• Title/Summary/Keyword: Polytetrafluoroethylene (PTFE)

Search Result 191, Processing Time 0.026 seconds

Separation Characteristics of Oxygen Isotopes with Hydrophobic PTFE Membranes (소수성 PTFE 막의 산소동위원소 분리특성)

  • 김재우;박상언;김택수;정도영;고광훈;박경배
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.154-161
    • /
    • 2003
  • We measured the permeation characteristics of water with the hydrophobic PTFE membranes dependent on water temperature to confirm the separation of oxygen isotopes using Air Gap Membrane Distillation (AGMD) and Vacuum Enhanced Membrane Distillation (VEMD). Isotopic concentrations of $H_2^{16}O$ and $H_2^{18}O$ of the permeated water vapor were measured by Diode Laser Absorption Spectroscopy. Concentrations of the heavy oxygen isotopes in the permeated water vapor were decreased. Isotope separation coefficients for the hydrophobic PTFE membranes were 1.004∼1.01 depending on the experimental conditions. We observed the effects of air in membrane pores on the oxygen isotope separation. Isotope separation coefficients for the hydrophobic PTFE membranes without air in pores are higher than those for the membrane with air in pores.

THE EFFECTS OF POLYTETRAFLUOROETHYLENE MEMBRANE AND MILLIPORE FILTER COMBINED WITH FIBRIN ON THE REGENERATION OF PERIODONTIUM IN DOGS (Polytetrafluoroethylene membrane 및 millipore filter를 섬유소와 병용사용시 성견 치주조직 재생에 미치는 영향)

  • Joo, Sang-Don;Park, Jae-Wan;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.577-594
    • /
    • 1993
  • The ultimate goal of periodontal therapy is the regeneration of the periodontium that have been destroyed as a result of periodontal disease. This study were done in order to determine the healing status of periodontium under Polytetrafluoroethylene and millipore fillter combined with fibrin and the effect of the guided tissue regeneration procedures were performed as follows : 1) flap operation using PTFE membrane(control group) 2) flap operation using PTFE membrane which was fixed with fibrin(experimental group 1) 3) flap operation using millipore filter which was fixed with suture(experimental group II) 4) flap operation using millipore filter which was fixed with fibrin(experimental group II) After 1, 2, 4, 8, 12 weeks, dogs were sacrificed by perfusion technique and tissue block was excised including the tooth and prepared for light microscope with H-E & Masson’s trichrome staining. The result were as follows : In control and experimental group, there is no siginificant difference on epithelial cell down growth within 1st week, but more epithelial cell downgrowth in millipore or millipore combined with fibrin group. In this experiment, there were no significant difference in new cementum and alveolar bone formation whether PTFE membrane was fixed with suture or fibrin. In control and each experimental group, bone maturation appeared in 4 weeks, bone width increased bucco-lingually in control and experimental 1 group especially. Both control group and experimental group showed mild mew cementum formation on root surface and irregular arrangement of collagen fiber at 4 weeks, that showed obvious increased cementum formation at 8 weeks, and that was observed the functional arrangement of collagen fiber between new cementum and new alveolar bone at 12 weeks.

  • PDF

Comparison of Saphenous Vein and PTFE Grafts for Above the Knee Femoropopliteal Bypass Grafting (슬상부 대퇴동맥-슬와동맥 우회이식술에서 복재정맥과 PTFE 이식편의 비교)

  • Kim, Han-Yong;Kim, Jong-Seok;Kim, Myoung-Young;Hwang, Sang-Won;Yoo, Byung-Ha
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • Background: Femoropopliteal artery bypss grafting is an effective form of treatment for infrainguinal artery occlusive disease in those patients who have either intermittent claudication or resting critical ischemia. The objective of this analysis was to evaluate the long-term patency of a femoropopliteal bypass graft that is classified as an above-the-knee saphenous vein graft or an above-the-knee PTFE (polytetrafluoroethylene) graft. Material and Method:From January 1998 to February 2005, 103 above-the-knee femoro-popliteal bypasses were performed on 87 patients. There were 74 male and 13 female patients with a mean age of $65.7{\pm}9.69$ (range: 31~82). The surgical indications were intermittent claudication in 65 cases (74.7%), foot ulceration in 2 cases (2.3%), foot necrosis in 10 ases (11.5%) and toe necrosis in 10 cases (11.5%). For the bypass graft, a reversed saphenous vein was used in 31 limbs and a polytetrafluoroethylene (PTFE) prosthesis was used in 72 limbs (6 mm: 27 limbs, 8 mm: 45 limbs). The perioperative risk factors were diabetes mellitus in 33 cases (37.9%), hypertension in 47 cases (54.0%), a history of ischemic heart disease in 13 cases (14.9%) and smoking in 72 cases (82.8%). Result:There were three perioperative deaths (3.4%) and seven late deaths (8.3%). Major leg amputation was necessary in 12 patients (13.8%) during the entire course of the study. The primary patency rate at 5 years for the vein grafts, the 8 mm-PTFE grafts and the 6 mm-PTFE grafts were 84.7%, 77.4% and 74.2%, respectively and the overall primary patency rate was 78.7%, and there were no significant statistical differences among the graft groups. By using multivariate analysis, the number of patent tibial arteries was determined to be a significant factor that influenced the primary graft patency rate (p<0.005), but risk factors such as diabetes mellitus, ischemic heart disease, smoking and age had no statistically significant affect on the primary graft patency rates. Conclusion: The great saphenous vein is considered the most durable conduit for infrainguinal revascularization, but the overall results of this study show that saphenous vein and PTFE grafts have comparable patency rates when used above the knee in patients with claudication or critical ischemia. The use of PTFE above the knee is a reasonable alternative for a femoro-poplitael bypass and it is associated with acceptable long term patency rates.

