• Title/Summary/Keyword: Pole Transformer

Search Result 108, Processing Time 0.028 seconds

Broadband Double-Cone Antennas for Measuring Partial Discharge (부분방전 측정용 이중 원추형 광대역 안테나)

  • Jang, Seung-Hoon;Choi, Beom-jin;Lim, Dong-Young;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1050-1057
    • /
    • 2015
  • This paper presents the characteristics of broadband double-cone antennas. The antenna is used to measure electromagnetic fields(2~5 GHz) radiated from a primary or a secondary electrode of a pole-transformer when partial discharge occurs inside the pole-transformer. The theoretical analysis is conducted using commercial software based on a finite difference time domain(FDTD) method. The parameters are a radius, and a height of the broadband double-cone antennas, and the number of posts on a ground plane. This paper examines influences of structural parameters of the broadband double-cone antennas on return loss. The results show that a condition for an optimum structure of broadband double-cone antennas exists. It also shows that the broadband double-cone antennas have radiation patterns similar to those of a dipole antenna. Therefore the broadband double-cone antennas are appropriate for the measurement of radiated electromagnetic fields from the pole-transformer. To verify the theoretical analysis, computed results are compared to experimental results.

A Study on the Aging Diagnosis of Transformer oil by Spectrometric and Electroanalytical Methods (분광광도법 및 전기분석법을 이용한 절연유의 경년열화 진단에 관한 연구)

  • 김경렬;곽희로;윤영자;남궁미옥;이동준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.15-20
    • /
    • 1998
  • The furfural, generated by decomposition of insulating paper, the amount of metal in insulating oil, and tano(electrical properties of insulating oil)have been studied for the insulating oil in pole transformer with accelarated thermal aging test. It has been found that tan $\delta$ is affected by adding components of the transformer. The examination of amount of metal, which exhibits catalytic behavior to oxidation of insulating oil, suggested that the amounts of copper increase with degradation time. A comparison between tano and copper amount suggested that the amounts of copper for attention are above 0.2[pp]). Finally, the examination of amount of furfural revealed that the amounts of furfural increase with degradation time. As a consequence, these results could be used for diagnosis of pole transformer.former.

  • PDF

A Monitoring Technique of Pole Transformers using AC Bridge Circuit (AC 브리지 회로에 의한 주상 변압기의 감시 기법)

  • Yoon, Yong-Han;Min, Kyeoung-Rae;Choi, Do-Hyuk;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.544-546
    • /
    • 2000
  • This paper presents a monitoring technique of pole transformers using AC bridge circuit. And to detect the capacitance in oil more effectively, this paper used AC bridge circuit. The sensor in oil which could be placed inside of the distribution transformer can measures the changes of capacitance in oil. And with the sensing of the upper part's capacitance, it is possible to determine the changes of the oil height. Establishment of the proposed system helps to build the confidence in monitoring of the pole transformers.

  • PDF

A Coupled Line Impedance Transformer for High Termination Impedance with a Bandpass Filtering Response

  • Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2018
  • In this study, a short-ended coupled line with a short-circuit stub transmission line bandpass filtering impedance transformer is presented. The general designed equations are derived on the basis of circuit theory. The design curves are provided to examine the characteristic of the proposed impedance transformer. The proposed circuit is suitable for high termination impedance. To validate the design formulas, a $400-50{\Omega}$ impedance transformer is designed and fabricated at the operating center frequency ($f_0$) of 2.6 GHz. The measured results show a good agreement with the simulation. The measured insertion and return losses are 0.6 dB and 22.5 dB at $f_0$, respectively. The measured return loss is higher than 20 dB within the passband frequency of 2.51-2.7 GHz. Moreover, the stopband attenuation is higher than 25 dB from DC to 1.64 GHz of the lower stopband and from 3.12 GHz to 6.4 GHz of the higher stopband.

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

A Study on the Thermal distribution of the 30kVA Pole Transformer Due to the Rated load (30kVA 주상 변압기의 정격부하에 의한 열분포에 관한 연구)

  • Kim, M.K.;Kim, J.T.;Koo, J.Y.;Song, K.D.;Cho, Y.O.;Ha, B.N.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.292-295
    • /
    • 1991
  • The life of the transformers is significantly dependent upon the rate of thermal deterioration in the employed insulating materials. Therefore, the study should be based on hot-spot temperature considerations for the life expectancy and possible overload of transformer. We have measured directly temperature of the winding using thermocouples and these test results are compared with those obtained from computer simulation. In this work, our fundamental investigations are well described for the analysis in the thermal distribution of the oil-immersed transformer with the rating of 30kVA.

  • PDF

A development on remote monitoring technology of distribution transformer using CDMA wireless data communication (CDMA무선 데이터통신을 이용한 배전용변압기 원격감시 기술개발)

  • Park, Chang-Ho;Rho, Whang-Rae;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.483-485
    • /
    • 2000
  • This paper presents the operation technology and the remote monitoring system of distribution pole transformer. Especially, this system uses CDMA wireless data communication network as media which is serviced on a national scale. It has four major components such as sensor for measuring the secondary voltage and currents of distribution transformer, CDMA wireless modem for data modulating/demodulating, communication media for sending/receiving of data, and PC server for monitoring the results of sensing or computing information. This paper also describes the configuration of each component's functions with its development process.

  • PDF

Development of Wireless Monitoring System for Distribution Transformer (배전용 변압기의 무선 부하감시 시스템 개발)

  • Jung, Joon-Hong;Kang, Tae-Goo;Kim, Il-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.414-415
    • /
    • 2008
  • In this paper, we consider the development methodology of wireless monitoring system for a distribution transformer. The master/ slave devices are installed in the power distribution feeder and measure the current state of pole or ground transformers. After measuring, the devices send the measurement data to operating room through the wireless network such as RF and CDMA so that the power distribution supervisor can prevent a distribution transformer damaging caused by overloads and imbalance of loads.

  • PDF

The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System (전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석)

  • Moon, Won-Sik;Cho, Sung-Min;Shin, Hee-Sang;Lee, Hee-Tae;Han, Woon-Ki;Choo, Dong-Wook;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

The Evaluation of Thermal Aging Characteristics in Insulating Paper for the Use of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열열화 특성 평가)

  • Lee, Byung-Sung;Song, Il-Keun;Lee, Jae-Bong;Park, Dong-Bae;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.100-103
    • /
    • 2003
  • The primary insulation system used in an oil-filled transformer is kraft paper, wood, porcelain and oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF