• 제목/요약/키워드: Pool water

검색결과 544건 처리시간 0.031초

유한요소법에 의한 2차원 하천 흐름 모형의 개발 (Two-Dimensional River Flow Analysis Modeling By Finite Element Method)

  • 한건연;김상호;김병현;최승용
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.425-429
    • /
    • 2006
  • The understanding and prediction of the behavior of flow in open channels are important to the solution of a wide variety of practical flow problems in water resources engineering. Recently, frequent drought has increased the necessity of an effective water resources control and management of river flows for reserving instream flow. The objective of this study is to develop an efficient and accurate finite element model based on Streamline Upwind/Petrov-Galerkin(SU/PG) scheme for analyzing and predicting two dimensional flow features in complex natural rivers. Several tests were performed in developed all elements(4-Node, 6-Node, 8-Node elements) for the purpose of validation and verification of the developed model. The U-shaped channel of flow and natural river of flow were performed for tests. The results were compared with these of laboratory experiments and RMA-2 model. Such results showed that solutions of high order elements were better accurate and improved than those of linear elements. Also, the suggested model displayed reasonable velocity distribution compare to RMA-2 model in meandering domain for application of natural river flow. Accordingly, the developed finite element model is feasible and produces reliable results for simulation of two dimensional natural river flow. Also, One contribution of this study is to present that results can lead to significant gain in analyzing the accurate flow behavior associated with hydraulic structure such as weir and water intake station and flow of chute and pool.

  • PDF

지하철 객차 내 환기 속도가 고압 미세물분무 화재제어 시스템의 성능에 대한 실험평가 (An Experimental Evaluation for the Effect of Ventilation Velocity in Subway Train on Performance of a High Pressure Water Mist Fire Suppression)

  • 김동운;배승용;김동석;박원희;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1307-1312
    • /
    • 2007
  • This experiments are performed to investigate the effect of ventilation velocity on a high pressure water mist fire suppression in subway train. The experiment is conducted in half scale modeled train of a steel-welled enclosure (8.0m*2.4m*2.1m). The ventilation velocity is controlled by the ventilation duct through an inverter in the range of 0 to 2 m/s. The coverage-radius and an injection angle of an high pressure water mist system are measured. The mist nozzle with 7-injection holes is operated with pressure 80 bar. The heptane pool fires are used. The fire extinguishment times and the temperatures are measured for the ventilation velocities. In conclusion, because the momentum of injected water mist is more dominant than that of ventilation air, the characteristics of water mist, the fire extinguishment times and the temperatures are affected very little by ventilation velocity.

  • PDF

미분무수 특성이 화재억제 메커니즘에 미치는 영향에 대한 수치해석적 연구 (Numerical Study on the Effects of Spray Properties of Water Mist on the Fire Suppression Mechanism)

  • 배강열;정희택;김형범
    • 한국분무공학회지
    • /
    • 제22권4호
    • /
    • pp.175-184
    • /
    • 2017
  • The numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m^3$ and a water mist nozzle that be installed 1.8 m from fire pool. In the present study, the parameters of nozzle for simulation are the droplet size and the spray velocity. The droplet size influences to fire flume on fire suppression more than the spray velocity because of the effect of the terminal velocity. The optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20 m/s respectively.

영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링 (Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire)

  • 황원준;김황진;이성은;김성원;오규형
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.84-89
    • /
    • 2009
  • 본 연구에서는 미분무수 노즐을 이용하여 소화시간에 영향을 미치는 인자들을 변화시키며 소화실험을 수행하였다. 주요 인자는 화염의 위치와 노즐 중심으로부터의 거리, 미분무 입자의 크기, 노즐의 설치 높이, 개구부 여부 등이었다. 소화실험 결과로부터 각 인자들 간의 상호작용과 소화에 대한 민감도를 Mini tab을 이용하여 분석하여 미분무수 소화시스템의 최적 소화모델을 도출하였다. 소화시간에 가장 큰 영향을 미치는 인자는 노즐 중심으로부터의 거리이며 개구부의 여부는 다른 인자들에 비하여 소화시간에 미치는 영향도가 적게 나타났다.

