• Title/Summary/Keyword: Pond system

Search Result 219, Processing Time 0.029 seconds

Stormwater treatment using Wetland and Pond (습지와 유수지를 이용한 강우 유출수 처리)

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong;Koo, Won-Suk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.575-578
    • /
    • 2003
  • Constructed wetlands have become a popular technology for treating contaminated surface and wastewater. In this study, the field experiment to reduce nonpoint source pollution from watershed runoff during rainy day using wetland and pond. TSS and T-N removal rate of wetland-pond system and pond-wetland system was 91% and 73%, 94% and 70%, respectively and values were same range. $BOD_5$ and T-P removal rate of pond-wetland system (38% and 78%) was higher than wetland-pond system (27% and 62%). overall, pond-wetland system is more useful than wetland-pond system to control NPS.

  • PDF

Pond System for Further Polishing of Constructed Wetland Effluent during Winter Season (연못을 이용한 동절기 인공습지 오수처리수의 추가 처리)

  • Yoon, Chun-Gyeong;Jeon, Ji-Hong;Kim, Min-Hee;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.139-148
    • /
    • 2002
  • Pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent from December 2000 to June 2001. The wetland system used for the experiment was highly effective to treat the sewage during the growing season, but it was less effective and its effluent was still high to discharge to the receiving water body. Therefore, the wetland effluent may need further treatment to prevent water quality degradation. Pond system could be used to hold and further polish the wetland effluent during the winter season and ots feasibility was evaluated in this study. Additional water quality improvement was apparent in the pond system during winter season, and the pond effluent could be good enough to meet the effluent water quality standards if it is properly managed. Timing of the pond effluent discharge appears to be critical for pond system management because it is a closed system and whole water quality constituents are affected by physical, chemical, and biological pond environments. Once algae started to grow in mid-April, constituents in the pond water column interact each other actively and its control becomes more complicated. Therefore, upper layer of the pond water column which is clearer than the lower layer my need be discharged in March right after ice cover melted. In the experiment, water quality of the upper water column was markedly clear in March than ant other times probably because of freezing-thawing effect. The remaining lower water column could be further treated by natural purification as temperature goes up or diluted with better quality of wetland effluent for appropriate water uses. This study demonstrated the feasibility of pond system for subsequent management of wetland effluent during the winter season, however, more study is needed for field application.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Waste Water Treatment Using Constructed Wetland and Pond System (인공습지와 연못시스템을 이용한 오수처리)

  • Kim, Min-Hee;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.470-474
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the waste water treatment using constructed wetland and pond system. The effluent of the wetland system in winter often exceeded effluent water quality standards for sewage treatment plant, therefore, pond system could be applied to additional system. As a result, removal rate of $BOD_{5}$, SS was 84.4%, 81.5% and effluent concentration was 4.6mg/L and 5.0mg/L respectively, when surface water of pond system was discharged in March. So we concluded that pond system stored wetland effluent in winter and discharged surface water of pond system in March, so met water quality standard.

  • PDF

Treatment Efficiency of a Pond-Wetland System for the Water Quality Conservation of Estuarine Lake (담수호 수자원보전을 위한 수질정화 연못-습지 시스템의 초기처리수준)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.4
    • /
    • pp.64-71
    • /
    • 2001
  • Treatment efficiency was examined of a pond-wetland system constructed for water quality conservation of Koheung Estuarine Lake over one year after its establishment in July 2000. The system is composed of primary and secondary ponds in series and six wetland cells in parallel. Cattails (Typha angustiflora) were planted in three wetland cells and common reeds (Phragmites australis) in three other cells. Water pumped from Sinyang Stream flowing into the Lake was funneled into primary pond whose effluent was discharged into secondary pond by gravity flow. Effluent from secondary pond was distributed into each wetland cell. SS, $BOD_5$, T-N, and T-P concentrations in influent to primary pond, and effluent from primary pond, secondary pond, and three wetland cells planted with cattails were analyzed for about one year from August 2000 to August 2001. The removal rates at primary pond for SS, $BOD_5$, T-N and T-P were 29%, 30%, 15%, and 36%, respectively. The abatement rates at secondary pond for SS, $BOD_5$, T-N and T-P were 38%, 40%, 30%, and 47%, respectively. The reduction rates measured at three cattail-planted wetland cells for SS, $BOD_5$, T-N and T-P were 54%, 57%, 60%, and 68%, respectively. Considering early stage of the pond-wetland system and inclusion of winter during the research period, its treatment efficiency was rather good. Cattails had not yet grown to dense stands due to initial establishment period, which resulted in slightly lower treatment efficiencies of wetland cells for these pollutants, compared with those of ponds.

  • PDF

A Case Study on Development of Stormwater Retention and Infiltration Pond System (우수저류 및 침투연못 시스템개발 사례연구 - 우수 저류 및 침투 효과를 중심으로 -)

  • Lee, Jae Chul;Yoon, Yeo Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.52-61
    • /
    • 2003
  • This study was carried out to analyze the effects of stormwater retention and infiltration pond on reduction of flood peak and volume in a experimentally developed ecological pond. The experimental site has 542$m^2$ watershed area, 1,310mm yearly-averaged rainfall. And the area of the retention pond is 60$m^2$, the maximum water depth is 0.5m, the maximum and average storage is 15$m^3$and 9.3$m^3$d. And the area of infiltration pond is 58$m^2$, and the water depth varies 0.2m~0.5m. The monitoring system consists of one rainfall gage, one Parshall flume and acoustic water level gage, two rectangular weirs and acoustic water level gage for discharge gaging, and one data recording unit. Data from ten storm events in total, three storm events in year 2000 and seven storm events in year 2001, were collected. From the data the evaporation rate was achieved with the water balance equation, and the result shows 5.0mm/day in average. The result from the analysis of the effects on reduction of flood peak and volume, is that 14% reduction of flood volume and 15% reduction of flood peak in retention pond and 49% reduction of flood volume in infiltration pond.

