• 제목/요약/키워드: Polytetrafluoroethylene (PTFE)

검색결과 190건 처리시간 0.028초

Secondary closure of an extraction socket using the double-membrane guided bone regeneration technique with immediate implant placement

  • Yun, Jeong-Ho;Jun, Choong-Man;Oh, Nam-Sik
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.253-258
    • /
    • 2011
  • Purpose: Immediate implantation presents challenges regarding site healing, osseointegration, and obtaining complete soft-tissue coverage of the extraction socket, especially in the posterior area. This last issue is addressed herein using the double-membrane (collagen membrane+high-density polytetrafluoroethylene [dPTFE] membrane) technique in two clinical cases of posterior immediate implant placement. Methods: An implant was placed immediately after atraumatically extracting the maxillary posterior tooth. The gap between the coronal portion of the fixture and the adjacent bony walls was filled with allograft material. In addition, a collagen membrane (lower) and dPTFE membrane (upper) were placed in a layer-by-layer manner to enable the closure of the extraction socket without a primary flap closure, thus facilitating the preservation of keratinized mucosa. The upper dPTFE membrane was left exposed for 4 weeks, after which the membrane was gently removed using forceps without flap elevation. Results: There was considerable plaque deposition on the outer surface of the dPTFE membrane but not on the inner surface. Moreover, scanning electron microscopy of the removed membrane revealed only a small amount of bacteria on the inner surface of the membrane. The peri-implant tissue was favorable both clinically and radiographically after a conventional dental-implant healing period. Conclusions: Secondary closure of the extraction socket and immediate guided bone regeneration using the double-membrane technique may produce a good clinical outcome after immediate placement of a dental implant in the posterior area.

파괴된 치주조직의 재생촉진에 관한 연구 (A STUDY OF REGENERATION ENHANCEMENT OF DESTRUCTED PERIODONTAL TISSUE)

  • 한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.407-417
    • /
    • 1995
  • In order to evaluate the effect of platelet-derived growth factor(PDGF-BB) and guided tissue regeneration(GTR) technique on the regeneration of destructed periodontal tissue,intentional through-and-through furcation defects(4mm in height) were made on both mandibular 2nd and 4th premolars of 8 adult male dogs(30-40lb). Experimental group 1 was composed of the premolars that were treated by only topical application of PDGF-BB with 0.05M acetic acid without any barrier membrane. Experimental group 2 was composed of the premolars that were treated by GTR with expanded polytetrafluoroethylene membrane(ePTFE : Gore-tex periodontal material, USA). Experimental group 3 was composed of the premolars that were treated by GTR with ePTFE after topical application of PDGFBE. Control group was composed of the premolars that were treated by coronally positioned flap operation only without use of PDGF-BB and ePTFE membrane. All ePTFE membranes were carefully removed 4 weeks after regenerative surgery, and all experimental animals were sacrificed 8 weeks after regenerative surgery. The light microscopic findings were as follows ; (1) In experimental group 1, rapid new bone formation along the-root surface with multiple ankylosis and root resorption by multinucleated giant cells, and dense connective tissue in the central portion of the furcation defects were observed. (2) In experimental group 2, it was observed that the furcation defects were filled with newly formed bone, Sharpey's fibers were embedded into new cementum on root dentin of furcation fornix area, but the central portion and the area under furcation fornix were still filled with dense connective tissue. (3) In experimental group 3, the furcation defects were regenerated with newly formed dense bone and regular periodontal ligament with Sharpey's fibers embedded into newly formed cementum and bone underneath fornix area. (4) In control group, unoccupied space, apical migration of epithelium, dense infiltration of inflammatory cells in subepithelial connective tissue in relation to heavy plaque accumulation, and root resorption by inflammatory reaction were shown, but any new cementum formation on resorbed dentin surface could not be observed. The present study demonstrated that the combined therapy of PDGF-BB and GTR could enhance the regeneration of destructed periodontal tissue.

  • PDF

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

응집 및 정밀여과공정의 강화역세정시 NaOCl에 따른 PTFE막 투과능 회복과 막오염층 변화 (Permeability recovery and changes in fouling layer characteristics of PTFE membrane by enhanced backwash cleaning using NaOCl during coagulation and microfiltration)

  • 강선구;박근영;곽동근;김윤중;권지향
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.233-241
    • /
    • 2015
  • Polytetrafluoroethylene (PTFE) membrane has high resistance to chlorine, which is a great advantages in chemical cleaning to recover water flux during membrane processes in drinking water systems. A humic kaolin water with approximately 4 mg/L of DOC and 10 NTU of turbidity was prepared as a feed water. Coagulation pretreatment with or without settling was applied. The coagulation with settling showed the greatest water production. The reduced flux was effectively recovered by NaOCl cleaning, i.e., 21% recovery by 50 mg/L of NaOCl cleaning and 49% recovery by 500 mg/L NaOCl cleaning. The images of SEM and AFM analyses were corresponded to the water flux variation. However, when the floc was accumulated on the membrane surfaces, the efficiency of NaOCl cleaning was substantially limited. In addition, dynamic contact angle became greater after cleaning, which indicates changes in characteristics of fouling layer such as surface hydrophobicity. Proper cleaning technologies during enhanced backwash using NaOCl would expand application of PTFE membranes in drinking water systems.

