• 제목/요약/키워드: Pollutants removal

검색결과 606건 처리시간 0.028초

실험실 조건에서 레인가든의 도시 비점오염물질 제거효과 (Effects of Rain Gardens on Removal of Urban Non-point Source Pollutants under Experimental Conditions)

  • 김창수;성기준
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.676-685
    • /
    • 2012
  • As impermeable layer continues to increase with the urbanization process, direct input of nonpoint source pollutants into water bodies via stormwater has caused serious effects on the aquatic ecosystem. Potential applications of rain gardens are increasing not only as best management practices (BMP) for reducing the level of nonpoint source pollutants but also as an ecological engineering alternative for low impact development (LID). In this study, remediation performance of various planting types, such as a mixed planting system with shrubs and herbaceous plants, was assessed quantitatively to effectively manage stormwater and increase landscape applicability. The mixed planting system with Rhododendron lateritium and Zoysia japonica showed the highest removal performance of $76.9{\pm}7.6%$ and $58.4{\pm}5.0%$ for total nitrogen and $89.9{\pm}7.9%$ and $82.4{\pm}5.2%$ for total phosphorus at rainfall intensities of 2.5 mm/h and 5.0 mm/h, respectively. The mixed planting system also showed the highest removal performance for heavy metals. The results suggest that a rain garden with the mixed planting system has high potential applicability as a natural reduction system for nonpoint source pollutants in order to manage stormwater with low concentrations of pollutants and will increase water recycling in urban areas.

산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건 (Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants)

  • 백경렬;구자공
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

Electro-Oxidation in Combination with Biological Processes for Removal of Persistent Pollutants in Wastewater: A Review

  • Navarro-Franco, Javier A.;Garzon-Zuniga, Marco A.;Drogui, Patrick;Buelna, Gerardo;Gortares-Moroyoqui, Pablo;Barragan-Huerta, Blanca E.;Vigueras-Cortes, Juan M.
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.1-18
    • /
    • 2022
  • Persistent organic pollutants (POPs) and emerging pollutants (EP) are characterized by their difficulty to be removed through biological oxidation processes (BOPs); they persist in the environment and could have adverse effects on the aquatic ecosystem and human health. The electro-oxidation (EO) process has been successfully used as an alternative technique to oxidize many kinds of the aforementioned pollutants in wastewater. However, the EO process has been criticized for its high energy consumption cost and its potential generation of by-products. In order to decrease these drawbacks, its combination with biological oxidation processes has been reported as a solution to reduce costs and to reach high rates of recalcitrant pollutants removal from wastewaters. Thus, the location of EO in the treatment line is an important decision to make, since this decision affects the formation of by-products and biodegradability enhancement. This paper reviews the advantages and disadvantages of EO as a pre and post-treatment in combination with BOPs. A perspective of the EO scale-up is also presented, where hydrodynamics and the relationship of A/V (area of the electrode/working volume of the electrochemical cell) experiments are examined and discussed.

자연형 도로 비점오염저감시설의 저감효율 및 적용성 연구 (A Study on Removal Efficiency and Applicability of Natural Type Road Non-point Pollutant Reduction Facilities)

  • 이상혁;조혜진;김이형
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.9-17
    • /
    • 2014
  • PURPOSES : The purpose of this study is to assess removal efficiency of non-point pollutants and applicability for non-point pollutant reduction facilities by conducting the demonstration project operation. METHODS : In order to analyze removal efficiency of non-point pollutants for facilities such as a grassed swale, a small constructed wetland, a free water surface wetland, a horizontal sub-surface flow wetland, and a sand filtration, the field data including specifications of facilities, rainfall, inflow and runoff rainfall effluent etc. was acquired after occurring rainfall events, and the acquired data was analyzed for removal efficiency rate to assess road non-point pollutants facilities using event mean concentration (EMC) and summation of load (SOL) methods. RESULTS : The results of analyzing rainfall effluent, non-point pollutant sources showed that total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN), total phosphorus (TP), chrome (Cr), zinc (Zn), and lead (Pb) can be removed through non-point pollutant reduction facilities by 60.3% ~ 100%. Especially removal efficiency of TSS, COD and BOD is relatively higher than removal efficiency of other non-point pollutant sources in all kind of non-point pollutant facilities. CONCLUSIONS : Based on the result of this study, even though natural type of non-point pollutant reduction facilities for roads occupy small areas comparing with drainage basin areas, most of non-point pollutant sources would be removed through the facilities.

