• Title/Summary/Keyword: Pool Temperature

Search Result 351, Processing Time 0.03 seconds

A Study of Marketing Strategies according to the Criteria of Users' Choice in Pallet Pool Services : Focused on Mettroporitan Seoul Area Warehouse Companies (파렛트 풀 서비스의 효익세분화에 따른 마케팅 전략에 관한 연구 - 수도권 창고업체들을 중심으로 -)

  • Choi, Se-Kyung;Park, Mu-Il;Lee, Kang-Dae
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.3
    • /
    • pp.1-20
    • /
    • 2009
  • A survey to pallet users was conducted in an aspect of the efficiency and benefit. The questionnaire identified the preference about the main variables such as price, size, conformity, material, which are the criteria of the users' choice. staffs in the capital region was selected as respondents and Cluster Analysis and Simulations was carried out with Conjoint Analysis. The result shows that the variables of material and conformity between facilities and products were more important than the variable of size. The respondents prefer the pallets with a various range of products because warehouses should keep a range of products under various condition of temperature. In accordance, the companies that provide a pallet pool service should set up individual marketing strategy by a type of customers so as to maximize the competitiveness in domestic or international markets. Furthermore, supplying standardized pallets should be consistent with the standardization not for individual logistics units, but for whole logistic systems. To achieve this, it requires the compatibility amongst a range of logistics activity participants by their characteristics.

  • PDF

Study on the Oxidation Treatment of Nanoparticles for the Critical Heat Flux (임계열유속 향상을 위한 나노물질의 산화처리에 대한 연구)

  • Kim, Woo-Joong;Jeon, Yong-Han;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.39-49
    • /
    • 2017
  • Pool boiling, one of the key thermal-hydraulics phenomena, has been widely studied for improving heat transfer efficiencies and safety of nuclear power plants, refrigerating systems, solar-collector heat pipes, and other facilities and equipments. In the present study, the critical heat flux (CHF) and heat-transfer coefficients were tested under the pool-boiling state using graphene M-5 and M-15 nanofluids as well as oxidized graphene M-5 nanofluid. The results showed that the highest CHF increase for both graphene M-5 and M-15 was at the 0.01% volume fraction and, moreover, that the CHF-increase ratio for small-diameter graphene M-5 was higher than that for large-diameter graphene M-15. Also at the 0.01% volume fraction, the oxidized graphene M-5 nanofluid showed a 41.82%-higher CHF-increase ratio and a 26.7%-higher heat-transfer coefficient relative to the same nanofluid without oxidation treatment at the excess temperature where the CHF of distilled water occurs.

A Study of Smoke Movement in Tunnel Fire with Natural Ventilation (자연 배기 터널에서의 연기 거동에 관한 연구)

  • Kim, Sung-Chan;Lee, Sung-Ryong;Kim, Choong-Ik;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.976-982
    • /
    • 2002
  • In this study, smoke movement in tunnel fire with natural ventilation shaft has been investigated with various size of fire source. Gasoline pool fire with different size of diameter - 73mm, 100mm, 125mm and 154mm - was used to describe fire source. Experimental data is obtained with 1/20 model tunnel test and its results are compared with numerical results. The computation were carried out using FDS 1.0 which is a field model of fire-driven now. Temperature profiles between measured and predicted data are compared along ceiling and near the ventilation shaft. Both results are in good agreement with each other. In order to evaluating a safe egress time in tunnel fire, horizontal smoke front velocity was measured in model tunnel fire tests and those are compared with numerical results. According to the presence or absence of natural ventilation shaft, ventilation effect are estimated quantitatively. Finally, this paper shows that computational fluid dynamics(CFD) is applicable to predict fire-induced flow in tunnel.

