• Title/Summary/Keyword: Pollutants removal

Search Result 607, Processing Time 0.026 seconds

Development of Up- and Down-flow Constructed Wetland for Advanced Wastewater Treatment in Rural Communities (소규모 오수발생지역의 고도처리시설을 위한 상.하 흐름형 인공습지 개발)

  • Kim, Hyung-Joong;Yoon, Chun-G.;Kwun, Tae-Young;Jung, Kwang-Wook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.113-124
    • /
    • 2006
  • The feasibility of the up- and down-flow constructed wetland was examined fur rural wastewater treatment in Korea. Many constructed wetland process was suffered from substrate clogging and high plant stresses because of long term operation. The up- and down-flow constructed wetland process used porous granule materials (charcoal pumice : SSR=10:20:70) for promoting intake rate of nutrient to plant, and especially flow type was designed continuously repeating from up-flow to down-flow. $BOD_5$ and SS was removed effectively by the process with the average removal rate being about 75% respectively. The wetland process was effective in treating nutrient as well as organic pollutant. Removal of TN and TP were more effective than other wetland system and mean effluent concentrations were approximately 7.5 and $0.4mg\;L^{-1}$ which satisfied the water quality standard for WWTPs. The treatment system did not experience any clogging or accumulations of pollutants and reduction of treatment efficiency during winter period because constructed polycarbonate glass structure prevented temperature drop. Considering stable performance and effective removal of pollutant in wastewater, low maintenance, and cost-effectiveness, the up- and down-flow constructed wetland was thought to be an effective and feasible alternative in rural area.

Removal of S $O_{2}$ and NO by Dry Sorbent(II) - Efficiency of Cu-Ce and Cu-7Al - (건식법에 의한 이산화황과 산화질소의 제거(II) - Cu-Ce 및 Cu-7Al의 효율 -)

  • 신창섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.288-294
    • /
    • 1993
  • Flue gas control systems for small-scale combustors must be designed to provide highly effective removal of three criteria pollutants (S $O_{2}$, N $O_{x}$ and particulate matter), and must be safe, reliable and small. These requirements make dry, regenerative clean-up process particularly attractive and this paper describes a new concept for integrated pollutant control : a filter comprised of layered, gas permeable membranes that act as an S $O_{2}$ sorbant, a N $O_{x}$ reduction catalyst and a particulate filter. A mixed metal oxide sorbent, Cu-Ce was used as a sorbent/catalyst and the activity was compared with Cu-7Al. The S $O_{2}$ removal eficiency of Cu-Ce was increased with temperature increase up to 500$^{\circ}$C and the catalytic activity for NO was higher than that of Cu-7Al. By the sulfation of Cu-Ce, the reduction activity was increased at the temperature higher than 350$^{\circ}$C. The regeneration of Cu-Ce was very fast and some amount of elemental sulfar was found.

  • PDF

Acid Gas Removal Characteristics for Syngas using Fe Oxidization Process (철 산화법을 이용한 합성가스내 산성가스 제거 특성)

  • Lee, Seung-Jong;Hwang, Sang-Yeon;Yoo, Young-Don;Yun, Yong-Seung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.804-807
    • /
    • 2007
  • The acid gas removal (AGR) system was designed and installed to remove $H_2S$ in coal syngas in the pilot-scale coal gasification system for producing chemicals like Dimethyl Ether(DME). The syngas from the coal gasification at the rate of $100{\sim120$ $Nm^3$/hr included pollutants such as fly ash. $H_2S$, COS, $NH_3$, etc. The designed temperature and pressure of the AGR system are below 50oC and 8 kg/$cm^2$. Fe-chelate was used as an absorbent. $H_2S$ was stably removed below 0.5 ppm in the AGR system when the concentration of $H_2S$ was $150{\sim}450$ ppm. The pH of Fe-chelate solution was also stably maintained between $8{\sim}9$. FeMgO absorbent was also tested to remove $H_2S$ in the lab-scale AGR system and $H_2S$ was also removed below 0.5 ppm in the initial operation.

  • PDF

Optimization of Influencing Factors on Biomass Accumulation and 5-Aminolevulinic Acid (ALA) Yield in Rhodobacter sphaeroides Wastewater Treatment

  • Liu, Shuli;Li, Xiangkun;Zhang, Guangming;Zhang, Jie
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.11
    • /
    • pp.1920-1927
    • /
    • 2015
  • This study aimed to optimize four factors affecting biomass accumulation and 5-aminolevulinic acid (ALA) yield together with pollutants removal in Rhodobacter sphaeroides wastewater treatment. Results showed that it was feasible to produce biomass and ALA in R. sphaeroides wastewater treatment. Microaerobic, 1,000-3,000 lux, and pH 7.0 were optimal conditions for the highest ALA yield of 4.5 ± 0.5 mg/g-biomass. Under these conditions, COD removal and biomass production rate were 93.3 ± 0.9% and 31.8 ± 0.5 mg/l/h, respectively. In addition, trace elements Fe2+, Mg2+, Ni2+, and Zn2+ further improved the ALA yield, COD removal, and biomass production rate. Specifically, the highest ALA yield (12.5 ± 0.6 mg/g-biomass) was achieved with Fe2+ addition.

