• Title/Summary/Keyword: Pollution characteristics

Search Result 2,582, Processing Time 0.034 seconds

Characterization of Anti-pollution Film according to the Annealing Temperature for PV Module (태양광 모듈용 내오염성 필름의 열처리 온도에 따른 특성 분석)

  • Yoo, Seung-cheol;Choi, WonSeok;Lim, Yoonsik;Kim, Junghyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.33-36
    • /
    • 2018
  • The purpose of this study is to improve the efficiency of anti-pollution film for PV module. The anti-pollution coating process was performed on a glass substrate, which is the same material as the glass substrate for the PV module. We coated the anti-pollution film on the glass substrate by spray coating. After coating process, annealing process was performed during 1 hour at $200^{\circ}C$, $300^{\circ}C$, and $400^{\circ}C$. And then we analyzed the surface characteristics according to the annealing temperature of the film. Annealing process can also improve the durability of the coated film. And then we analyzed the anti-pollution characteristics, particle size of anti-pollution film, light transmittance. The particle size of anti-pollution film was analyzed with FE-SEM. The light transmittance was analyzed with UV-Visible spectroscopy including integrating sphere.

Runoff Characteristics and Non-point Source Pollution Loads from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 강우 시 비점오염 유출특성 및 오염부하량 분석)

  • Lee, Chun-Won;Kang, Seon-Hong;Ahn, Tae-Woong;Yang, Joo-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.265-274
    • /
    • 2011
  • Nowadays, the importance of non-point source pollution treatment is being emphasized. Especially, the easy runoff characteristic of highly concentrated pollutants in the roads makes the circumstance more complicated due to impermeability of roads. When the pollutants flow into steam it could make water quality in stream worse and it also causes a bad influence in the aquatic ecosystem because the effluents of rainfall-runoff may contain indecomposable materials like oil and heavy metals. Therefore, we tried to figure out the property of non-point source pollution when it is raining and carried out an assessment for the property of runoff for non-point source pollution and EMC (Event Mean Concentrations) of the essential pollutants during this study. As the result of the study, the EMC was BOD 5.2~21.7 mg/L, COD 7.5~35.4 mg/L, TSS 71.5~466.1 mg/L, T-N 0.682~1.789 mg/L and T-P 0.174~0.378 mg/L, respectively. The decreasing rate of non-point pollutant in Chungyang-Hongsung road indicates the maximum decrease of 80% until 5 mm of rainfall based on SS concentration; by the rainy time within 20~30 minutes, the decreasing rate of SS concentration was shown as 88.0~97.6%. Therefore it was concluded that it seems to be possibly control non-point pollutants if we install equipments to treat non-point pollutants with holding capacity of 30 min. It is supposed that the result of this study could be used for non-point pollutants treatment of roads in Chungyang-Hongsung area. We also want to systematically study and consistently prepare the efficient management of runoff from non-point source pollution and pollutant loading because the characteristics of non-point source pollution runoff changes depending on different characteristics and situations of roads and rainfall.

The effect on Electrical Characteristics according to the Pollution of the Field Exposed PV Modules (Field Exposed PV모듈 표면 오염이 전기적 특성에 미치는 영향)

  • Choi, Juho-Ho;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Kim, Il-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1322-1323
    • /
    • 2011
  • This study is to analysis on electrical characteristics according to the pollution of the outdoor exposed modules. Output of module is generated locally because there are various factors of pollution on the front glass of the modules. The experiments is carried out by measuring out output of the module with MP-160 and hot spots with a IR camera. This study is to analysis on electrical characteristics according to the pollution of the outdoor exposed modules.

  • PDF

A Study on Characteristics of the Spatial location of Rural Environment Pollution Facilities (농촌마을 환경오염시설의 공간적 위치 특성에 관한 연구)

  • Choi, Soo-Myung;Cho, Eun-Jung;Kim, Young-Joo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.247-253
    • /
    • 2005
  • In this stydy, the characteristics of the spatial location based on rural environment pollution facilities which can cause environmental pollution and thus lower the value of rural amenity was analyzed. This study showed that livestock feedlot occupied the highest percentage among the facilities analyzed and the size of facilities increased with increasing distance from the residential area. In addition, the facilities showed two typical characteristics in terms of their spatial distribution; uneven and even distribution which are characterized by concentrated distribution in a certain area and by scattered distribution in a wide area, respectively. As the facilities including livestock feedlot have a great potential to cause environmental problem such as air, water, soil and noise pollution, it is necessary to develop systematic plans for the management and improvement of the facilities.

  • PDF

Study on Development of the Air Pollution Management System for Disaster Prevention of Air Pollution (대기오염 재해방지를 위한 대기오염 관리시스템 구축에 관한 연구)

  • Lim, Ik-Hyun;Hwang, Eui Jin;Ryu, Ji Hyeob
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • In this study, the air pollution management system based GIS has been developed to estimate the emission rate and air pollution modeling of air pollutants, effectively. This system is able to estimate emission rate of air pollutant and to analyze the emission characteristics with high spatial and temporal resolution. air pollution modeling. The air pollution management system was applied to Gwangyang Bay including large industry complex with a large number of emission sources. The air pollution management system was constructed using the spatial database of emission sources in Gwangyang Bay. It was found that the estimated emission rates of air pollutants is similar to the emission characteristics in Gwangyang Bay. Also, the spatial distribution of pollutants was similar to the location of emission sources. The predicted results of air pollution model was showed a good correlation coefficient (0.75) for TSP. The air pollution management system is expected to be effective tool (database system (GIS)) for the management and the control of air pollution.