인공습지를 이용한 호소 유입 비점오염물질 제거 효율 평가: 대청호 안내천 습지 사례 분석 (Removal Efficiency of Non-point Source Pollutants through Constructed Wetland: Case Study of Annaecheon Wetland in Daecheong Reservoir)

  • 박별님;조영철
    • 환경영향평가
    • /
    • 제32권5호
    • /
    • pp.291-304
    • /
    • 2023
  • 녹조로 널리 알려진 남조류 과다증식은 심미적 불쾌감뿐만 아니라 독성물질을 생성하기 때문에 댐 수질 관리에 있어 큰 문제가 되고 있다. 녹조 발생을 억제하기 위하여 호소 유역으로부터 유입되는 비점오염물질 특히, 영양염류 저감이 필요하다. 본 연구에서는 친환경적 방법으로 알려진 인공습지의 장기간 운영 결과를 분석하여 비점오염물질 제어 수단으로서 인공습지의 적용 가능성 및 공정운영 관련 기초자료를 구축하기 위하여, 2014~2020년 동안 대청호 유역에 위치한 안내천 인공습지의 오염물질 처리효율을 분석하였다. 분석 결과, BOD 14.3%, COD 17.9%, SS 50.0%, T-N 19.0%, T-P 35.4%로 인공습지가 오염 물질 제거에 효과적임을 확인하였다. 계절별 처리효율은 오염물질별로 다른 경향을 보였는데, 주로 미생물의 반응에 의해 제거되는 BOD, COD, T-N은 겨울철에 비해 봄~가을에 높은 처리효율을 나타내었다. 그러나 수생식물에 의해 주로 제거되는 T-P는 처리효율에 있어 겨울에도 안정적인 처리효율을 나타내 호소 유입부하를 저감하는 데 효과적임을 확인하였다. 오염부하에 따른 제거율은 모든 오염물질이 유입수의 중간농도 및 고농도 구간에서 유출수 농도가 통계적으로 유의하게 감소한 것으로 나타났다. 이는 초기 강우와 같은 고부하 조건에서도 인공습지가 호소로 유입되는 비점오염물질을 안정적으로 제거해 호소의 부영양화를 억제하는 데 효과적으로 활용될 수 있음을 보여준다. 다만, 습지는 자연정화에 기반한 시설로 인위적인 공정 제어가 어렵기 때문에 향후 유역별 특성에 따라 다양한 운영사례 연구가 정립된다면 우리나라 호소의 녹조 문제 해결을 위해 유용한 방법이 될 것으로 판단된다.

산업체 VOC/악취 저감기술 (Removal Technologies of Odor and Volatile Organic Compounds from Industrial Processes)

  • 추수태;남창모
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.289-297
    • /
    • 2004
  • Emissions of volatile organic compounds and odors from various industrial processes not only pollute surrounding life environments, but also lead to the deterioration of the working environments, causing various industrial health and business problems. These pollutants are usually stimulating, irritating, malodorous and sometimes carcinogenic, Which should be reduced in the pollutants formation, stage, but the practical processes do not allow This paper describes the major sources of VOC and odors, and their sampling/analysis methods. Furthermore, various removal technologies for these pollutants are suggested, which particularly include the characteristics of the catalytic and scrubber/carbon filter combined process, and even process design technologies.

  • PDF

SPCP를 이용한 오염물질 ($SO_2$, NOx) 처리 특성 (The Characteristics of the Treatment of Pollutants ($SO_2$, NOx) Using Surface Discharge Induced Plasma Chemical Process)

  • 봉춘근;부문자
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.333-342
    • /
    • 1998
  • Plasma process has great possibilities to remove SOx, NOx simultaneously with high treatment efficiency and is expected to be suitable for small or middle plants. It was accomplished to evaluate SO2, NOx control possibility and achieve basic data to control pollutants by use of Surface Discharge Induced Plasma Chemical Process (SPCP) in this study. O3 generation characteristics by discharge of a plate was proportional to O2 concentration and power consumption and inversely proportional to temperature and humidity, In case of dry air, NOx was highly generated by N2 and O2 in air during the plasma discharge process but it was decreased considerably as H2O was added. SO2 removal efficiency was very high, and removal rate was 170,350 mEA at 30,50 watt respectively in flue gas which is usually contain HIO. NOx removal efficiency was about 57% at 40 watt power consumption with 7.5% humidity. It is estimated that H2O has an important role in reaction mechanism with pollutants according to plasma discharge.