Biosorption of Hg(II) ions from synthetic wastewater using a novel biocarbon technology

  • Singanan, Malairajan
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Mercury is a toxic pollutants present in different types of industrial effluents and is responsible for environmental pollution. Removal of Hg(II) ions from synthetic wastewater was studied using the activated biocarbon produced from the leaves of Tridax procumbens (Asteraceae). The particle size of the biocarbon (BC) is in the range of $100-120{\mu}m$. The effects of initial metal ion concentration, pH, contact time, and amount of biocarbon on the biosorption process were studied at temperature of $28{\pm}2^{\circ}C$. Batch experimental studies showed that an equilibrium time of 160 min was required for the maximum removal of Hg(II) at the optimized biocarbon dose of 2.5 g per 100 mL of synthetic wastewater. The optimum pH required for maximum removal (96.5%) of Hg(II) ions was found to be 5.5. The biosorption of metal ions onto activated biocarbon surface is probably via an ion exchange mechanism. The biocarbon can be regenerated with minimum loss. Further, it can be reused without any chemical activation. The findings of the research suggested that, the biocarbon produced from cost effective renewable resources can be utilized for the treatment of industrial wastewater.

Application of Hybrid Constructed Wetland System for Stream Water Quality Improvement (오염하천 수질개선을 위한 Hybrid형 인공습지의 적용)

  • Kim, Seung-jun;Choi, Yong-su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.209-214
    • /
    • 2006
  • The purpose of this study is to improve the stream water quality by the experimental hybrid constructed wetland system. It consisted of the water layer, sand bed planted reeds, irises and roses, gravel bed, yellow-soil media bed and a flow shifter (FS) which can reverse top and bottom flow in the middle of the wetland. The organic compounds and nitrogen removal efficiencies varied with the seasons, namely temperature change. In summer, the mean efficiencies of COD and TN in the outflow from this wetland system were 63.4 and 48.0% and shown the highest, respectively, whereas, the suspended solids and phosphorus removal efficiencies seemed to be less affected by temperature. As a result of inspecting the decreasing trend of pollutants, nitrification-denitrification in the wetland was the major removal mechanism for nitrogen, the nitrogen reduction was especially enhanced by the application of a FS in the wetland, and phosphorus reduction was mainly occurred as a consequence of adsorption of the yellow-soil media.

An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System (실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

A study of decomposition of sulfur oxides using Composite catalyst by plasma reactions (복합촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구)

  • Woo, In-Sung;Hwang, Myung-Hwan;Kim, Da-Young;Kim, KwanJoong;Kim, Sung-Tea;Park, Hwa-Young
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.655-668
    • /
    • 2013
  • In this study, a combination of the plasma discharge in the reactor by the reaction surface discharge reactor complex catalytic reactor and air pollutants, hazardous gas SOx, change in frequency, residence time, and the thickness of the electrode, the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. 20W power consumption 10kHz frequency decomposition removal rate of 99% in the decomposition of sulfur oxides removal experiment that is attached to the titanium dioxide catalyst reactor experimental results than if you had more than 5% increase. If added to methane gas was added, the removal efficiency increased decomposition, the oxygen concentration increased with increasing degradation rate in the case of adding carbon dioxide decreased.

  • PDF

Non-thermal plasma를 이용한 VOCs의 제거기술

  • Song, Yeong-Hun;Sin, Wan-Ho;Kim, Gwan-Tae;Kim, Seok-Jun;Sim, Sun-Yong;Jang, Dong-Je
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.31-36
    • /
    • 1998
  • An experimental study has been performed to characterize fundamental aspects of VOCs removal using non-thermal palsma technique. The removed VOCs in the present study are toluene ($C_6H_5CH_3$), ethene ($C_2H_4$), propene ($C_3H_6$) which are typical air pollutants generated from industry and automobile engines. The non-thermal plasma used in the present experiments has been produced in a wire-cylinder reactor with pulsed corona or a packed-bed reactor filled with ceramic bead. These differently generated non-thermal plasma have been visualized with an intensified CCD. The images of non-thermal plasma have been used for optimal design of a corona reactor used in the present study. The experimental results show that the removal efficiencies of VOCs with non-thermal plasma are dependant on the reactivity of VOCs with OH, O, and $O_3$. The results also show that the removal efficiencies of VOCs decrease significantly when VOCs are treated with NO that is also oxidized in the presence of OH, O, and $O_3$.

  • PDF

A Study on a Small-scale Wastewater Treatment System Using MBR and IPNR (MBR과 IPNR을 이용한 소규모 하수처리 시스템에 관한 연구)

  • Kim, Young-Hee;Jo, Eun-Young;Yeo, In-Seol;Park, Seung-Min;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • In the purpose of this study, we investigate the characteristics of the pilot-scale wastewater treatment system applied to BAF, MBR and IPNR as examining the removal efficiency of organic pollutants and operating factors in small decentralized wastewater treatment systems, and operating factors. For long-term operation period of more than nine months, pilot-scale plant operating results appeared very stable. This results were the removal efficiency of BOD was 80.3% above and removal efficiency of COD with an average of about 91.0%, satisfied the final effluent water quality standards. TN in the final effluents was the average concentration of 7.9 mg/L, was satisfactory water quality standards 10 mg/L of TN.