• 제목/요약/키워드: Pollution reduction facilities

검색결과 98건 처리시간 0.023초

주민의식과 입지특성에 따른 농촌마을 환경영향시설의 정비방향 (Improvement Plan of Environment-Impacting Facilities by Inhabitants Consciousness and Spatial Characteristics in Rural Areas)

  • 김영주;최수명
    • 농촌계획
    • /
    • 제11권4호
    • /
    • pp.99-108
    • /
    • 2005
  • In this study, thirteen villages in Chonnam province were selected as case study sites and the spatial distribution of the facilities in the villages was examined to provide basic information fur the establishment of rural plans. According to the questionnaire survey, various problem such as environmental pollution, position, scene, management etc. was brought owing to cattle shed, and dissension was more or less seen by scale of facilities, management of facilities and waste, regional factor(stock farming management condition, life style and attitude of inhabitants) and topographical factor (height, position physical aspect of a mountain, distance with water resources etc.) etc.. The facilities could be classified into 6 types based on the their spatial locations: 1) Type 1, facilities located at the waterside; 2) Type 2, facilities located at the entrance of village; 3) Type 3 facilities, scattered in the residential area: 4) Type 4 facilities, collectivized in village; 5) Type 5 facilities, adjoining village; and 6) Type 6 facilities, scattered irregularly inside and outside of village. Based on the classification, possible implementations for the reduction of environmental impacts were suggested. The results of this study could be used as an example of study on the distribution, classification, and rearrangement of environment-impacting facilities in rural areas for improvement of their roles in providing amenity resources.

수질오염총량관리제 실효성 제고를 위한 제도개선 및 추진 방향 (Improvement and Implementation to Enhance the Effectiveness of the Total Pollution Load Control System)

  • 김석규;오승영;박수영;나은혜;김용석
    • 한국물환경학회지
    • /
    • 제39권4호
    • /
    • pp.343-355
    • /
    • 2023
  • After the implementation of the total pollution load control system, the effect of improving river water quality by expanding investments in basic environmental facilities, inducing operational efficiency, and reducing the load of various pollutants was clear. However, since the implementation of the system, the management of non-point pollutants has been neglected; management focused on specific substances (biochemical oxygen demand (BOD) and total phosphorus (T-P)) and lacked specific cause analysis and action plans, failed to establish a relationship between water quality and pollution load, failed to reflect stakeholder demands for river water quality management, and failed to apply technical conditions. Therefore, to overcome the limitations raised and achieve a practical and efficient advanced total pollution system, the current system was partially improved and will continue to be improved. This study analyzed the performance and limitations of the total pollution system and introduced recent improvements and the contents that are being improved. The main contents included reducing emissions and reduction monitoring, using water quality tele-monitoring system (TMS) data and self-measurement data, adding population-inducing facilities, and adjusting regional development projects from 20 to 30 multi-family housing units, currentizing each pollutant source according to the roadmap. If the system is improved in a developmental direction and responds to various changes, it will be a more practical and effective policy.

소규모 개인하수처리시설의 MBR공정 적용에 관한 연구 (A Study on Process Improvement for Reduction of Pollution Loading Rate in Small Individual Sewage Plant)

  • 엄한기;최유현;주현종
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.323-329
    • /
    • 2016
  • In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of $50m^3/day$ or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, $BOD_5$. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.

Selection of Business Types for the Installation of Nonpoint Pollution Source Control Facilities

  • Choi, Ji-Yong;Hwang, Dae-Ho
    • Environmental Engineering Research
    • /
    • 제15권1호
    • /
    • pp.29-33
    • /
    • 2010
  • In 2004, the Korean government launched comprehensive measures for nonpoint pollution that were intended to reduce their amount by 34.3% over of those forecast by 2020. During the first and second stages of their implementation; from 2004 to 2011, nonpoint source (NPS) measures have focused on systemic improvements and project management, as well as the introduction of optimal management techniques; accordingly, reductions have been small. However, during the third stage in 2011, serious reductions will be pursued. Accordingly, the gradual expansion of sites subject to NPS measures has focused on the establishment of a basis for reduction measures in connection with model projects during the first half of the plan, with full scale enforcement due in the second half. For Korea, rather than commencing NPS management en masse, it has been more appropriate to gradate NPS management into stages tailored to the different needs of new and existing businesses, as well as to the needs of large and small-scale businesses, in consideration of their specific circumstances. This has allowed sufficient time for such businesses to become accustomed to the concept of NPS management.

