• 제목/요약/키워드: Polytetrafluoroethylene (PTFE)

검색결과 191건 처리시간 0.027초

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

가토 두개골 결손부에서 비흡수성 차단막의 유지 기간에 따른 골조직 형성효과 (The effect of maintenance period of non-resorbable membrane on bone regeneration in rabbit calvarial defects)

  • 정민구;장현선;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.543-551
    • /
    • 2007
  • When clinicians faced with an insufficient volume of supporting bone on ideally esthetic and bio-mechanical position for dental implantation, guided bone regeneration(GBR) was indicated. Although GBR has wide application at clinic, proper time of membrane removal remains qustionable in using non-resorbable membrane, such as non-expanded polytetrafluoroethylene(PTFE), The aim of this study was to compare the effect of maintenance period of PTFE membrane on bone regeneration in rabbit calvarial defects. Eight adult New Zealand white female rabbits were used in this study. Four defects were surgically made in their calvaria. Using a trephine bur, 4 'through and through' defects were created and classified into 3 groups, which were consisted of control group(no graft), experimental group 1(autogenous bone)and experimental group 2(deproteinized bovine bone; $OCS-B^{(R)}$). The defects were covered with PTFE membrane($Cytoplast^{(R)}$). Membranes were removed after 1, 2, 4 and 8 weeks post-GBR procedure in 2 rabbits repectively, All rabbits were sacrificed after 8 week post-GBR procedure. Specimens were harvested and observed histologically. The results were as follow; 1) The use of graft material and membrane was necessary in GBR procedure. 2) When PTFE membranes were removed early, the most favorable bone regeneration was revealed in experimental group T, followed by experimental group II and control group. 3) On GBR, it is recommended that membrane should maintain for 4 weeks with autogenous graft. As well, the use of xenograft need longer maintenance period than autogenous bone. Further evaluations will be needed, such as histomorphologic research, more species and different kinds of graft materials. And on the basis of these studies, clinical researches would be required.

이온보조반응에 의한 금속과 불소계 고분자의 접착력 증진 (Adhesion improvement between metals and fluoropolymers by ion assisted reaction)

  • 한성;조준식;최성창;윤기현;고석근
    • 한국진공학회지
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2001
  • 반응성 산소 분위기에서 불소계 고분자에 1 keV 아르곤 이온을 조사하였다. 이온 조사에 의하여 발생한 free radical과 산소 기체와의 화학 반응에 의하여 표면에 -(C-O)-,-(C=O)-,-(C=O)-O-등의 친수성 작용기가 생성되었으며 PVDF에 대한 물의 접촉각은 $75^{\circ}$에서 $31^{\circ}$로 감소하였다. 그러나 이온조사량이 큰 경우 고분자 표면에 탄화 상이 형성됨으로써 접촉각은 다시 $65^{\circ}$로 증가하였다. PTFE에 대한 접촉각은 초기에 감소하였다가 표면 거칠기가 급격히 증가함에 따라 접촉각은 더욱 크게 나타났다. 이온 조사에 의하여 표면에 형성된 극성 작용기에 의해 PVDF와 Pt의 접착력은 급격히 증가하였으며 이는 산-염기 상호작용 때문이다. PTFE와 Cu의 경우, 극성 작용기와 금속간의 화학적 결합에 의하여 접착력이 크게 증가하였다.

  • PDF

자력을 이용한 마찰진자 베어링의 면진성능 (Base Isolation Performance of Friction Pendulum System using Magnetic Force)

  • 황인호;신호재;이종세
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.55-61
    • /
    • 2008
  • 면진장치 중에서 최근 많은 연구가 이루어지고 있는 마찰진자 베어링은 적절한 마찰력을 얻기 위해 PTFE(Polytetrafluoroethylene) 마찰재가 이용되고 있다. 본 연구에서는 자력의 반발력을 이용해 재료의 성질을 대체하여 면진성능을 향상 시킬 수 있는 자력을 이용한 마찰진자 베어링을 제안하였다. 제안된 시스템은 자력에 의한 반발력이 수직력을 줄여줌으로써 재료에 의한 마찰계수의 영향을 줄일 수 있음을 가정하였다. 또한 자력의 영향을 가정하기 위해서 간단한 실험을 구성해 보았으며, 자력이 작용을 할 때 마찰계수($\mu$)를 약 20%정도 줄여줄 수 있었다. 실험 결과를 적용한 수치해석을 통해 다양한 지진에 대해서 기존의 마찰진자 베어링보다 향상된 성능을 보여주었고, 특히 지진으로 인해 구조물의 파괴에 작용하는 주된 요소인 최상층의 가속도와 구조물의 상대변위를 비교함으로써 제안된 시스템이 면진장치로서의 기능을 가지고 있음을 확인하였다. 자력을 이용하여 기존의 PTFE 마찰재를 대체할 수 있는 자력을 이용한 마찰진자 베어링의 구조적 설계를 할 수 있다면 마찰진자 베어링의 문제점을 보완한 기초격리장치로서 적용될 수 있을 것으로 사료된다.

