• Title/Summary/Keyword: Pool configuration

Search Result 26, Processing Time 0.024 seconds

Distributed Address Configuration Mechanism Using Address Pool in MANET (MANET 환경에서 주소 영역기반 주소할당 분산기법)

  • Ahn, Sang-Hyun;Lim, Yu-Jin;Yu, Hyun
    • The KIPS Transactions:PartC
    • /
    • v.16C no.6
    • /
    • pp.753-760
    • /
    • 2009
  • As it becomes increasingly important that Internet access is available anywhere at any time, providing MANET (Mobile Ad-Hoc Network) with the Internet access attracts more attention. The existing DHCP (Dynamic Host Configuration Protocol) address configuration schemes require message exchanges between MANET nodes and the DHCP server through multi-hop routes. Messages can be easily dropped in the wireless multi-hop communication environment and the address configuration may be instable and need long delay. In this paper, we propose a new address configuration scheme using the concept of address pool allocation. In the proposed scheme, the DHCP server assigns a part of its address pool to a node instead of a single address and the node can assign a part of its own address pool to its neighbor nodes. Through simulation studies, we show that our scheme yields about 77% of the address configuration delay and 61% of the control message overhead of the existing DHCP based mechanism.

Hybrid Recommendation Algorithm for User Satisfaction-oriented Privacy Model

  • Sun, Yinggang;Zhang, Hongguo;Zhang, Luogang;Ma, Chao;Huang, Hai;Zhan, Dongyang;Qu, Jiaxing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.10
    • /
    • pp.3419-3437
    • /
    • 2022
  • Anonymization technology is an important technology for privacy protection in the process of data release. Usually, before publishing data, the data publisher needs to use anonymization technology to anonymize the original data, and then publish the anonymized data. However, for data publishers who do not have or have less anonymized technical knowledge background, how to configure appropriate parameters for data with different characteristics has become a more difficult problem. In response to this problem, this paper adds a historical configuration scheme resource pool on the basis of the traditional anonymization process, and configuration parameters can be automatically recommended through the historical configuration scheme resource pool. On this basis, a privacy model hybrid recommendation algorithm for user satisfaction is formed. The algorithm includes a forward recommendation process and a reverse recommendation process, which can respectively perform data anonymization processing for users with different anonymization technical knowledge backgrounds. The privacy model hybrid recommendation algorithm for user satisfaction described in this paper is suitable for a wider population, providing a simpler, more efficient and automated solution for data anonymization, reducing data processing time and improving the quality of anonymized data, which enhances data protection capabilities.

An Experimental Study on Pool Boiling Heat Transfer Enhancement of Structured Tubes Having Three-Dimensional Roughness (삼차원 조도를 가진 성형가공관의 R-134a 풀비등 열전달 촉진에 관한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.5
    • /
    • pp.195-201
    • /
    • 2016
  • Enhanced tubes are widely used in air-conditioning and process industries. Structural tubes having three-dimensional roughness are well known to be able to significantly enhance pool boiling heat transfer of refrigerants. In this study, five structural enhanced tubes having different fin density, fin height, and fin gap width were tested using R-134a. Results showed that the heat transfer coefficient was increased with increased fin density. Within test range, the effect of fin height on pool boiling heat transfer coefficient was insignificant. The heat transfer coefficients of the optimum configuration (2047 fpm, 0.21 mm gap width) tube were lower than those of other commercial enhanced tubes. This might be due to the larger fin gap width of the present enhanced tube.

Stratified steam explosion energetics

  • Jo, HangJin;Wang, Jun;Corradini, Michael
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.95-103
    • /
    • 2019
  • Vapor explosions can be classified in terms of modes of contact between the hot molten fuel and the coolant, since different contact modes may affect fuel-coolant mixing and subsequent vapor explosion energetics. It is generally accepted that most vapor explosion phenomena fall into three different modes of contact; fuel pouring into coolant, coolant injection into fuel and stratified fuel-coolant layers. In this study, we review previous stratified steam explosion experiments as well as recent experiments performed at the KTH in Sweden. While experiments with prototypic reactor materials are minimal, we do note that generally the energetics is limited for the stratified mode of contact. When the fuel mass involved in a steam explosion in a stratified geometry is compared to a pool geometry based on geometrical aspects, one can conclude that there is a very limited set of conditions (when melt jet diameter is small) under which a steam explosion is more energetic in a stratified geometry. However, under these limited conditions the absolute energetic explosion output would still be small because the total fuel mass involved would be limited.