  • PDF

BASELINE MEASUREMENTS ON THE PERFORMANCE OF FOUR CONSTRUCTED WETLANDS IN TROPICAL AUSTRALIA

  • Fell, A.;Jegatheesan, V.;Sadler, A.;Lee, S.H.
    • Environmental Engineering Research
    • /
    • 제10권6호
    • /
    • pp.316-327
    • /
    • 2005
  • Constructed wetlands provide several benefits that are not solely limited to storm water management and are becoming common in storm water management. In this research, four recently constructed wetlands underwent in situ and laboratory water sampling to determine their efficiency in removing storm water pollutants over a 5-month period. From the sampling results, it was determined that each of the wetlands was able to reduce the concentration of pollutants in the stormwater. To aid in the assessment of the wetlands against each other, a model was developed to determine the extent of removal of stormwater pollutants over the length of the wetland. The results from this model complimented the data collected from the field. Improvements, such as increased amounts of vegetation were recommended for the wetlands with the aim of increasing the effectiveness. Further investigations into the wetlands will allow for better understanding of the wetland's performance.

Applied Horticultural Biotechnology for the Mitigation of Indoor Air Pollution

  • Torpy, Fraser R.;Pettit, Thomas;Irga, Peter J.
    • 인간식물환경학회지
    • /
    • 제21권6호
    • /
    • pp.445-460
    • /
    • 2018
  • Exposure to indoor air pollution is an emerging world-wide problem, with growing evidence that it is a major cause of morbidity worldwide. Whilst most indoor air pollutants are of outdoor origin, these combine with a range of indoor sourced pollutants that may lead to high pollutant levels indoors. The pollutants of greatest concern are volatile organic compounds (VOCs) and particulate matter (PM), both of which are associated with a range of serious health problems. Whilst current buildings usually use ventilation with outdoor air to remove these pollutants, botanical systems are gaining recognition as an effective alternative. Whilst many years research has shown that traditional potted plants and their substrates are capable of removing VOCs effectively, they are inefficient at removing PM, and are limited in their pollutant removal rates by the need for pollutants to diffuse to the active pollutant removal components of these systems. Active botanical biofiltration, using green wall systems combined with mechanical fans to increase pollutant exposure to the plants and substrate, show greatly increased rates of pollutant removal for both VOCs, PM and also carbon dioxide ($CO_2$). A developing body of research indicates that these systems can outperform existing technologies for indoor air pollutant removal, although further research is required before their use will become widespread. Whilst it is known that plant species selection and substrate characteristics can affect the performance of active botanical systems, optimal characteristics are yet to be identified. Once this research has been completed, it is proposed that active botanical biofiltration will provide a cheap and low energy use alternative to mechanical ventilations systems for the maintenance of indoor environmental quality.

건식세정기에서의 오염물 동시제거를 위한 고온3계평형 모델의 적용과 예비설계에의 응용 (Application of High-temperature 3-phase Equilibrium Distribution to Dry Scrubber for the Simultaneous Removal of $SO_2$ and Vinyl Chloride)

  • 구자공;백경렬
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.85-96
    • /
    • 1990
  • Simultaneous removal efficiencies of hydrophilic and hydrophobic gaseous pollutants are experimentally determined, and the macroscopic removal mechanism of pollutants in a dry scrubber is analyzed using the extended model of three phase equilibrium distribution of pollutant at high temperatures that can describe the different morphological conditions of adsorbent and water at varying relative humidities. For the simplicity, the inside of spray dryer is divided into three regions of ; (1) absorption, (2) three-phase equilibrium, and (3) adsorption, and the removal efficiencies of each pollutants at three regions are observed at different experimental conditions to estimate the effects of important parameters of dry scrubber. The laboratory experiments simulate the three regions of spray dryer with the temperature control and thus evaporation rate of water from the slurry particle. $SO_2$ as a hydrophilic gaseous pollutant and vinyl chloride as a hydrophobic toxic gas are selected for the future field application to soid waste incineration, and the two types of slurry are made of the two sorbents ; 10 wt.% $Ca(OH)_2$, and 10 wt.% NaOH. Result of temperature effect shows the height of absorption plus three-phase region is decreased as the operation temperature is increased, which results in the lower removal efficiency of $SO_2$ but higher removal for vinyl chloride in the adsorption region of dry scrubber. The removal efficiency of $SO_2$ is higher by NaOH slurry than by $Ca(OH)_2$ slurry due to the hygroscopic nature of NaOH, while the removal of vinyl chloride is higher in $Ca(OH)_2$ case. From the analysis of redults using three-phase equilibrium distribution model, the effective two-phase partition coefficients can be obtained, and the possible extention in the application of the three-phase equilibrium model in a dry scrubber design has been demonstrated.

  • PDF