• Title/Summary/Keyword: Polymer specimen

Search Result 343, Processing Time 0.026 seconds

Study on the Morphology Evolution of PS/HDPE Blend During Uniaxial Elongational Flow (일축신장흐름에서의 PS/HDPE Blend의 모폴로지 변화에 관한 연구)

  • Hong, Jung-Sook;Son, Jung-Wu;Lee, Seung-Jae;Ahn, Kyung-Hyun;Lee, Seung-Jong
    • Proceedings of the Korean Society of Rheology Conference
    • /
    • 2001.06a
    • /
    • pp.11-14
    • /
    • 2001
  • Our study have aimed to identify the deformation and breakup mechanism of minor phase in polymer blends under uniaxial enlongational flow. Experimentally, we measured the transient elongational viscosity of PS/HDPE blends using the uniaxial elongational rheometer at two temperatures. And we observed the evolution of blend morphology with elongation time. Morphological change was observed by quenching the specimen after deformation. If the viscosity variation of PS was compared with that of HDPE at each temperature, PS showed larger temperature dependence than HDPE. At 155$^{\circ}C$, the dispersed phase of larger size were easily affected by affine deformation. The initial spherical shape changed to flat ellipsoid at first, then flat ellipsoid to bulbous shape, and bulbous to thin thread and its satellites. But dispersed phase of smaller size showed the change from sphere to ellipsoid. At 175$^{\circ}C$, the dispersed phase were mostly deformed from spherical shape to ellipsoid. As a result, the morphological change of dispersed phase in elongational deformation is affected by chain flexibility and viscosity ratio. We need to further study to make sure the mechanism of elongation of viscoelastic polymer blends.

  • PDF

Determination of Dynamic Fracture Toughnesses for very Brittle Materials (매우 취성인 재료의 동적 파괴인성치 결정법)

  • Lee, Ouk Sub;Jun, Hyun Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.160-165
    • /
    • 1997
  • The instrumented Charpy impact test is generally used to evaluate the dynamic fracture toughnesses for varying engineering materials. However, the test is known to be difficult to evaluate the dynamic fracturetoughnesses for very brittle materials because of the small crack initiation load which may be engulfed by the inertia load of the instrumented tup. To evaluate the dynamic fracture toughnesses of very brittle materials, such as chalk or plaster,it is thus, necessary to develop a load sensitive instrumented tup. In this study, a polymer tup, which has very small Young's modulus comparing to one of the conventional steel tup, is used for the instrumented Charpy impact test, and a proper testing method to evaluate the dynamic fracture behavior of very brittle materials is developed. The results show that the developed method can measure rapidly changing loads from the moment of contact between the tup and the specimen to dynamic crack initiation of the very brittle materials.

  • PDF

Experimental Study on Shear Retrofitting of Concrete Columns Using Iron-Based Shape Memory Alloy (철계 형상기억합금을 이용한 콘크리트 기둥의 전단보강 실험연구)

  • Jung, Donghuk;Jeong, Saebyeok;Choi, Jae-Hee;Kim, Geunoh
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 2024
  • The current study investigates the seismic performance of shear-dominant RC columns retrofitted with iron-based shape memory alloy (Fe SMA). Three RC columns with insufficient transverse reinforcement were designed and fabricated for lateral cyclic loading tests. Before testing, two specimens were externally confined with carbon fiber-reinforced polymer (CFRP) sheets and self-prestressed Fe SMA strips. The test results showed that both CFRP and Fe SMA performed well in preventing severe shear failure exhibited by the unretrofitted control specimen. Furthermore, the two retrofitted specimens showed ductile flexural responses up to the drift ratios of ±8%. In terms of damage control, however, the Fe SMA confinement was superior to CFRP confinement in that the spalling of concrete was much less and that the rupture of confinement did not occur.

