• 제목/요약/키워드: Polyester aluminum bag

검색결과 5건 처리시간 0.017초

테들러 백 샘플러의 대체 소재로서 폴리에스터 알루미늄 백에 대한 예비연구: 환원황화합물을 중심으로 (A Preliminary Study on Polyester Aluminum Bag as the Possible Substitute for Tedlar Bag Sampler in RSC Analysis)

  • 김기현;조상희
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.454-459
    • /
    • 2011
  • In this study, the recovery rate of Tedlar bag (T) sampler was investigated in comparison to polyester aluminum bag (P) sampler. To derive the comparative data sets for the relative performance between different samplers, a series of calibration experiments were performed by using 1 ppb standard of four offensive reduced sulfur compounds (RSC) odorants ($H_2S$, $CH_3SH$, DMS, and DMDS) along with $SO_2$ and $CS_2$. All the analysis was made by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server/thermal desorber (AS/TD). The measurement data were obtained by loading gaseous standards (1 ppb) at 3 injection volumes (250, 500 and 1,000 mL) at three intervals (0, 24 and 72 hrs). The recovery rates (RR) of P sampler were computed against the slope values of T sampler. According to our analysis, P sampler exhibits slightly enhanced loss relative to T, especially with light RSCs ($H_2S$ and $CH_3SH$). At day 0, RR for the two were 88 and 85%, respectively. Such reduction proceeded rather rapidly in the case of $H_2S$ through time. However, P sampler was more stable to store $SO_2$ unlike others. Despite slightly reduced recovery, P sampler appears as a good replacement of T sampler.

악취황 성분의 채취와 샘플백 내부의 시료 유실율 비교: 검량선의 기울기를 이용한 평가 (Reduced sulfur gas loss in the bag sampling procedure - Comparison by calibration slope values)

  • 김기현;최여진;안지원
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.338-343
    • /
    • 2005
  • 본 연구에서는 실온조건에서 황성분의 채취에 사용하는 두 가지 백 방식의 시료회수율을 비교 분석하였다. 이를 위해, 가스-타잇 주사기 내부에서 원표준시료를 희석하여 검량선을 작성하였다. 그리고 이에 대비하여 테들러 백이나 플리에스터 백으로 희석한 표준시료를 이용하여 검량선을 확보하였다. 가스타잇 주사기로 확보한 검량선과 백으로 확보한 검량선의 기울기를 비교하는 방식으로 백방식의 시료 손실 또는 회수율을 비교분석한 결과, 테들러 백의 경우 평균 87%의 회수율, 폴리에스터 백의 경우 평균 77% 수준의 회수율이 관측되었다. 결과적으로 백방식으로 시료를 채취할 경우, 시료의 손실이 확인되었다. 따라서 백방식의 현장시료 채취를 할 경우, 시료의 손실에 대한 가능성을 염두에 두고 이와 관련된 여러 가지 인자들을 동시에 검정하는 것이 중요하다고 결론지을 수 있다.

환원황화합물에 대한 용기채취법의 비교 연구 (Comparison of Two Experimental Approaches to Test Temporal Storability of Reduced Sulfur Compounds in Whole Sampling Method)

  • 조상희;김기현
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.306-315
    • /
    • 2012
  • In this study, storage stability of reduced sulfur compounds ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) and $SO_2$ in sampling bags was investigated in terms of two contrasting storage approaches between forward (F) and reverse (R) direction. The samples for the F method were prepared at the same time and analyzed sequentially through time. In contrast, those of reverse (R) method were prepared sequentially in advance and analyzed all at once upon the preparation of the last sample. In addition, relative performance between two different bag materials (PVF and PEA) was also assessed by using 100 ppb standard. The response factors (RF) of gaseous RSC samples were determined by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server (AS)/thermal desorber (TD) system at storage intervals of 0, 1, and 3 days. There is no statistical difference in all RSCs between two storage methods. However, the results of relative recovery indicated 2.58~12.8% differences in compound type between the two storage methods. Moreover, loss rates and storage stability of $H_2S$ and $SO_2$ were considerably affected by bag materials than any other variables. Therefore, some considerations about storage methods (or bag material types) for sulfur compounds are needed if stored by sampling bag method.