현무암 재봉사의 연속식 테프론 코팅 공정 (Continuous PTFE Coating Process on Basalt Sewing Thread)

  • 이수
    • 한국응용과학기술학회지
    • /
    • 제31권2호
    • /
    • pp.183-189
    • /
    • 2014
  • 내화성 및 내화학성이 우수한 현무암사의 표면에 회분식 방법에 의한 테프론 코팅 연구의 결과를 토대로 연속식 코팅 공정 인자를 도출하기 위한 연구를 수행하였다. 현무암사를 7,5 wt% 트리에톡시트리플루오로실란(TMTFPS)으로 연속적으로 전처리 한 후, 침투제로 0.25 wt% bis(2-ethylhexyl)sulfo succinate (DOS-Na)가 함유된 20 wt% 테프론 수분산액으로 딥 코팅한 후 2 m의 $120^{\circ}C$ 건조 챔버에서 12 m/mim의 속도로 건조한 후 2 m의 $380^{\circ}C$ 소성 챔버에서 40초간 소성하여 최종 $3.4g_f/D$의 인장 강도와 $2.3g_f/D$의 루프강도를 가지는 테프론이 코팅된 고내열 재봉사용 현무암사를 제조하였다.

Reduced Burst Release from ePTFE Grafts: A New Coating Method for Controlled Drug Release

  • Nam, Hye-Yeong;Kim, Dae-Joong;Lim, Hyun-Jung;Lee, Byung-Ha;Baek, In-Su;Park, Sang-Hun;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.422-426
    • /
    • 2008
  • Hemodialysis graft coated with paclitaxel prevents stenosis; however, large initial burst release of paclitaxel causes many negative effects such as drug toxicity and inefficient drug loss. Therefore we developed and tested a novel coating method, double dipping, to provide controlled and sustained release of paclitaxel locally. Expanded polytetrafluoroethylene (ePTFE) grafts were dipped twice into a solution of several different paclitaxel concentrations. In vitro release tests of the double dipping method showed that early burst release could be somewhat retarded and followed by sustained release for a long time. We observed the effect of paclitaxel coating by double dipping in porcine model of arterio-venous (AV) grafts between the common carotid artery and the external jugular vein. 12 weeks after constructing AV grafts, cross sections of the graft venous anastomosis were obtained and analyzed. Paclitaxel coated ePTFE grafts by double dipping were observed to prevent neointimal hyperplasia and therefore reduced stenosis of the arteriovenous hemodialysis grafts, especially at the graft venous anastomosis sites. Our results demonstrate that second dipping of ePTFE graft, which was already coated once with paclitaxel, washes off the drug on a surface of the graft and affects the ratio of paclitaxel on the surface to that of the inner space, possibly by diffusion: thus the early burst of drug can be somewhat reduced.

무기인산염 함유 이상성 인산칼슘이 외방성 수직골 형성에 미치는 영향 (The effect of micro-macroporous biphasic calcium phosphate incorporated with polyphosphate on exophytic bone regeneration)

  • 김동환;권영혁;박준봉;정종혁;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제38권2호
    • /
    • pp.179-190
    • /
    • 2008
  • Purpose: In this study, the effect of micro-macroporous biphasic calcium phosphate(MBCP) incorporated with inorganic polyphosphate for bone regeneration in the calvaria of rabbit was evaluated. Materials and Methods: The procedure of guided bone regeneration was performed with titanium reinforced expanded polytetrafluoroethylene(TR-ePTFE) membrane. Four animal groups were compared : 1) TR-ePTFE membrane for negative control group, 2) TR-ePTFE membrane filled with MBCP for positive control group, 3) TR-ePTFE membrane filled with MBCP soaked in 4% inorganic polyphosphate for experimental group I, and 4) TR-ePTFE membrane filled with MBCP soaked in 8% inorganic polyphosphate for experimental group II. Results: 1. Negative control group showed the highest new bone formation at 16 weeks. 2. Positive control group showed the smallest new bone formation compared to other groups. 3. 8% inorganic polyphosphate induced more volume of bone formation, otherwise experimental group II did not show significant difference compared to negative control group. Conclusion: These results suggest that inorganic polyphosphate has a promoting effect on bone regeneration, possibly by enhancing osteoconductivity of the carrier and by increasing osteoinductivity of the defected alveolar bone tissue.