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • 제25권4호
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

낙동강 8개 보에서 기상수문·기초수질 및 우점조류의 시공간 종적 변동성 (Spatiotemporal and Longitudinal Variability of Hydro-meteorology, Basic Water Quality and Dominant Algal Assemblages in the Eight Weir Pools of Regulated River(Nakdong))

  • 신재기;박용은
    • 생태와환경
    • /
    • 제51권4호
    • /
    • pp.268-286
    • /
    • 2018
  • 조절하천의 낙동강에서 겪고 있는 부영양화와 조류 대발생(유해남조의 녹조현상 및 담수적조)은 국내외적으로 가장 급속하게 확대되고 있는 수질문제이며, 다양한 집단에서 지대한 관심을 가지게 한 분야 중 하나이다. 본 연구는 2013년 1월부터 2017년 7월까지 낙동강의 8개 보 pools에서 주요 수질 환경요인을 주 간격으로 조사하였고, 우점조류와 상호 관련성을 비교 분석하였다. 연강수량은 2016년(보 평균 940.7 mm)에 많았고, 2015년(672.8 mm)에 적었다. 장마 폭염기 (6~9월) 강우는 총강수량의 48.1%이었고, 상 하류간에 차이가 컸다. 총방류량 중 소수력발전, 월류 및 어도가 차지하는 비율은 각각 37.4%, 60.1%, 2.5%로서 홍수기를 제외하고 발전방류에 의한 비중이 매우 컸다. 방류량은 대부분 유입량에 비례하였으나, 취수량이 집중되는 보에서 다른 양상도 관찰되었다. 이것은 수위강하, 물 교환율과 연관되었고, 유해남조와 담수적조의 대발생에 심각한 영향을 초래하였다. 수온과 DO 농도의 변화는 기상 수문학적 영향이 지배적이었는데, 온도변화 뿐만 아니라 강우의 특성에 따라 변화 양상이 포착되었다. Chl-a의 평균 농도 (최대값)는 SAJ~GAJ와 DAS~HAA구간에서 각각 $17.6mg\;m^{-3}$ ($98.2mg\;m^{-3}$), $29.6mg\;m^{-3}$ ($193.6mg\;m^{-3}$)이었고, 하수의 영향이 절대적인 하류부에서 증가하는 경향이 현저하였다. 우점조류의 분류군 조성은 총 48속으로 규조 14속, 남조 8속, 녹조 18속 및 편모조 8속으로 각각 구성되었다. 유해 녹조현상과 담수적조의 주요 원인조류는 각각 남조 Microcystis와 규조 Stephanodiscus 개체군이었다.

V형 여울에서 발생하는 세굴에 관한 실험 연구 (An Experimental Study on Scour at V-shaped Riffle)

  • 유대영;박정환;우효섭
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.507-520
    • /
    • 2003
  • V형 여울은 하천 양안에 설치하여 여울의 가운데로 물의 흐름을 집중시켜 하도 중앙 직하류에 세굴로 인한 소(pool)를 형성하는 역할을 하는 인공 여울이다. V형 여울의 설치 목적은 평탄화된 하도에 소를 형성시켜 갈수시 어류의 서식처 노는 피난처를 제공하고, 홍수시에는 유속이 약한 구간을 발생시켜 어류의 피난처를 제공하는 것이다. 본 연구에서는 V형 여울의 수리 모형 실험을 실시하여 각 조건에 따른 세굴심을 측정하여 세굴 특성을 분석하였고, 나아가 수리량 조건 및 V형 여울 형태와 세굴 간의 정량적인 관계를 실험 결과로부터 도출하였다. 또한 V형 여울과 형태가 유사한 수제에서의 세굴심에 대한 기존의 연구 결과와 V형 여울의 경우를 비교하였다. 그 결과 Breusers와 Raudkivi(1991)가 제안한 수제에서의 세굴심 예측식은 V형 여울에서의 세굴심을 과소평가하지만 V형 여울께서의 세굴 특성을 일부 반영하는 것으로 나타났다. V형 여울의 세굴에 영향을 주는 인자들의 무차원화를 통해 V형 여울에서의 세굴심 예측식을 제안하였고 제안된 예측식은 V형 여울의 적용에 있어서 세굴심을 추정하는데 사용될 수 있고 판단된다. V형 여울의 세굴에 지배적인 영향을 주는 인자는 여울 중앙에서의 프루드 수이고, 그밖에 여울과 흐름의 각도와 여울 개구부의 폭도 부분적으로 영향을 준다.

