펄스 분석 (Leakage Current Pulse analysis of Porcelain Insulator at 154kV Transmission Line by use of Pulse Current Method)

  • 이슬기;류철휘;이방욱;최광범;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.129-130
    • /
    • 2008
  • 송전선로에 설취된 애자들은 지속적인 전기적 기계적 스트레스에 노출되어 있기 때문에 여러 환경적 요인으로 인해 애자 표변의 열화가 가속된다. 이와 같은 애자의 표면 열화는 dryband를 형성하게 되고 지속적인 애자 표면상의 dryband와 누설 전류 증가의 상호 작용은 애자의 섬락를 일으키는 원인이 된다.[1][2] 이러한 연구의 결과 고전압용 애자로 유입되는 누설 전류는 애자 열화의 정도를 평가할 수 있는 매우 중요한 parameter임을 알 수 있다. 따라서 고전압용 애자의 누설전류를 분석하고 취득하여 애자의 열화 평가 및 이로 인해 발생할 수 있는 결함 애자의 검출에 대한 연구가 절실히 요구되고 있다, 본 논문에서는 고전압용 애자 중 자기애자의 누설전류 특성을 조사하기 위해 자체 제작한 실험 챔버, AC 내전압기, 전류센서r, 오실로스코프, PC등으로 구성된 실험 시스템을 구축하였고, 데이터 분석을 위한 S/W로서 LabView를 사용하였다. 그에 따른 실험 결과로서 정상 애자련과 결함 애자를 포함한 애자련의 누설전류 데이터를 취득하여 본 연구에서 제시한 알고리즘을 통해 분석함으로써 정상 애자 내의 결함 애자 포함 여부를 판별할 수 있었다.

  • PDF

EPDM/Silicone 복합 절연체의 표면특성과 전기적 특성 (Surface and Electrical Properties on EPDM/Silicone Composite Insulator)

  • 심대섭;박성균;김범진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.92-95
    • /
    • 2001
  • 고분자 복합체 절연재료는 porcelain 이나 glass 같은 세라믹 소재의 재료와 비교하여 옥외사용 시간의 관점에서 더 뛰어난 특정을 발휘한다. 그러나 노화되었을 때, 이들 옥외용 절연재료의 성질은 발수성이나 흡수성등과 같은 절연재료의 표면특성에 의해 변화한다. 이러한 표면특성의 변화는 누설전류에 의한 트래킹 (tracking), 침식 (erosion) 및 섬락현상(flashover) 등의 유전체 파괴에 이르게 한다. 본 연구에서는 고분자 복합체 절연재료로 널리 이용되고 있는 EPDM의 발수특성을 향상시키기 위해 기존에 이용되던 무기물 첨가제인 alumina hydrate(ATH)이외에 발수성이 뛰어난 실리콘 고무를 상용화제를 이용하여 블렌드하고, 각종 유기 첨가제 및 무기물 보강제를 이용하여 EPDM/Silicone 복합체를 제조하였다. EPDM/Silicone 복합체의 인장강도 및 유전강도는 실리콘의 함량이 증가할수록 낮아졌으며, 촉진 노화시험을 실시한 결과 $120^{\circ}C$까지 인장강도 및 신율을 유지하였다. 유전강도의 측정결과 복합체의 접촉각과 표면에너지 측정결과 Silicone 고무의 함량이 증가할수록 접촉각은 증가하고, 표면에너지는 낮아졌다. 경사평판법에의한 내트래킹성 측정결과 실리콘 함량이 증가할수록 내트래킹성은 우수하였으며, 실리콘 함량이 30%인 복합체에서는 트래킹 및 침식이 진행되지 않았다.

  • PDF

Salt fog 시험에서 silicone rubber에서 발생하는 방전 전류의 특성 (The surface discharge performance of silicone rubber in the Salt fog test)

  • 강성화;박영국;이광우;김완수;이용회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.565-569
    • /
    • 1999
  • In these days, the silicone insulators have been increasingly studied and applied for outdoor insulators because it has superior characteristics than porcelain and glass insulators, which have been used for outdoor insulators. First of all, The excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contamination and wet conditions. This is because of the presence of low molecular weight mobile fluid in the silicone rubber which diffuses to the surface and to above the contamination layer. But, the leakage current and some surface discharge occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current and the discharge current are important to estimate the condition of the silicone rubber surface. In this paper, the average leakage current, the relation of surface discharge current and phase angle were study to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach

  • Narayanan, V. Jayaprakash;Sivakumar, M.;Karpagavani, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1677-1685
    • /
    • 2014
  • Major problem in the high voltage power transmission line is the flashover due to polluted ceramic insulators which leads to failure of equipments, catastrophic fires and power outages. This paper deals with the development of a better diagnostic tool to predict the flashover and pollution severity of power transmission line insulators based on the wavelet transform and fuzzy c-means clustering approach. In this work, laboratory experiments were carried out on power transmission line porcelain insulators under AC voltages at different pollution conditions and corresponding leakage current patterns were measured. Discrete wavelet transform technique is employed to extract important features of leakage current signals. Variation of leakage current magnitude and distortion ratio at different pollution levels were analyzed. Fuzzy c-means algorithm is used to cluster the extracted features of the leakage current data. Test results clearly show that the flashover and pollution severity of power transmission line insulators can be effectively realized through fuzzy clustering technique and it will be useful to carry out preventive maintenance work.