Sewage Treatment Using Natural Systems and Effluent Reuse for Crop Irrigation in Small Communities

  • Ham, Jong-Hwa;Yoon, Chun-G.;Jeon, Ji-Hong;Hwang, Ha-Sun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.70-82
    • /
    • 2003
  • A pilot study was performed from July 1998 to December 2002, including winter performance, to examine seasonal performance of a constructed wetland and subsequent pond system for treatment of sewage in small communities of Korea. Pond was operated as a intermittent-discharge pond during winter period, and continuous flow system during growing season; its effects was evaluated from December 2001 to April 2003. The subsurface flow (SSF) wetland was satisfactory for treating sewage with good removal efficiency even during the winter period. The wetland effluent concentrations of $BOD_5$ and TSS were often higher in winter than in the growing season, but this was explained by the higher loading rates, rather than lower removal efficiency. The relatively poor-quality wetland effluent was further polished during winter in the pond. The upper layer of the pond water column became remarkably clear immediately after ice melt. In the growing season, ponds could be operated as a continuous flow system to remove nutrients and pathogens, and the effluent of pond could be reused as a supplemental irrigation water without risk of infection by sewage-borne pathogens as well as causing adverse effect on growth and yield. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the intermittent-discharge pond was found to be effective for further polishing if necessary. Therefore, the combination of a wetland and subsequent pond system and reuse of effluent as crop irrigation water is recommended as a practical alternative to treat sewage in Korean small communities, and partial discharge of pond water in March is suggested.

A Study on the Removal of TNT(2,4,6-trinitrotoluene) using Marsh and Pond Type Microcosm Wetland Systems (Marsh와 Pond 형태의 Microcosm 습지 시스템을 이용한 TNT(2,4,6-trinitrotoluene)의 분해 연구)

  • Choi, Jong-Kyu;Kim, Se-Kyung;Kang, Ho-Jeong;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.198-205
    • /
    • 2005
  • This study was carried out to investigate the removal of TNT (2,4,6-trinitrotoluene) in the batch and continuous type microcosm systems consisting of marsh and pond. First, the batch reactor study showed that TNT (10 mg/L) was completely removed in the marsh and pond system within 20 days. The major reductive metabolites of TNT include 4-amino-2,6-dinitrotoluene (4-ADNT), 2-amino-4,6-dinitrotoluene (2-ADNT), 2,4-diamino-6-nitrotoluene (2,4-DANT), and 2,6-diamino-4-nitrotoluene (2,6-DANT). These metabolites concentration also decreased during further treatment. The continuous reactor systems combining marsh and pond indicated the similar pattern of TNT degadation and the metabolites production. Among the continuous reactor combinations, marsh-pond system showed more stable TNT removal and metabolites production. The toxicity of the effluent from the continuous system was examined by Microtox Assay using Vibrio fischeri. The result showed that the effluent toxicity was reduced below toxicity endpoint ($EC_{50}$) after continuous marsh pond system, indicating that metabolites of TNT are less toxic than TNT itself. Based on the results, TNT contaminated wastewater can be efficiently treated using marsh and pond wetland systems.

Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse (자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

A Study on Obtaining Waters to Restore the Water-ecosystem of Deokjin Pond in Jeonju: New Paradigm for Restoration of Urban Reservoirs (전주시 덕진연못의 수생태 복원을 위한 용수확보방안 연구: 도시 저수지 복원의 새로운 패러다임)

  • Choi, Seung-Hyun;Kim, Seok-Hwi;Lee, Jin Won;Kim, Kangjoo;Oh, Chang Whan
    • Economic and Environmental Geology
    • /
    • v.48 no.6
    • /
    • pp.467-475
    • /
    • 2015
  • The Deokjin Pond is one of the places representing Jeonju City's history but has the poor water quality. The pond has a storage of $88,741m^3$ and a drainage area of $3.77km^2$. It has been maintained only by the groundwater pumped from the upstream wells and the direct rainfalls on the water surface since the old streams replenishing the pond were turned into a part of the sewer system due to indiscreet urbanization. The lack of replenishing water as well as the organic-rich bottom sediment were suggested as two main causes deteriorating the water-ecosystem. In this study, possible measures obtaining waters for restoration of Deokjin Pond ecosystem are discussed. It is estimated that the present pond can be replenished about 32 times a year by the runoff when the drainage system in the watershed is recovered to a state before urbanization. To support this, the drainage system is compared with that of nearby Osong Pond, which shows relatively better water-ecosystem. Even though Osong Pond has a drainage area one-seventh of that of Deokjin Pond, its storage is more than the half of it. It is because its watershed has a near natural drainage system where the rain mostly infiltrates into soil and slowly discharges into the pond. Therefore, it is believed that the low impact development (LID), which is known as a technique restoring the water circulating system to a condition before development, would be helpful in obtaining waters required for Deokjin Pond ecosystem management.