다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구 (Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity)

  • 강동규;이요한;서훈;정동수
    • 대한기계학회논문집B
    • /
    • 제37권4호
    • /
    • pp.343-352
    • /
    • 2013
  • 본 연구에서는 열전달 표면의 형상과 그 위에서의 유동 속도의 변화에 따른 풀 비등 열전달계수의 변화를 살펴보기 위해 평판, 낮은 핀, Thermoexcel-E, Turbo-B 표면을 사용하여 유동 속도를 변화시켜가며 임계 열유속까지 열전달계수를 측정하였다. 작동 유체로는 증류수를 사용하였고 사각 평면 히터($9.53{\times}9.53mm$)를 이용하여 네 가지 표면에서 임계 열유속까지의 데이터를 얻을 수 있도록 장치를 제작하였고 $60^{\circ}C$에서 유동 속도를 0, 0.1, 0.15, 0.2m/s로 변화시켜가며 데이터를 취했다. 실험 데이터를 보면 모든 표면에서 유동이 있을 때의 임계 열유속은 유동이 없을 때에 비해 높은 것으로 나타났다. 또한 표면적의 증가와 기포 이탈에 충분한 핀 간격 등으로 인해 낮은 핀 표면의 임계 열유속은 평판이나 Turbo-B, Thermoexcel-E 표면보다 훨씬 놓았고 평판에 비해서는 무려 5배 정도의 향상을 보였다. 한편 대형 냉동기의 증발기용으로 개발된 Turbo-B와 Thermoexcel-E 표면은 물에서 기포의 이탈 지름이 크므로 열전달계수와 임계 열유속 모두 예상보다 큰 효과를 나타내지 않았다. $50kW/m^2$이하의 저열유속에서는 모든 표면에 대해 유동 속도 증가에 따라 열전달계수가 증가하였다. 결론적으로 핵발전소의 증기발생기에 적용하기에는 낮은 핀 형상의 표면이 가장 좋은 것으로 나타났다.

장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析) (Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle)

  • 이태영;하정우;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.90-96
    • /
    • 1984
  • 장주기핵연료(長週期核燃料) 노심기법(爐心技法)에 의한 사용후핵연료(使用後核燃料)가 기존(旣存) 사용후핵연료저장시설(使用後核燃料貯藏施設)의 설계변경(設計變更)없이 동(同) 시설(施設)에 수용(受容) 가능(可能)한지를 결정(決定)하기 위하여 저장시설(貯藏施設)에서의 예상(豫想) 방사선피폭선량률(放射線被曝線量率) DLC-23/CASK (22n, 18g) 단면적(斷面積)자료(資料)와 ANISN-W 전산(電算)코드로 계산(計算)하여 설계기준치(設計基準値)와 비교(比較) 검토(檢討)하였다. 사용후핵연료내(使用後核燃料內)의 방사능량(放射能量) 및 감마선스펙트럼은 핵연료교체(核燃料交替)모델에 따라 ORIGEN 전산(電算)코드로 계산(計算)하였다. 방사선량률(放射線量率)의 계산(計算)에 있어서 저장조(貯藏槽)의 기하학적(幾何學的) 모델은 무한평판모형(無限平板模型)이며 저장(貯藏)된 사용후핵연료(使用後核燃料)의 구성물질(構成物質)과 방사선원(放射線源)은 핵연료집합체내(核燃料集合體內)에 균일(均一)하게 분포(分布)되었다고 가정(假定)하였다. 사용후핵연료저장조(使用後核燃料貯藏槽)에 저장(貯藏)된 핵연료집합체(核燃料集合體) 및 저장용수중(貯藏用水中) 방사성핵종(放射性核種)에 의한 방사선량률(放射線量率)의 계산(計算) 결과(結果)는 정상(正常) 및 사고수면시(事故水面時) 계산(計算)된 방사선량률(放射線量率)이 설계기준치(設計基準値)를 만족(滿足)시켜주는 것으로 나타났다.

  • PDF

RIVER2D를 이용한 개방형 하도습지의 물리서식처 분석 (Analysis of Aquatic Physical Habitat of Channel Connected Pool Using RIVER2D, Korea)

  • 정상준;안홍규;임동균
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.2083-2087
    • /
    • 2009
  • 본 연구에서는 대전에 위치한 갑천을 대상으로, 하도 내 생물서식처를 10개의 유형으로 분류하였고, 다음 단계로 2차원 수리모형인 RIVER2D를 이용하여 10개 유형의 생물서식처 중 '개방형하도 습지'를 대상으로 수생 물리 서식처의 잠재적 가치를 분석하였다. 본 연구를 통하여 2차원 수리모델인 RIVER2D는 특정 복원 목표 어류 종의 수생물리서식처 조건 평가에 적용하기에 적합한 것으로 나타났다. 개방형 하도습지는 어류 서식처로서 평균이상의 잠재적 가치를 가지고 있었으며 이는 목표 종인 피라미를 통해 검증하였다. 또한 이 모델을 보다 유용하게 운용하기 위해서는 다양한 어류에 대한 풍부한 현장 데이터 자료의 수집 및 확립을 통해 각각의 HSI 수립이 필요하다. 또한 계절적 영향에 의한 수위변화, 지역적인 여건의 차이 등이 반드시 고려되어야 할 것이다.

  • PDF