Effect of PET Film Treatment on Adhesive Properties Between PET Film and Conductive Paste (PET 필름과 전도성 페이스트의 접착성에 미치는 PET 필름 처리 영향)

  • Yeong Seo Hong;Youn Cheol Kim
    • Applied Chemistry for Engineering
    • /
    • v.35 no.3
    • /
    • pp.209-213
    • /
    • 2024
  • To improve the adhesion properties between the conductive paste and PET film, the PET film was chemically treated using acids and bases and physically treated through corona discharge. A paste using ethylcellulose, which is used in actual industrial manufacturing and silane-treated CNF, as a binder was manufactured and coated on PET film to compare the adhesive properties. The specimen coated with a paste containing silane-treated CNF as a binder on a corona discharge-treated PET film showed the highest level of adhesion, 5B. On the other hand, it was confirmed that when PET film was chemically treated with acid/base, there was no improvement in adhesive properties.

Experimental Study on Blast Resistance Improvement of RC Panels by FRP Retrofitting (철근콘크리트 패널의 FRP 보강에 의한 방폭 성능 향상에 관한 실험 연구)

  • Ha, Ju-Hyung;Yi, Na-Hyun;Kim, Sung-Bae;Choi, Jong-Kwon;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2010
  • Recently, FRP usage for strengthening RC structures in civil engineering has been increasing. Especially, the use of FRP to strengthen structures against blast loading is growing rapidly. To estimate FRP retrofitting effect under blast loading, blast tests with nine $1,000{\times}1,000{\times}150\;mm$ RC panel specimens, which were retrofitted with carbon fiber reinforced polymer (CFRP), Polyurea, CFRP with Poly-urea and basalt fiber reinforced polymer (BFRP) have been carried out. The applied blast load was generated by the detonation of 15.88 kg ANFO explosive charge at 1.5 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included central deflection and strains at steel, concrete, and FRP surfaces. The failure mode of each specimen was observed and compared with a control specimen. From the test results, the blast resistance of each retrofit material was determined. The test results of each retrofit material will provide the basic information for preliminary selection of retrofit material to achieve the target retrofit performance and protection level.

Development of a novel self-centering buckling-restrained brace with BFRP composite tendons

  • Zhou, Z.;He, X.T.;Wu, J.;Wang, C.L.;Meng, S.P.
    • Steel and Composite Structures
    • /
    • v.16 no.5
    • /
    • pp.491-506
    • /
    • 2014
  • Buckling-restrained braces (BRBs) have excellent hysteretic behavior while buckling-restrained braced frames (BRBFs) are susceptible to residual lateral deformations. To address this drawback, a novel self-centering (SC) BRB with Basalt fiber reinforced polymer (BFRP) composite tendons is presented in this work. The configuration and mechanics of proposed BFRP-SC-BRBs are first discussed. Then an 1840-mm-long BFRP-SC-BRB specimen is fabricated and tested to verify its hysteric and self-centering performance. The tested specimen has an expected flag-shaped hysteresis character, showing a distinct self-centering tendency. During the test, the residual deformation of the specimen is only about 0.6 mm. The gap between anchorage plates and welding ends of bracing tubes performs as expected with the maximum opening value 6 mm when brace is in compression. The OpenSEES software is employed to conduct numerical analysis. Experiment results are used to validate the modeling methodology. Then the proposed numerical model is used to evaluate the influence of initial prestress, tendon diameter and core plate thickness on the performance of BFRP-SC-BRBs. Results show that both the increase of initial prestress and tendon diameters can obviously improve the self-centering effect of BFRP-SC-BRBs. With the increase of core plate thickness, the energy dissipation is improved while the residual deformation is generated when the core plate strength exceeds initial prestress force.

Efficiency of Retarding Reflection Crack in Reinforced-and-Modified Asphalt Pavement Overlay (개질재.보강재를 이용한 덧씌우기 아스팔트 포장의 반사균열 지연 효과)

  • Kim, Kwang-Woo;Doh, Young-Soo;Lim, Sung-Bin;Rhee, Suk-Keun;Eum, Joo-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • This study was performed to evaluate performance of polymer-modified asphalt mixtures and specially designed reinforcement techniques against reflection cracking of the asphalt pavement overlay. Selected polymers were used for asphalt modification and polyester fiber, a polypropylene film (vinyl) and a grid were used for mixture reinforcement. Using the asphalt mixture with optimum asphalt content, a slab was made and cut into two pieces of specimen. A layer of grid or vinyl was placed at the bottom of specimen to strengthen the pavement layer against crack. A repeated loading was applied to the asphalt mixture specimen which is Placed on a cement concrete with a pseudo-crack. Crack propagation under repeated loading was monitored and effectiveness of the devised crack retarding techniques was evaluated. From the test results. a significant retardation of mode I crack progress was monitored from some of the modified and reinforced asphalt mixtures.