A Study on Design and Performance of a Heat pipe for the application to Solar collector (태양열 집열기용 열파이프의 구조와 작동 특성에 관한 연구)

  • 임광빈;김철주;박이동;황영규;강환국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.70-78
    • /
    • 1993
  • Heat pipes, applied to flat plate solar collectors, have a long and slender configuration with relatively low heat flux on the evaporator. Such a heat pipe has a tendency to build-up a liquid pool at the lower half of evaporator zone, and at this pool occurs such complicated phenomena of evaporation and fluid dynamics as superheat, sudden generation of bubble, its likely explosive growth process and flooding etc. In the present study, we tried to solve those problems by means of adjusting the two principle design parameters, liquid fill charge and wick length, using 4 heat pipes and 3 thermosyphons, with different values of parameter respectively. The corresponding results can be summarized as followings, - The thermal conductance of heat pipes was largely improved by el eliminating wick from adiabatic and condenser zone. - But on evaporator zone wick is inevitable to reduce behavior of the build -up of liquid pool , where arise diverse internal complex phenomena. - The liquid fill charge should have to be increased by 10∼20% more than the quantity to saturate the wick.

  • PDF

Pressure Wave Propagation in the Discharge Piping with Water Pool

  • Bang Young S.;Seul Kwang W.;Kim In-Goo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.285-294
    • /
    • 2004
  • Pressure wave propagation in the discharge piping with a sparger submerged in a water pool, following the opening of a safety relief valve, is analyzed. To predict the pressure transient behavior, a RELAP5/MOD3 code is used. The applicability of the RELAP5 code and the adequacy of the present modeling scheme are confirmed by simulating the applicable experiment on a water hammer with voiding. As a base case, the modeling scheme was used to calculate the wave propagation inside a vertical pipe with sparger holes and submerged within a water pool. In addition, the effects on wave propagation of geometric factors, such as the loss coefficient, the pipe configuration, and the subdivision of sparger pipe, are investigated. The effects of inflow conditions, such as water slug inflow and the slow opening of a safety relief valve are also examined.

A Comparative Study of SERVQUAL and SERVPERF in Measuring the Pallet Pool Service Quality (파렛트 Pool 서비스품질 측정에 있어서 SERVQUAL과 SERVPERF 모형비교 연구)

  • Oh, Sun-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.157-167
    • /
    • 2011
  • Currently, interest on physical distribution is increasing due to burden of oil cost increases as oil price rises day by day. As interest grows, there are number of studies have been conducting on saving the cost of distribution. On the other hand, number of study on service of distribution is insufficient. Actually, subject of service of physical distribution have been studied by number of survey organizations, research organizations and mass media. Although, configuration for each organization is different from each other and it is hard to measure objective satisfactory factor of customers. This means needs for constructing standardized measuring tool as well as research on measuring service quality of distribution is not active. Therefore, this research is to compare and analyze compatibility of service quality measuring using SERVQUAL and SERVPERF and trying to clarify differences affected by importance service quality by each level to actual service quality. Also, this research is to make basic and standardized measuring model to improve quality of physical distribution especially using analysis of service quality and customer satisfaction of pallet pool service which contributes rationalization of distribution and reduce the cost by standardizing specification and size of pallet, allowing sharing of pallet. To conduct this research, case study of a company A is used where it is in a pallet pool business. Using this example, the goal is to give help on pallet pool business a strategic exercise if the business by point out major factors that affect customer satisfaction by collecting customer assessment along with examination of SERVQUAL and SERVPERF in measuring service quality if pallet pool service.

Experimental Evaluation Method for Performance Analysis in Web Application Services (웹 응용 서비스에서 성능 분석을 위한 실험적인 평가 기법)

  • Kim, Namyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • The performance of a web application is an essential issue to provide high quality of the services in interactive web environments. On a sudden increase in traffic in a very short span of time, the servers became CPU starved and would become unresponsive. This would lead to a bad experience for the clients of web service. This paper deals with the effects of two configurable software settings of J2EE application servers: the maximum size of the thread pool and the maximum size of database connection pool. In order to figure out the optimum configuration value, this paper builds experimental evaluation method for web performance analysis. Finally, a case study related with the proper experimental method is presented with performance result.

Comparisons of 2-D and 3-D IVR experiments for oxide layer in the three-layer configuration

  • Bae, Ji-Won;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2499-2510
    • /
    • 2020
  • We performed 3-D (3-dimensional) IVR (In-Vessel Retention) natural convection experiments simulating the oxide layer in the three-layer configuration, varying the aspect ratio (H/R). Mass transfer experiment was conducted based on the analogy to achieve high RaH's of 1.99 × 1012-6.90 × 1013 with compact facilities. Comparisons with 2-D (2-dimensional) experiments revealed different local heat transfer characteristics on upper and lower boundaries of the oxide layer depending on the H/R. For the 3-D shallow oxide layer, the multi-cell flow patterns appeared and the number of cells was considerably increased with the H/R decreases, which differs with the 2-D experiments that the number of cells was independent on H/R. Thus, the enhancement of the downward heat transfer and the mitigation of the focusing effect were more noticeable in the 3-D experiments.