DEVELOPMENT OF REACTOR POWER CONTROL LOGIC FOR THE POWER MANEUVERING OF KALIMER-600

  • Seong, Seung-Hwan;Kang, Han-Ok;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.329-338
    • /
    • 2010
  • We developed an achievable control logic for the reactor power level during a power maneuvering event and set up some constraints for the control of the reactor power in a conceptual sodium-cooled fast reactor (KALIMER-600) that was developed at KAERI. For simulating the dynamic behaviors of the plant, we developed a fast-running performance analysis code. Through various simulations of the power maneuvering event, we evaluated some suggested control logic for the reactor power and found an achievable control logic. The objective of the control logic is to search for the position of the control rods that would keep the average temperature of the primary pool constant and, concurrently, minimize the power deviation between the reactor and the BOP cycle during the power maneuvering. In addition, the flow rates of the primary pool and the intermediate loop should be changed according to the power level in order to not violate the constraints set up in this study. Also, we evaluated some movement speeds of the control rods and found that a fast movement of the control rods might cause the power to fluctuate during the power maneuvering event. We suggested a reasonable movement speed of the control rods for the developed control logic.

The Optimiazation of Knowledgebase for Swimming Pool Temperature Control Systems using Genetic Algorithms (Genetic 알고리즘을 이용한 풀 온도 제어 시스템의 지식베이스 최적화)

  • Kim, Seong-Hak
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.3
    • /
    • pp.319-326
    • /
    • 1994
  • Automatic control has been for the most part applied to linear systems where ti can be approximately formalized. In case that it is not definitely established the mathematical modelling to control objects, it requires manual control strategies which put under the human rule. In this paper, it constructs an FLC (Fuzzy Logic Controller) in order to turn a hand control into an automatic control in the domain of swimming pool that has been almost absolutely dependant on a skilled worker's experience. Genetic algorithms upgrade the knowledge which is acquired from human expert, using by FLC, so as to maintain knowledge in the very optimal way. It also designs an algorithm that modifies the rule base and the membership function at the same time, and ultimately will show that it can get better result than human controllers.

  • PDF

Growth Charateristics of Methane-Propane Clathrate Hydrate (메탄-프로판 하이드레이트의 성장 특성에 관한 연구)

  • Lee, Ju-Dong;Lee, Man-Sig;Kim, Young-Seok;Song, Myung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.391-394
    • /
    • 2006
  • Growth characteristics of methane-propane clathrate hydrate, growing under different undercooling conditions, was investigated. After the water within pressurized vessel was fully saturated with guest gas molecules by agitation, medium was rapidly undercooled and maintained at the constant temperature. The growth of hydrate was always Initiated with film formations at the upper bounding surface of liquid pool. The visual observation using microscope revealed detailed features of subsequent crystal nucleation, migration, growth and interference occurring within liquid pool. A number of small crystals ascended and settled at the hydrate film. When undercooling was small $({\Delta}T=3.2K)$, some of the settled crystals slowly grew into faceted columns. As the undercooling increased, the downward growth of crystals underneath the hydrate film became dendritic and occurred with greater rate and with finer arm spacing. The shapes of the floating crystals were diverse and included octahedron and triangular or hexagonal platelet When the undercooling was small, the octahedral crystals were found dominant. As the undercooling increased, the shape of the floating crystals also became dendritic. The detailed characteristics of floating crystals were reported in this study.

  • PDF

Effects of Oxygen Contents in Shielding Gas on the Properties of Ferritic Stainless Steel GTA Weld (페라이트계 스테인리스강 GTA 용접부 특성에 미치는 보호가스 중 산소의 영향)

  • Lee, Won-Bae;Uhm, Sang-Ho;Woo, In-Su
    • Journal of Welding and Joining
    • /
    • v.28 no.5
    • /
    • pp.93-98
    • /
    • 2010
  • The properties of GTA weld for ferritic stainless steel have been studied with different $O_2$ contents in Ar shielding gas at the constant welding speed. A small amount of $O_2$ (0.01~1.0%) was mixed in Ar shielding gas in order to improve the weld penetration. The fully penetrated GTA weld was acquired at 160A weld current shielded by pure Ar gas. Addition of oxygen larger than 0.1% made a full penetration at lower weld current than 160A. The small addition of $O_2$ in Ar shielding gas improved the penetration properties of GTA weld because the $O_2$ in the molten pool accelerated the flow of molten pool and changed the flow pattern from outward to inward direction. The impact energy and DBTT (Ductile- Brittle- Transition-Temperature) of the GTA weld shielded by Ar+$O_2$ (less 0.3%) was similar and the corrosion properties of GTA weld was slightly inferior to those of GTA weld shielded by pure Ar gas.

