• Title/Summary/Keyword: Pollutants discharge

Search Result 250, Processing Time 0.031 seconds

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 2. Assessment of the Pollution of Heavy Metals in Seawater around Major Shipyards in Summer 2010 (국내 조선소 주변해역의 해양오염 현황 - 2. 2010년 하계 대형조선소 주변 해수의 중금속오염 평가)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • In order to elucidate the current state of marine pollution of heavy metals around major shipyards in Korea, seawater samples were collected at eleven sampling stations and four control stations around 4 major shipyards located in the southeastern coast of Korea in summer 2010, and 6 kinds of metals such as copper(Cu), zinc(Zn), iron(Fe), cadmium(Cd), lead(Pb) and mercury(Hg) in seawater samples were analyzed. The analyses of heavy metals in seawater showed that the mean Cu concentrations in seawater around 4 major shipyards were in the range of $0.817{\sim}1.638{\mu}g/L$ which were lower than Korean environmental standards of $20{\mu}g/L$ for the protection of human health(PHH) and of $3{\mu}g/L$ for short-term protection of marine ecosystem(SPME) but higher than Cu concentration at control station by a factor of up to 2.75. The mean Zn concentrations were in the range of $0.228{\sim}0.567{\mu}g/L$ which were lower than Korean environmental standards of $100{\mu}g/L$ for PHH and $34{\mu}g/L$ for SPME but higher than Zn concentration at control station by a factor of up to 5.91. The mean Fe concentrations were in the range of $3.332{\sim}7.410{\mu}g/L$ which were higher than Fe concentration at control station by a factor of up to 6.75. The mean Cd concentrations were in the range of $0.013{\sim}0.028{\mu}g/L$ which were lower than Korean environmental standards of $10{\mu}g/L$ for PHH and $19{\mu}g/L$ for SPME but higher than Cd concentration at control station by a factor of up to 2.33. The mean Pb concentrations were in the range of $0.007{\sim}0.126{\mu}g/L$ which were lower than Korean environmental standards of $50{\mu}g/L$ for PHH and $7.6{\mu}g/L$ for SPME. The mean Hg concentrations were in the range of $0.002{\sim}0.004{\mu}g/L$ which were lower than Korean environmental standards of $0.5{\mu}g/L$ for PHH and $1.8{\mu}g/L$ for SPME. Although the concentrations of metals such as Cu, Zn and Fe which were used in shipbuilding works were lower than Korean environmental standards for PHH and SPME, the fact that the concentrations of Cu, Zn and Fe at sampling stations around major shipyards were higher than those at control stations implies that the works in shipyards had some effects on marine water quality around shipyards. Therefore, marine environment management such as the prevention and control of the discharge of various pollutants from shipyards is required on national level.

Biogeochemical Study of Dissolved Organic and Inorganic Compounds under Oxic/Anoxic Environment in Lake Shihwa (시화호 산화-환원 환경하의 용존 유, 무기 화합물의 생지화학적 연구)

  • Park, Yong-Chul;Park, Jun-Kun;Han, Myong-Woo;Son, Seung-Kyu;Kim, Moon-Koo;Huh, Seong-Hoi
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.53-68
    • /
    • 1997
  • Lake Shihwa, artificially constructed since 1988, shows a typical two-layered system depending on strong haline density stratification. Sill of the water gate at 6 m depth greatly restricts physical mixing with outer seawater and circulation in the lake, and contributes to the enhancement of anoxic environment in the deeper layer. With this enclosed physical environment, Lake Shihwa receives enormous amounts of organics, ammonia, and other pollutants from the neighboring municipal and industrial complexes through six major streams, thus developing biogeochemical differentiation of anoxic to suboxic environment in the high saline bottom water and highly eutrophicated brackish surface water. This study investigated vertical structures, biogeochemical behaviors and processes of various organic and inorganic compounds around oxic-anoxic interface. Nitrite and nitrate rapidly decreased below the pycnocline where about $1{\times}10^8$ tons of hypoxic bottom water exist. In this bottom layer, ammonium ranged from 75 to 360 ${\mu}M$ mainly resulting from deamination of dissolved organic nitrogen and ammonification of precipitated organic particles. Despite large amounts of surface water discharge and dilution by outer seawater inflow about $3{\times}10^8$ tons from April to August, 1996, bottom layer did not show any improvement of water quality and maintained highly reduced environment. The main reason seems to be imbalance between ineffectiveness of dilution due to shallow depth and large surface area, overloaded POC influx from the eutrophicated surface biological activity, and poor replenishment of oxygen in this artificial lake system. Therefore, as long as current salinity dependent two-layered system maintains with its physical limitations, any improvement of water quality cannot be foreseen in Lake Shihwa.