Cord-like Atresia of the Abdominal Aorta Due to Takayasu Arteritis in Middle Aged Woman - A case Report - (중년 여자 환자에서 Takayasu 동맥염에 의한 복부 대동맥의 삭양 폐쇄 - 수술치험 1례-)

  • 이봉근;조성래;조봉균;이재화;조영덕
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.870-874
    • /
    • 2001
  • Takayasu arteritis is a chronic non-specific inflammatory arteriopathy that involves primarily the first branches of aortic arch but may also affect the aorta and any of its primary branches. A characteristic trait of the disease is that most of the patients are young females of mainly Asian and South American origin. Recently, we experienced a rare case of Takayasu arteritis which showed a cord-like atresia of abdominal aorta just below renal arteries in 52-year-old woman. We performed a side to side bypass graft from descending thoracic aorta to abdominal aorta just above the aortic bifurcation with a 18mm PTFE(polytetrafluoroethylene) vascular graft. The postoperative course was uneventful. .

  • PDF

Fabrication of CMC+PTFE Electrode and it's Electrochemical Performances (CMC+PTFE 혼합바인더 전극의 제조 및 전기화학적 특성)

  • Kim, Ick-Jun;Lee, Sun-Young;Moon, Seong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1248-1253
    • /
    • 2004
  • This work describes the effect of electrode binder on the characteristics of electric double layer capacitor Among carboxymethylcellulose (CMC), Polyvinylpyrrolidone (PVP), Polyvinyl Alcohol (PVA), and Polyvinylidene Fluoride (PVDF), the unit cell using CMC showed good rate capability between $2.5mA/cm^2{\sim}100mA/cm^2$ current density. However, CMC as a binder is incongruent, because the electrode bound with CMC is rigid and easy to crack during a press and winding process for fabrication of capacitor. The unit cell capacitor using the electrode bound with binary binder composed of CMC and Polytetrafluoroethylene (PTFE), especially in composition CMC : PTFE : 60 : 40 wt.%, has exhibited the better mechanical properties than those of the unit cell with CMC. On the other hand, it was also noted that the mechanical properties of CMC+PTFE electrode, coated on underlayer composed of CMC and carbon black, were much improved the binding force.

  • PDF

Micro/nano Tribological and Water Wetting Characteristics of Ion Beam Treated PTFE Surfaces

  • Yoon, Eui-Sung;Oh, Hyun-Jin;Yang, Seung-Ho;Kong, Hosung
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.12-16
    • /
    • 2002
  • Micro/nano tribological and water wetting characteristics of ion beam treated PTFE (polytetrafluoroethylene) surfaces were experimentally studied. The ion beam treatment was performed with a hollow cathode ion gun at different argon ion dose conditions in a vacuum chamber to modify the topography of PTFE surface. Micro/nano tribological characteristics, water wetting angles and roughness were measured with a micro tribe tester, SPM (scanning probe microscope), contact anglemeter and profilometer, respectively. Results showed that surface roughness increased with the argon ion dose. Water wetting angle of the ion beam treated samples increased with the ion dose, so the surface shows an ultra-hydrophobic nature. Micro-adhesion and micro-friction depend on the wetting characteristics of the PTFE samples. However, nano-tribological characteristics showed different results. The scale effect of surface topography on tribological characteristics was discussed. Also, the water wetting characteristics of modified PTFE samples were discussed in terms of the surface topographic characteristics.

The Comparative Study On Scanning Electron Microscopic Findings Of Retrived ePTFE Membrane With Clinical Conditions (제거된 ePTFE 막의 주사전자현미경적 소견과 치주임상상태의 비교연구)

  • Park, Jeong-Min;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.133-142
    • /
    • 1996
  • Ten intrabony defects in 10 patients were treated by flap surgery including root surface debridement and placement of an expanded polytetrafluoroethylene(ePTFE) membrane. The membranes were removed after 4-6 weeks. This study was performed to examine the retrived ePTFE membrane by scanning electron microscopy(SEM) for bacterial contamination and adherent connective tissue elements, and to compare it with clinical conditions. The cervical portion of the membrane, which in most cases had become partially exposed to the oral cavity, had a bacterial deposit. Small bacterial colonies and a scatter of single cells in some instances extended into the apical portion of the membrane. Fibroblast-like cells, erythrocytes and fibrous structures were seen in the apical portion of the membrane. Outer surface of membrane tends to more bacterial contamination than inner surface(p<0.01), and upper portions more than lower portions(P<0.01). Comparison of ultrastructural findings and clinical conditions revealed that extent of bacterial contamination of the membrane correlated with gingival inflammation and extent of membrane exposure, but it was not significant statistically. The results suggested that gingival inflammation and membrane exposure affect periodontal regeneration by the use of ePTFE membrane.

  • PDF