침지형 막 분리 활성슬러지법에서 막의 재질 및 구조가 파울링에 미치는 영향 (Influence of Membrane Material and Structure on Fouling of a Submerged Membrane Bioreactor)

  • 최재훈;김형수
    • 대한환경공학회지
    • /
    • 제30권1호
    • /
    • pp.31-36
    • /
    • 2008
  • 본 연구는 도시하수 처리를 위한 침지형 막 분리 활성슬러지법(membrane bioreactor: MBR) 시스템에서 막 재질 및 구조가 파울링에 미치는 영향을 조사하기 위하여, polytetrafluoroethylene(PTFE), polycarbonate(PCTE) 및 polyester(PETE)의 정밀여과 막(기공크기: 0.1 $\mu$m)을 사용하였다. 120일의 운전기간 동안 PETE막 여과속도는 다른 막들에 비해 가장 빠른 감소경향을 보였으나, 화학세정을 할수록 점차 PCTE 및 PTFE막과 유사한 여과속도 감소경향을 보였다. PETE막의 유기물 제거율이 다른 막들에 비해 약간 높게 나타났으며, 이것은 막의 빠른 파울링 발생과 밀접한 관련이 있는 것으로 판단된다. 반응조내 슬러지 상징액 및 막 여과수에 존재하는 DOC성분을 친수성 및 소수성으로 분획한 결과, 본 연구에서는 막의 친수성/소수성이 MBR 파울링에 미치는 영향이 크지 않은 것으로 나타났다. 파울링이 발생한 막들의 각종 여과저항 값을 분석한 결과, PETE막은 비가역적 파울링에 의한 영향이 다른 막들에 비하여 컸으며, 유기물 제거율에도 긍정적인 영향을 미친 것으로 판단된다.

Surgical Correction of Left Ventricular Assist Device Outflow Graft Obstruction Caused by a Wrapped Expanded Polytetrafluoroethylene Graft: A Case Report

  • Sung Min Kim;Ilkun Park;Siwon Oh;Hyo Won Seo;Ga Hee Jeong;Jun Ho Lee;Su Ryeun Chung;Kiick Sung;Wook Sung Kim;Yang Hyun Cho
    • Journal of Chest Surgery
    • /
    • 제57권4호
    • /
    • pp.413-417
    • /
    • 2024
  • A 70-year-old man with dilated cardiomyopathy underwent left ventricular assist device (LVAD) implantation, using a HeartWare ventricular assist device, as a bridge to candidacy. After 26 months, computed tomography (CT) angiography indicated stenosis in the LVAD outflow graft; however, the patient was asymptomatic, prompting a decision to manage his condition with close monitoring. Ten months later, the patient presented with dizziness and low-flow alerts. Subsequent CT angiography revealed a critical obstruction involving the entire LVAD outflow graft. The patient underwent emergency surgery, during which an organized seroma causing the graft obstruction was found between a wrapped expanded polytetrafluoroethylene (ePTFE) graft and a Dacron outflow graft. The covering of the outflow graft was removed, along with the organized seroma. Following removal of the ePTFE wrap and decompression of the outflow graft, normal LVAD flow was reestablished. The practice of wrapping the outflow graft with synthetic material, commonly done to facilitate later redo sternotomy, may pose a risk for outflow graft obstruction.

$BaSO_{4}$ : Eu-PTFE TLD 방사선 센서의 제작과 물리적 특성 (Preparation of $BaSO_{4}$ : Eu-PTFE TLD Radiation Sensor and Its Physical Characterstics)

  • 우홍;김성환;이상윤;강희동;김도성
    • 센서학회지
    • /
    • 제1권1호
    • /
    • pp.59-66
    • /
    • 1992
  • $BaSO_{4}$ : Eu 열형광체 분말을 제작하고 이를 PTFE로 중합한 디스크형의 $BaSO_{4}$ : Eu-PTFE 고감도 TLD 방사선 센서를 제작하였다. $BaSO_{4}$ : Eu 열형광체는 $BaSO_{4}$분말과 활성체인 Eu($Eu_{2}O_{3}$) 및 두가지 용제 $NH_{4}Cl$$(NH_{4})_{2}SO_{4}$를 각각 lmol%, 6mol% 및 5mol%의 농도로 묽은 황산에 공침하여 건조시킨 후 질소분위기에서 $1000^{\circ}C$로 1시간 동안 소결하여 제작하였을 때 $X/{\gamma}$선에 대해 최대감도를 나타내었다. 그리고 $BaSO_{4}$ : Eu glow 곡선의 주 피이크의 활성화에너지와 진동수인자 및 발광차수는 각각 1.17eV, $3.6{\times}10^{11}/sec$ 및 1.25이었으며, 발광 스펙트럼의 피이크 파장은 425nm였다. 한편 $BaSO_{4}$ : Eu-PTFE TLD의 최적제작조건은 열형광체 분말의 함량은 40wt%, TLD의 두께는 $105.7mg/cm^{2}$ 중합조건은 $380^{\circ}C$, 공기중에서 2시간으로 결정하였다. 그리고 ${\gamma}$선에 대한 TL 피이크 강도의 선량의존성은 0.01-20Gy영역에서 선형적이었으며, 감쇠율은 60시간에 약 10 %였다.

  • PDF