  • PDF

Electrochemical Treatment of Dye Wastewater Using Fe, RuO2/Ti, PtO2/Ti, IrO2/Ti and Graphite Electrodes (RuO2/Ti, PtO2/Ti, IrO2/Ti 및 흑연전극을 이용한 염료폐수의 전기화학적 처리)

  • Kim, A Ram;Park, Hyun Jung;Won, Yong Sun;Lee, Tae Yoon;Lee, Jae Keun;Lim, Jun Heok
    • Clean Technology
    • /
    • v.22 no.1
    • /
    • pp.16-28
    • /
    • 2016
  • Textile industry is considered as one of the most polluting sectors in terms of effluent composition and volume of discharge. It is well known that the effluents from textile dying industry contain not only chromatic substances but also large amounts of organic compounds and insolubles. The azo dyes generate huge amount of pollutions among many types of pigments. In general, the electrochemical treatments, separating colors and organic materials by oxidation and reduction on electrode surfaces, are regarded as simpler and faster processes for removal of pollutants compared to other wastewater treatments. In this paper the electrochemical degradation characteristics of dye wastewater containing CI Direct Blue 15 were analyzed. The experiments were performed with various anode materials, such as RuO2/Ti, PtO2/Ti, IrO2/Ti and graphite, with stainless steel for cathode. The optimal anode material was located by changing operating conditions like electrolyte concentration, current density, reaction temperature and initial pH. The degradation efficiency of dye wastewater increased in proportion to the electrolyte concentration and the current density for all anode materials, while the temperature effect was dependent on the kind. The performance orders of anode materials were RuO2/Ti > PtO2/Ti > IrO2/Ti > graphite in acid condition and RuO2/Ti > IrO2/Ti > PtO2/Ti > graphite in neutral and basic conditions. As a result, RuO2/Ti demonstrated the best performance as an anode material for the electrochemical treatment of dye wastewater.

Water Quality and Heavy Metals in the Surface Seawaters of the Saemangeum Area during the Saemangeum-dike Construction (새만금 방조제 체절 과정 중 새만금 주변해역 표층수의 수질과 중금속 분포 특성)

  • Kim, Kyung-Tae;Kim, Eun-Soo;Kim, Seong-Soo;Park, Jong-Soo;Park, Jun-Kun;Cho, Sung-Rok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.35-46
    • /
    • 2009
  • In order to investigate spatial and temporal distributional characteristics of major water qualities in the Saemangeum area during the Saemangeum dike construction, salinity, COD, dissolved nutrients(DIN, Silicate) and heavy metals were analyzed from the surface water collected in April, May, August and November 2002. The overall value of Salinity, COD, DIN, and silicate in surface waters were in the range of $13.08{\sim}31.96\;psu$, $0.12{\sim}3.43\;mg/L$, $0.001{\sim}2.638\;mg/L$, and $0.010{\sim}3.181\;mg/L$, respectively. The COD and DIN in each survey showed the highest concentration at the mouth of Mangyeong river estuary(St. 1) where freshwater flow into the Saemangeum area. The concentrations of nutrients were high in the inner part of the Saemangeum dike with low-salinity, and low nutrients in the outer part of the dike with high-salinity, which strongly indicated that concentrations were adjusted by physical mixing. The ranges of dissolved metals and acid-soluble Hg in surface seawater were $0.006{\sim}0.115{\mu}g/L$ for Co, $0.26{\sim}0.114{\mu}g/L$ for Ni, $0.14{\sim}0.93{\mu}g/L$ for Cu, $0.04{\sim}0.53{\mu}g/L$ for Zn, $0.010{\sim}0.043{\mu}g/L$ for Cd, $0.010{\sim}0.795{\mu}g/L$ for Pb, and $0.25{\sim}4.16{\mu}g/L$ for Hg. The highest concentrations of some metals except for Cd were found at the estuary(Sts. 1 or 3). In most cases, a decreasing order of metal concentrations towards open sea(low-salinity$\rightarrow$high-salinity) was observed and showed positive relationship with DIN and silicate caused by land base pollutants input. On the other hand, due to Cd desorption from suspended solids in saline water, dissolved Cd concentrations were high in high-salinity area and low in low-salinity. In November, Co, Zn, Cu and Pb were relatively high in the northern area of the outer-side of Saemangeum, which was only influenced by the Geum river discharge. The concentrations of most dissolved metals of this study were lower than those of the past data in this area, but higher than those in Lena river estuary under the pristine environment.