  • PDF

Analytic adherend deformation correction in the new ISO 11003-2 standard: Should it really be applied?

  • Ochsner, A.;Gegner, J.;Gracio, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.14-26
    • /
    • 2004
  • For reliable determination of mechanical characteristics of adhesively bonded joints used e.g. as input data for computer-aided design of complex components, the thick-adherend tensile-shear test according to ISO 11003-2 is the most important material testing method. Although the total displacement of the joint is measured across the polymer layer directly in the overlap zone in order to minimize the influence of the stepped adherends, the substrate deformation must be taken into account within the framework of the evaluation of the shear modulus and the maximum shear strain, at least when high-strength adhesives are applied. In the standard ISO 11003-2 version of 1993, it was prescribed to perform the substrate deformation correction by means of testing a one-piece reference specimen. The authors, however, pointed to the excessive demands on the measuring accuracy of the extensometers connected with this technique in industrial practice and alternatively proposed a numerical deformation analysis of a dummy specimen. This idea of a mathematical correction was included in the revised ISO 11003-2 version of 2001 but in the simplified form of an analytical method based on Hooke's law of elasticity for small strains. In the present work, it is shown that both calculation techniques yield considerably discordant results. As experimental assessment would require high-precision distance determination (e.g. laser extensometer), finite element analyses of the deformation behavior of the bonded joint are performed in order to estimate the accuracy of the obtained substrate deformation corrections. These simulations reveal that the numerical correction technique based on the finite element deformation modeling of the reference specimen leads to considerably more realistic results.

  • PDF

Bond Properties of GFRP Rebar in Fiber Reinforced Concrete (Engineered Cementitious Composite) (섬유보강 콘크리트(ECC)와 GFRP 보강근의 부착 특성)

  • Choi, Yun-Cheul;Park, Keum-Sung;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.809-815
    • /
    • 2011
  • An experimental investigations on the bond-slip properties of the steel and Glass Fiber Reinforced Polymer(GFRP) bars in engineered cementitious composite (ECC) with Polyvinyl Alcohol (PVA) fibers are presented. Total of 8 beam specimens prepared according to the Rilem procedures with 2% of PVA and PE fiber volume percentage and steel and GFRP reinforcements significantly changed the failure mechanism and slightly improved bond strength. The main objective of the tests was to evaluate the load versus displacement and load versus slip behaviors and the bond strength for the following parameters: concrete type (normal and fiber concrete) and bar diameter (10 and 13 mm). The study results showed that ordinary concrete and ECC specimens showed similar behavior for steel reinforced specimen. However, GFRP reinforced specimen showed different behavior that the steel specimen. The code analytical results showed more accuracy compared to the experimental results as expected in conservative code provisions. Based on the obtained results, it is safe to conclude that the new parameters need to be adopted to ensure safe usage of ECC for construction applications.

Tensile Strength of Cement Mortar using Pitch-based Carbon Fiber Derived from Oil Residues (석유피치 재활용 탄소섬유를 혼입한 모르타르의 인장 특성)

  • Rhee, Inkyu;Lee, Jun Seok;Kim, Jin Hee;Kim, Yoong Ahm;Kim, Woo
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.20-28
    • /
    • 2017
  • The direct tensile strength of the mortar specimen containing pitch-based carbon fiber was ranged between 1/27~1/22 as compared to the average compressive strength of mortar. It was found that the direct tensile strength of the mortar containing the same amount of PAN-based carbon fiber was around 1/15. While the case of the control specimen without the carbon fiber was around 1/29. One the other hands, the flexural tensile strength of the mortar containing pitch-based carbon fibers was about 1/12 as compared to the average compressive strength. In case of the mortar specimen with PAN-based carbon fiber and control mortar were 1/10 and 1/13.5, respectively. The tensile performance of the mortar with pitch-based carbon fiber was found to be intermediate between control mortar and the reinforced mortar incorporated with the PAN-based carbon fiber.