  • PDF

Development of Prediction Techniques of Water Pollution Sources for the Management of Total Maximum Daily Load - Population Prediction of Pollution Sources from Human Living - (수질오염총량관리를 위한 오염원 예측기법 개발 - 생활계 오염원 인구 예측 -)

  • Park, Jundae;Park, Juhyun;Lee, Suwoong;Jeong, Donghwan;Rhew, Doughee
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.561-567
    • /
    • 2007
  • It is necessary to predict future water pollution sources in the establishment of Total Maximum Daily Load (TMDL) plan for watershed management. There are some difficulties and limits in estimating the pollution sources accurately since the prediction method is not firmly established. This study reviewed the existing methods of prediction and developed a technique characteristics. The characteristics were obtained by analyzing the change pattern of pollution sources by region and incorporated in the technique. A distinctive feature of the technique is to eliminate the influences of land use change included in the pollution source data of a region. The technique has been applied and tested. The test result showed the improvement on the prediction accuracy. A computer program was also developed for the easy application of the technique.

Study of Air Quality and Land Use Correlation using GIS (GIS의한 대기오염과 토지이용상태와의 상관성분석에 관한 연구)

  • 최병길;라영우
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.345-352
    • /
    • 2004
  • This study analyzes interrelationship with air pollution quality and land use patterns using GIS. The relationship can be obtained via three steps: (1) making out air pollution map from air pollution information of study area, (2) dividing land use patterns into residential area, commercial area, industrial area, traffic concentrated area, and non-polluted area, and (3) spatial overlaying analysis of GIS. Moreover, through analyzing air pollution quality by land use patterns, pollution sources can be identified. The results also coincide with the characteristics of conventional air pollution finding. More detailed analyses using articulated on site air pollution quality measurement databases are needed to correctly identify the pollution sources through finding interrelationship with land use patterns and air pollution Quality using GIS. The developed method can help trace the path of pollution sources and plan urban land use projects.

  • PDF

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

Pollution Characteristics and Application of River Sediment of the Western Nakdong River (서낙동강의 오염 특성과 오염 퇴적물의 활용 방안)

  • 박흥재;유수진;이봉헌;정징운;안호기;박원우
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • The pollution characteristics of water quality analysis and the heavy metal analysis of river sediment in the Western Nakdong river, and then a commercial tile using the polluted sediment was produced. The analytical results of the riverbed structure and the depth distribution in the Western Nakdong river were that Macdo Stream(site 2) was the deepest(13 ft). The analytical result of water quality showed that BOD was the highest in the Hogei Stream(site 6); COD, Syanduengchi Island(site 1);SS, Macdo Stream(site 2);T-N, Suanduengchi Island(site 1);T-P, Macdo Stream(site 2). Therefore the deeper the site was the higher the pollution concentration was. The result of heavy metal analysis of the river sediment was that Pb and Cr were the highest in Kangdong Bridge(site 9); Cd, Macdo Stream(site 2), so the deeper the site was the higher the pollution concentration was. The production of tile using the mixure of the polluted sediment and the raw material was successful, so the reuse of polluted sediment was possible.

  • PDF

Regional Characteristics of Nonpoint Source Pollutant Loads in the Upstream Watersheds of Nakdong River (낙동강 상류유역의 지역별 비점오염부하 특성)

  • Choe, Gyeong-Suk;Son, Seong-Ho
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.283-292
    • /
    • 2006
  • The characteristics of nonpoint source pollutant loads in upstream of Nakdong River were studied through analysis of pollutant loads of 10 sub-watersheds divided based on administrative district. The discharge and pollutant concentration of each sub-watershed were collected from Nakdong-River Water Research Institute and Daegu Regional Environmental office, respectively. Pollution items analysed in this study were BOD, T-N and T-P. The delivery loads of the nonpoint source pollutions of each sub-watershed were calculated after analysing the concentration of the pollution of each site. Several points were found from the results. Firstly, in general, city areas including Sangju, Andong showed higher degree of nonpoint pollution than country areas including Cheongsong, Yeongyang. The sub-watersheds located upstream side, such as Yeongju, Bonghwa, Necessarily show better water quality than the sub-watersheds located downstream side, such as Mungyeong, Uiseong. This result indicates that a given pollution condition within the watershed can be more sensitive than location factor to the level of water quality. Secondly, the delivery load and area of watershed were not necessarily correlated in the sense of water quality, while the discharge was shown to be highly correlated to the delively load of pollution. Lastly, sewage and waste caused from population and livestock, as well as landuse factor, were found to significantly contribute to the water pollution. Alternative solutions for controlling pollution source, therefore, should be provided to meet target levels of water quality in these regions.

  • PDF