  • PDF

Biodegradation of Phenol by Comamonas testosteroni DWB-1-8 Isolated from the Activated Sludge of Textile Wastewater (섬유 폐수 활성 슬러지에서 분리한 Comamonas testosteroni의 생물학적 페놀 분해)

  • Kwon, Hae Jun;Choi, Doo Ho;Kim, Mi Gyeong;Kim, Dong-Hyun;Kim, Young Guk;Yoon, Hyeokjun;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.156-161
    • /
    • 2020
  • Since industrialization, the production and utilization of various chemicals has contributed to improving the quality of our lives, but the subsequent discharge of massive waste is inevitable, and environmental pollution is becoming more serious every day. Exposure to chemicals as a result of environmental pollution is having a negative effect on human health and the ecosystem, and cleaning up the polluted environment that can affect our lives is a very important issue. Toxic aromatic compounds have been detected frequently in soil, groundwater, and wastewater because of the extensive use of oil products, and phenol, which is used to produce synthetic resins, textiles, and dyes, is one of the major pollutants, along with insecticides and preservatives. Phenol can cause dyspnea, headache, vomiting, mutation, and carcinogenesis. Phenol-degrading bacterium DWB-1-8 was isolated from the activated sludge of textile wastewater; this strain was identified as Comamonas testosteroni by 16S rRNA gene sequencing. The optimal culture conditions for the cell growth and degradation of phenol were 0.7% K2HPO4, 0.6% NaH2PO4, 0.1% NH4NO3, 0.015% MgSO4·7H2O, 0.001% FeSO4·7H2O, an initial pH of 7, and a temperature of 30℃. The strain was also able to grow by using other toxic compounds, such as benzene, toluene, or xylene (BTX), as the sole source of carbon.

A Study on the Forest Vegetation and Soil-environmental Factors Affecting the Water Quality of Iwonch on Stream (이원천 수질에 미치는 삼림식생과 토양환경요인)

  • Bang, Je-Yong;Yang, Keum-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.2
    • /
    • pp.183-190
    • /
    • 2009
  • Characterization of the analysis of forest vegetation, soil environmental conditions and water quality were performed from March 2003 to March 2007. The two basins were characterized by cultivated area (Kaesim reservoir) and mountain area (Jangchan reservoir), and divided into eleven small basins, where dynamics of pollutants, forest vegetation and soil environmental conditions were surveyed. The vegetation can be divided into 10 types by $Z\ddot{u}rich$-Montpellier school's method. Pearson coefficients between vegetation type and water quality were correlated with dissolved oxygen (DO) in the Quercus variabilis community at the 5% level and total phosphorus (TP) in the Larix leptolepis plantation at the 1% level. Especially total phosphorous and total nitrogen increased in small basins where the proportion of cultivated and residential area increased. The analysis of influences of pollutant discharge on water quality showed that pollutant charge was very low in forest land area ($Y_{T-P}$=-0.0017X+0.2215, r=0.16, $Y_{COD}$=- 0.0395X+8.5051 r=0.47). The soil types of western area were comparatively simple, but those of eastern area were complicated with regosols, red-yellow soils, lithosoles, etc. The pH, total solid (TS) and volatile substance (VS) of the forest and agricultural land soils collected in each site were 5.4~6.9, 75.8~80.2%, and 3.80%~5.80%, respectively. According to the analytical result of soil environmental conditions, heavy metal contents fell short to the mean value of natural conditions. Runoff amount (Y) and depth of topsoil (X) were negatively correlated, $Y_{ron}=-1.0088X_{top}+35.378$ (r=0.68). The correlation was much lower in up-stream but much higher in down-stream, because permeation into soil particle was larger on down-stream due to its more or less gentle slope. Pearson coefficients between soil pH and water pH were statistically significant at 1% level.

A Study on the Characteristic of Pollutants of Water Quality and Sediments in Gul-po Stream Basin (굴포천 유역 내 수질 및 퇴적물의 오염물질 특성 파악에 관한 연구)

  • Ahn, Tae-Woong;Jung, Jae-Hoon;Kim, Tae-Hoon;Kim, Sea-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.495-503
    • /
    • 2012
  • The water quality of Gul-po Stream, the subject of this study, has been deteriorating because of the inflow of domestic sewage and the industrial wastewater due to industrialization and the problems relating to the structure of river including slow flow rate and the covering of river. In particular, the domestic sewage from small-medium sized factories by the river and large-scale industrial complex by the upper and middle streams of the river, and the domestic sewage from increasing population due to the regional development are the main pollution sources. Thus, this study aims to survey the water quality and the sediment affecting Gul-po Stream; monitor the state of pollution in water body; assess the yield of sediment and investigate the water quality of river and the problems arising from sediment; and then suggest reasonable ways to improve the situation. The findings from surveying pollution load shows the discharge increases up to average 72.8 times from the upper stream to the downstream of Gul-po Stream, and pollution load increases up to: SS 111 times, BOD 150 times, COD 145 times, the nutrient T-N 222 times and T-P 312 times on an average basis. As for the pollution concentration range, ignition loss is 1.29~12.43%; COD is 4,015~37,547 kg/day; T-N and T-P 94.8~352.5 kg/day and 81.8~372.3 kg/day, respectively. As for the releasing rate of sediment, T-N is -14.46~$156.61mg/m^2/day$; T-P is -11.53~$26.10mg/m^2/day$, indicating the likelihood of internal contamination due to the elution of sediment. This study is expected to be used as basic data to manage Gul-po Stream basin.