법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 - (A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo -)

  • 정승원;이강준
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

지하수수질측정망 자료를 활용한 경남 오염우려지역의 지하수 수질 특성 (Groundwater Quality Characteristics of Pollution Concerned Area in Gyeongnam Using Groundwater Quality Monitoring Data)

  • 차수연;서양곤
    • 청정기술
    • /
    • 제27권2호
    • /
    • pp.174-181
    • /
    • 2021
  • 본 연구에서는 경상남도 지역의 오염감시전용측정망의 5년간(2013 ~ 2017) 자료를 이용하여 주오염원과 분기별 지하수 수질특성을 분석하였다. 주오염원은 산업단지지역, 광산·폐광산지역 및 하수처리시설로 구별하였다. 분석 항목은 현장측정 항목(수온, pH, 전기전도도, 용존산소, 산화물환원전위), 양이온 그리고 음이온이었다. 수온과 pH는 주오염원에 따라 크게 변하지 않았다. 양이온과 음이온의 평균농도의 합은 산업단지지역에서 가장 높았고, 하수처리시설 그리고 광산·폐광산지역 순이었다. 산업단지지역에서는 전기전도도의 값이 가장 높았고, 용존산소의 값이 가장 낮았다. 산업단지지역은 나트륨이온이 가장 높은 구성비를 보인 반면 하수처리시설과 광산·폐광산지역에서는 칼슘이온이 가장 높은 값을 나타내었다. 모든 주오염원에서 중탄산염의 농도가 가장 높게 나타났다. 수온, pH 그리고 양이온과 음이온의 농도는 분기마다 크게 다르지 않았다. 수질유형 중 Na-HCO3 유형이 가장 높은 비율을 차지하였으나, 외부 오염의 가능성이 높은 Na-Cl 유형도 오염감시전용측정망의 전체 자료 중 약 20%를 차지하였다.

저류지, 습지여상, 생태호안이 연계된 수처리 시스템 (Continuous Treatment System of Detention Pond, Wetland and Ecological Revetment)

  • 서대석;김봉균;박준석;손승욱;오종민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.651-651
    • /
    • 2015
  • 최근에는 그동안 추진했던 점오염원 중심의 하천수질관리에서 벗어나 비점오염원도 중요한 오염물질로 고려되어 비점오염원 저감을 위한 많은 연구가 진행되고 있는 실정이다. 하지만 기존 비점오염원 저감시설의 설치 사례를 살펴보면 각각의 요소 기술들이 조화를 이루지 못하여 하천의 경관성을 훼손시키고 오염원 차단 및 저감 효과를 상쇄시키는 경우가 대부분이기에 이를 해결할 수 있는 통합적 운전 시스템이 필요하다. 이에 본 연구에서는 기존의 비점오염원 저감시설에 대한 연구를 발전시켜 요소기술의 개별 평가가 아닌 요소 기술들의 통합적 운영에 대한 성능 평가를 실시하고자 한다. 선정된 요소기술은 비점오염원 저감 목적으로 주로 사용되는 저류지, 인공습지, 호안을 선정하여 각 요소기술별 개별 운전과 연계처리 운전을 비교 분석하여 수질정화 능력을 검토하였다.

  • PDF

흡착재를 활용한 흡착형 무시멘트 보드의 흡착 특성 (Adsorption properties of non-cement boards using adsorbent)

  • 편수정;임현웅;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2018
  • Recently, as the interest of the government and the public on energy saving has increased, the airtightness of buildings has been improved to improve the insulation performance of buildings. However, indoor air pollution due to increase of pollution source in indoor space and lack of ventilation is increasing and interest in indoor air quality is increasing. In 2003, the Ministry of Environment enacted and promulgated the Act on Indoor Air Quality Control in Multi-use Facilities. Radon is a naturally occurring radioactive inert gas with colorless, tasteless and odorless nature. The concentration is high in a room where radon can not escape. Although lononggas is naturally occurring, it is not interested in living environment, but it is easily inhaled through human body through respiration and causes lung cancer in long-term exposure. Therefore, this study intends to carry out an experiment for the reduction of radon gas, which is the first carcinogen in indoor air pollution sources.

  • PDF

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

석탄 저회-규사 필터의 입자상물질 여과 성능 실험적 평가 (Experimental Evaluation of Particulate-matter Filtration Performance of a Bottom Ash-Silica Sand Mixture)

  • 이동현;이홍경;이윤제;안재훈
    • 한국지반공학회논문집
    • /
    • 제38권6호
    • /
    • pp.41-47
    • /
    • 2022
  • 투수성 포장은 강우를 노반으로 침투시켜 지표면 유출량 감소와 수질 개선을 기대하기 위한 기술이다. 수질 개선효과의 증대를 위해 투수성 포장 내에는 필터층을 추가하기도 한다. 본 연구에서는 투수성 포장의 구성 요소인 여재 필터의 성능을 알아보기 위해 석탄 저회-규사 여재에 대한 투수성능과 입자상 물질 제거 효율을 분석하였으며, 석탄저회와 규사를 기본 재료로 하는 5개의 여재를 대상으로 하였고, 입자상 물질로는 60㎛ 이하의 입자를 사용하였다. 순수 규사 시료 혹은 순수 석탄저회 시료는 평균적으로 약 70%의 입자상 물질 제거효율을 보였으나, 혼합 시료의 경우 제거 효율이 약 90%로서, 비점오염 저감시설에 대한 저감율 권고치인 80%를 상회하는 것으로 나타났다. 향후 현장 검증을 통한 투수성 포장 내 여재 필터 성능에 대한 검증 후 도로 시설 혹은 독립적인 여과 장치로 사용할 수 있을 것으로 판단한다.