PTFE재질의 평판형 분리막과 인제거를 위해 Alum주입을 적용한 고플럭스 MBR시스템에 관한 연구 (A Study on the high-flux MBR system using PTFE flat membrane and coagulant(Alum) for removal of phosphorus)

  • 이의종;김관엽;권진섭;김영훈;이용수;이창하;전민정;김형수;김정래;정진호
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.95-106
    • /
    • 2011
  • Even though MBR processes have many advantages such as high quality effluents, a small footprint and convenience for operation compared to conventional activated sludge processes, there are some shortcomings in terms of the cost and potential fouling incident that keeps MBR (Membrane bioreactor) processes from being widely applied. To reduce these problems, PTFE (Polytetrafluoroethylene) flat sheet membranes that have excellent permeability and durability were tested instead of PVDF (Polyvinylidene fluoride) membrane which is being used widely in water treatment. Low concentration of sodium hydroxide (NaOH) was also added into the membrane modules in order to prevent the membrane fouling as well as to provide the alkalinity. With conditions mentioned above, a pilot-scale MBR system based on the MLE (Modified Ludzack Ettinger) process was operated at flux of 40 $L/m^{2}/hr$ and over 15,000 mg/L MLSS concentration for about 8 months. And coagulant(alum) was added into the membrane tank to remove phosphorus. Although the more coagulant is added the more effectively phosphorus is removed, that can lead to fouling for a long operation(Ronseca et al.,2009). By the way there is a research that fouling grow up after stopping injection of coagulant(Holbrook, 2004). Stable operation of MBR systems was achieved without major chemical cleaning and the effluent quality was found to be good enough to comply with the treated waste water quality regulations of the Korea.

다공성 고분자 분리막의 임계투과압력 (Critical Breakthrough Pressure through Porous Polymer Membrane)

  • 이용택;전현수;안효성;이영진;송인호;이형근
    • 멤브레인
    • /
    • 제16권4호
    • /
    • pp.259-267
    • /
    • 2006
  • 다공성 폴리비닐리덴플루오라이드(PVDF, polyvinylidenefluoride) 그리고 폴리테트라플루오르에틸렌(PTFE, Polytetrafluoroethylene)에 대하여 순수한 물, $0.1M{\sim}4.0M$ NaOH 수용액, 그리고 $0.1M{\sim}3.0M\;NaHSO_3$ 수용액을 사용하여 임계투과압력을 측정하였다. 임계투과압력은 동일한 평균 기공 크기의 PVDF보다 PTFE가 크게 나타남을 관찰할 수 있었다. NaOH 수용액의 경우 NaOH의 농도 증가에 따라 임계투과압력은 감소하였으며 1.0 M 농도에서 최소값을 나타낸 후 다시 증가함을 확인하였다. 그러나 NaOH이 아닌 다른 염을 용해한 수용액인 $NaHSO_3$ 수용액의 경우 농도를 3.0 M까지 증가하여도 임계투과압력이 계속 감소함을 알 수 있었다. 이와 같은 현상을 이론적인 Cantor식으로 해석할 수 있었다.

Superhydrophobic nano-hair mimicking for water strider leg using CF4 plasma treatment on the 2-D and 3-D PTFE patterned surfaces

  • Shin, Bong-Su;Moon, Myoung-Woon;Kim, Ho-Young;Lee, Kwang-Ryeol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.365-365
    • /
    • 2010
  • Similar to the superhydrophobic surfaces of lotus leaf, water strider leg is attributed to hierarchical structure of micro pillar and nano-hair coated with low surface energy materials, by which water strider can run and even jump on the water surface. In order to mimick its leg, many effort, especially, on the fabrication of nanohairs has been made using several methods such as a capillarity-driven molding and lithography using poly(urethane acrylate)(PUA). However most of those effort was not so effective to create the similar structure due to its difficulty in the fabrication of nanoscale hairy structures with hydrophobic surface. In this study, we have selected a low surface energy polymeric material of polytetrafluoroethylene (PTFE, or Teflon) assisted with surface modification of CF4 plasma treatment followed by hydrophobic surface coating with pre-cursor of hexamethyldisiloxane (HMDSO) using a plasma enhanced chemical vapor deposition (PE-CVD). It was found that the plasma energy and duration of CF4 treatment on PTFE polymer could control the aspect ratio of nano-hairy structure, which varying with high aspect ratio of more than 20 to 1, or height of over 1000nm but width of 50nm in average. The water contact angle on pristine PTFE surface was measured as approximately $115^{\circ}$. With nanostructures by CF4 plasma treatment and hydrophobic coating of HMDSO film, we made a superhydrophobic nano-hair structure with the wetting angle of over $160^{\circ}C$. This novel fabrication method of nanohairy structures has been applied not only on 2-D flat substrate but also on 3-D substrates like wire and cylinder, which is similarly mimicked the water strider's leg.