A Study on User's Opinion for Designing of Multi-Functional Plant Applications (복합적 기능의 식물 애플리케이션 디자인을 위한 사용자 조사)

  • Lee, Ha Na;Park, Han Na;Paik, Jin Kyung
    • Korea Science and Art Forum
    • /
    • v.37 no.4
    • /
    • pp.297-308
    • /
    • 2019
  • Air pollution due to the fine dust level updating every day, and the problem of indoor air pollution due to ventilation difficulties and indoor discharge pollutants is also serious. In order to improve the indoor air quality, the air purification effect using the plants is prominent. In this study was started to investigated the living environment of modern people, the risk of indoor air pollution and the improvement function of plants, and to activate plant application. The purpose of this study is to analyze the main functions and design status of domestic and overseas plant - related applications, and to understand the actual use of modern plant applications and to help them learn more convenient plant - related knowledge. Therefore, this paper attempted to establish a basis for suggesting a new plant application by conducting a survey on the health effects of indoor air pollution and user awareness of plant - related applications. The results and contents of the study are as follows. First, as a theoretical review, indoor air pollution is more dangerous to modern people who have a high proportion of indoor living time and adversely affects their health. In order to solve such a problem, it has been shown that air conditioning and stress reduction can be effectively achieved by placing plants in the indoor space. Second, the analysis of the previous study shows the risk of indoor air pollution and its adverse effects on health. In addition, I have been able to find some researches related to the improvement of the indoor air by using the air purifying plants, and I can see the improvement of the user's behavior through the development or improvement of the application. Third, as a result of the survey on the status of domestic and overseas plant application, the main function of the application having high installation number was watering notification, provision of basic information of plants, and most of the functions were plant discerment through cameras. Fourth, most of the survey respondents have either raised or raised plants. Those who have little experience with plant applications have also shown positive feedback in the future on the use of plant-related applications. In addition, due to social problems such as air pollution, air purification using plants and functional plants showed high interest. Based on these results, we propose the need for a multi-functional plant application that can improve the indoor air pollution and facilitate the provision of information related to it.

Applicability Analysis of the HSPF Model for the Management of Total Pollution Load Control at Tributaries (지류총량관리를 위한 HSPF 모형의 적용성 분석)

  • Song, Chul Min;Kim, Jung Soo;Lee, Min Sung;Kim, Seo Jun;Shin, Hyung Seob
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.1-14
    • /
    • 2022
  • The total maximum daily load (TMDL) implemented in Korea mainly manages the mainstream considering a single common pollutant and river discharge, and the river system is divided into unit watersheds. Changes in the water quality of managed rivers owing to the water quality management in tributaries and unit watersheds are not considered when implementing the TMDL. In addition, it is difficult to consider the difference in the load of pollutants generated in the tributary depending on the conditions of the water quality change in each unit watershed, even if the target water quality was maintained in the managed water system. Therefore, it is necessary to introduce the total maximum load management at tributaries to manage the pollution load of tributaries with a high degree of pollution. In this study, the HSPF model, a watershed runoff model, was applied to the target areas consisting of 53 sub-watersheds to analyze the effect of water quality changes the in tributaries on the mainstream. Sub-watersheds were selected from the three major areas of the Paldang water system, including the drainage basins of the downstream of the South Han-River, Gyeongan stream, and North Han-River. As a result, BOD ranged from 0.17 mg/L to 4.30 mg/L, and was generally high in tributaries and decreased in the downstream watershed. TP ranged from 0.02 mg/L - 0.22 mg/L, and the watersheds that had a large impact on urbanization and livestock industry were high, and the North Han-River basin was generally low. In addition, a pollution source reduction scenario was selected to analyze the change in water quality by the amount of pollution load discharged at each unit watershed. The reduction rate of BOD and TP according to the scenario changes was simulated higher in the watershed of the downstream of the North Han-River and downstream and midstream of the Gyeongan stream. It was found that the benefits of water quality reduction from each sub-watershed efforts to improve water quality are greatest in the middle and downstream of each main stream, and it is judged that it can be served as basic data for the management of total tributaries.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.