PARAMETER DEPENDENCE OF STEAM EXPLOSION LOADS AND PROPOSAL OF A SIMPLE EVALUATION METHOD

  • MORIYAMA, KIYOFUMI;PARK, HYUN SUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.907-914
    • /
    • 2015
  • The energetic steam explosion caused by contact between the high temperature molten core and water is one of the phenomena that may threaten the integrity of the containment vessel during severe accidents of light water reactors (LWRs). We examined the dependence of steam explosion loads in a typical reactor cavity geometry on selected model parameters and initial/boundary conditions by using a steam explosion simulation code, JASMINE, developed at Japan Atomic Energy Agency (JAEA). Among the parameters, we put an emphasis on the water pool depth that has significance in terms of accident mitigation strategies including cavity flooding. The results showed a strong correlation between the load and the premixed mass, defined as the mass of the molten material in low void zones (void fraction < 0.75). The jet diameter and velocity that comprise the flow rate were the primary factors to determine the premixed mass and the load. The water pool depth also showed a significant impact. The energy conversion ratio based on the enthalpy in the premixed mass was in a narrow range ~4%. Based on this observation, we proposed a simplified method for evaluation of the steam explosion load. The results showed fair agreement with JASMINE.

An Implementation of DAQ and Monitoring System for a Smart Fish Farm Using Circulation Filtration System

  • Jeon, Joo Hyeon;Lee, Na Eun;Lee, Yoon Ho;Jang, Jea Moon;Joo, Moon Gab;Yoo, Byung Hwa;Yu, Jae Do
    • Journal of Information Processing Systems
    • /
    • v.17 no.6
    • /
    • pp.1179-1190
    • /
    • 2021
  • A data acquisition and monitoring system was developed for an automated system of a smart fish farm. The fish farm is located in Jang Hang, South Korea, and was designed as circulation filtration system. Information of every aquaculture pool was automatically measured by pH sensors, dissolved oxygen sensors, and water temperature sensors and the data were stored in the database in a remoted server. Modbus protocol was used for gathering the data which were further used to optimize the pool water quality to predict the rate of growth and death of fish, and to deliver food automatically as planned by the fish farmer. By using JSON protocol, the collected data was delivered to the user's PC and mobile phone for analysis and easy monitoring. The developed monitoring system allowed the fish farmers to improve fish productivity and maximize profits.

Wind Effect on the Distribution of Daily Minimum Temperature Across a Cold Pooling Catchment (냉기호 형성 집수역의 일 최저기온 분포에 미치는 바람효과)

  • Kim, Soo-Ock;Kim, Jin-Hee;Kim, Dae-Jun;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.4
    • /
    • pp.277-282
    • /
    • 2012
  • When wind speed exceeds a certain threshold, daily minimum temperature does not drop as predicted by the geospatial model in a cold pooling catchment. A linear regression equation was derived to explain the warming effect of wind speed on daily minimum temperature by analyzing observations at a low lying location within an enclosed catchment. The equation, Y=2X+0.4 ($R^2$=0.76) where Y stands for the warming ($^{\circ}C$) and X for the mean horizontal wind speed (m/s) at 2m height, was combined to an existing model to predict daily minimum temperature across an enclosed catchment on cold pooling days. The adjusted model was applied to 3 locations submerged in a cold air pool to predict daily minimum temperature on 25 cold pooling days with the input of simulated wind speed at each location. Results showed that bias (mean error) was reduced from -1.33 to -0.37 and estimation error (RMSE) from 1.72 to 1.20, respectively, in comparison with those from the unadjusted model.