  • PDF

Recovery of Levafix brilliant red E-4BA and Levafix brilliant red E-6BA from aqueous solution by supported liquid membrane

  • Muthuraman, G.;Sathya, M.;Soniya, M.;Elumalai, S.
    • Membrane and Water Treatment
    • /
    • 제4권4호
    • /
    • pp.277-291
    • /
    • 2013
  • The transport and recovery of Levafix brilliant red E-4BA and Levafix brilliant red E-6BA were investigated using polytetrafluoroethylene (PTFE) fiber based supported liquid membrane containing tetra butyl ammonium bromide (TBAB) in coconut oil as a carrier. The influencing parameters studied are: pH of the feed solution, concentration of dye in the feed solution, extractant concentration, and various kind of stripping agent, rate of stirring, time of transport, reusability of membrane and stability of membrane. Increase in TBAB concentration inside the membrane enhances the flux with its maximum value at $1.553{\times}10^{-4}$ M TBAB. Further increase in the concentration of TBAB leads to decreased rate of transport due to increase in viscosity of membrane liquid. The optimum conditions for dye transport are: pH of feed ($7{\pm}0.1$), $1.553{\times}10^{-4}$ M extractant concentration, 350 rpm for stirring, $4.9{\times}10^{-1}$ M potassium hydrogen phthalate as a stripping solution, the time of transport 6 h. It was noticed that flux values were increased with increasing dye concentration in the feed phase. Applying this study to textile wastewater, dyes were transported up to 98% in 6 h. This recovery technique is rewarding to environment and economic.

청색심기형환자에서 PTFE 인조혈관을 이용한 쇄골하-폐동맥 단락술의 임상적 적용과 그 결과 (Clinical Application and its Result of Modified Blalock-Taussig Shunt Using Polytetrafluoroethylene in Congenital Cyanotic Heart Disease)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.55-61
    • /
    • 1988
  • This report provides follow-up data on 116 patients with congenital cyanotic heart disease, aging 1 month to 13 years [median: 1.8 years], who underwent the modified Blalock-Taussig shunt using polytetrafluoroethylene graft at Seoul National University Hospital between September, 1984 and June, 1987. Among 116 patients complete follow-up studies were done on 95 patients. The mean preoperative arterial oxygen tension was 36 torr. Thirty-Six patients [38%] underwent operation in infancy. Conduit diameters included 4mm [15 cases], 5mm [47 cases], and 6mm [33 cases] sizes. The mean postoperative arterial oxygen tension was 52 torr [P<0.001]. The effectiveness of shunts was evaluated clinically and by shunt murmur, echocardiography and cardiac catheterization with angiography 1 to 31 months after operation. The incidence of shunt occlusion was 9.5% and the mortality was 14.8%. The actuarial patency rate was 83.1 * 6.4% and the actuarial survival rate was 82.5 * 4.5% at 30 months` follow-up for all patients. The effectiveness of the 4mm diameter conduit may be limited. Blalock-Taussig procedure is an effective alternative to the classic B-T shunt in congenital cyanotic heart disease.

  • PDF

불소수지 필름에 2-Hydroxyethyl methacrylate와 스틸렌의 방사선 그라프트 공중합 (Radiation-Induced Graft Copolymerization of 2-hydroxyethyl-methacrylate and Styrene onto Polytetrafluoroethylene)

  • 노영창;;;진준하
    • 공업화학
    • /
    • 제3권3호
    • /
    • pp.491-498
    • /
    • 1992
  • 2-hydroxyethyl methacrylate(HEMA)나 스틸렌을 단독 혹은 혼합하여 ${\gamma}-ray$를 사용한 동시조사법으로 불소수지 필름에 공중합시켰다. 단량체 농도, 조사속도, 조사량, 용매형태 및 HEMA와 스틸렌의 혼합조성비가 방사선 그라프트율에 미치는 영향을 검토하였다. HEMA 단독으로 불소수지 필름에 그라프트시킨 경우의 그라프트율은 자주 적었으나 HEMA와 styrene 혼합물의 그라프트 공중합은 좋은 수율을 나타내었다. 그라프트 용액에 황산을 첨가하면 그라프트율 상승효과가 나타났다.

  • PDF