휘발성유기물(VOC) 분석을 위한 시료보관 용기의 비교 (Comparison of sample storage containers for the analysis of volatile organic compounds (VOC))

  • 김서경;김달호
    • 분석과학
    • /
    • 제35권3호
    • /
    • pp.116-123
    • /
    • 2022
  • 대기 중 휘발성유기물(VOC) 분석을 위해 가스시료 채취 용기로서 고분자 재질의 유연한 백(bag)이나 금속재질의 캐니스터 또는 유리병 등을 사용하고 있다. 본 연구에서는 가스시료 용기에 시료 채취 후 분석 시까지 단기 보관에 따른 휘발성시료의 농도 안정성을 다양한 용기에 대해 비교하였다. 시료용기로 폴리비닐플로라이드(polyvinyl fluoride, PVF), 폴리프로필렌(polypropylene, PP), 폴리에스터-알미늄(polyester aluminum, PE-Al) 재질의 폴리머백과 스테인레스 재질의 캐니스터 그리고 2종의 갈색유리병을 사용하였으며 VOC 시료로 100 nmol/mol의 벤젠, 톨루엔, 에틸벤젠, 자일렌, 스타이렌 표준가스를 사용하였다. 열탈착-가스크로마토그래프-불꽃이온화검출기(TD-GC-FID)를 사용하여 용기 종류별로 10~20일 동안 보관된 시료의 농도변화를 측정하였다. 캐니스터와 갈색병은 1주일 동안 큰 농도의 변화가 없었으며 2주까지도 처음 농도의 80 %이상 농도를 유지하였다. 폴리머재질의 모든 백(bag)형 용기의 경우는 벤젠과 톨루엔을 제외한 모든 성분이 1일 후에 처음 농도의 70 % 미만으로 큰 농도 변화를 보였다. 특히 에틸벤젠, 자일렌, 스티렌의 경우 처음 농도의 30 % 미만이 남아 매우 큰 농도 변화를 보였다.

VOC Analyzer를 이용한 목재용 도료의 휘발성유기화합물의 간이측정 (Test Method Using VOC Analyzer to Measure VOC Emission of Paints for Wood-based Panel)

  • 엄영근;김기욱;안재윤;김현중;문석중
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.65-72
    • /
    • 2007
  • VOC Analyzer는 공기 중에 포함되어 있는 VOC (휘발성 유기화합물) 중 toluene, ethyl benzene, xylene, styrene 등 4가지 방향족 탄화수소 가스 농도를 측정하는 측정 장비이다. 검출기에는 고감도 반도체 가스센서를 사용한 가스크로마토그래피방식으로써 캐리어 가스로서는 봄베공기를 사용한다. 또한, 대기 중에 포함되어 있는 다양한 가스성분을 농축하지 않고 VOC를 분리 검출하여 농도를 편리하면서도 자세하게 측정할 수 있으므로 건축자재, 페이트, 도료, 접착제 등에서 응용될 수 있다. 이러한 장점을 가진 VOC Analyzer를 이용하여 목재에 주로 사용되는 도료로부터 VOC 방사거동을 확인하였다. 실험은 시편을 밀봉하여 실험개시 후 일정시간 간격으로 48시간까지 측정하였다. 수용성 페인트와 enamel 페인트의 VOC 방산량은 lacquer와 urethane vanish에 비해 상대적으로 적었으며 4개의 샘플 중에서 lacquer의 VOC 방산량이 가장 높게 나타났다. VOC Analyzer를 이용한 측정법은 현재 사용되고 있는 VOC 측정방법 중 가장 빠르고 경제적인 기술이기 때문에 앞으로 널리 사용된 것이라 기대된다.