• 제목/요약/키워드: Polarization resistance method

검색결과 176건 처리시간 0.03초

산화피막이 있는 철근의 분극곡선의 거동에 대한 연구 (The Study on the Behavior of Polarization curve of Reinforcement with Oxidation Layer)

  • 한정섭
    • 한국해양공학회지
    • /
    • 제14권1호
    • /
    • pp.60-66
    • /
    • 2000
  • In order to study for corrosion behavior of reinforcing steel with oxidation layer. Experiments were done with various NaCl concentrations and with immersion time in simulated concrete pore solution(SPS) the characteristics of corrosion behavior were measured by polarization resistance method and cyclic potentiodynamic method. reinforcements were coated by epoxy except corrosion without oxidation layer and it also showed two anodic-nose. by the result of potention dynamic test the potential curve shift to low with time and anodic-nose was appeared with 3% NaCl solution after 15 days. By result of cyclic Potentiodynamic test the type of corrosion was different accoding to concentration.

  • PDF

무도장 내후성 강교량의 Box Girder 내부볼트 연결부에 대한 외부전원식 정기방식효과에 관한 연구 (A study on the effect of the external electric type corrosion resistance for the bolt connection in weathering steel box girders.)

  • 박용걸;김헌태;백찬호;최정열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.988-993
    • /
    • 2004
  • This paper considers corrosion problems in the bolt connection of weathering steel box girder bridge using the external electric type corrosion resistance method which resisted to local corrosion in coated steel surface with contacted air. The weathering steel was created a rust itself in the passive state. but a coated box girder type was easily dew form could be made galvanic cell that accelerated corrosion. so that it was ruled by protection coat with some paint. Therefore, it needed that can be applied the external electric type corrosion resistance method in coated surface. As a result of the test of polarization amount had measured that the weathering steel was higher currents than the general steel by about $5\~10\%$. Therefore. an external electric type corrosion resistance method can be used to protect local corrosion in the coated bolt connection of weathering steel box girders effectively.

  • PDF

SOFC 용 LSCF/CGO 공기극의 제조 및 특성연구 (Synthesis and Characterization of LSCF/CGO Composite Used as SOFC Cathode Materials)

  • 박재량;임탁형;이승복;박석주;신동렬;송락현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.184-186
    • /
    • 2009
  • Composites of LSCF($La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-\delta}$ and CGO(gadolinium doped ceria) is an efficient candidate cathode material with CGO electrolytes. In this study, LSCF with exact perovskite structure was synthesized by using solid state reaction(SSR) method. The optimized temperature to synthesize $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-\delta}$ with rhombohedral structure. was $1100^{\circ}C$. The polarization resistance of the LSCF/CGO(50:50 wt.%) was smaller than those of other composite cathodes. The analysis of the EIS data of LSCF/CGO suggests that the diffusion and adsorption-desorption of oxygen can be the key process in the cathodic reaction of SOFC using LSCF/CGO as cathode material.

  • PDF

Characterization of Ln0.8Sr0.2CoO3-δ (Ln=Gd, Nd, Pr, Sm, or Yb) as Cathode Materials for Low-Temperature SOFCs

  • Choi, Jung-Woon;Kang, Ju-Hyun;Kim, Han-Ji;Yoo, Kwang-Soo
    • 한국세라믹학회지
    • /
    • 제43권12호
    • /
    • pp.758-763
    • /
    • 2006
  • Perovskites with nominal compositions $Ln_{0.8}Sr_{0.2}CoO_{3-\delta}$ (Ln=Gd, Nd, Pr, Sm, or Yb) were fabricated as cathode materials using a solid-state reaction method for low-temperature operating Solid-Oxide Fuel Cells (SOFCs). X-ray diffraction analysis and microstructure observation for the sintered samples were performed. The ac complex impedance was measured in the temperature range of $600-900^{\circ}C$ in air and fitted with a Solartron ZView program. The crystal structure, microstructure, electrical conductivity, and polarization resistance of $Ln_{0.8}Sr_{0.2}CoO_{3-\delta}$ were characterized systematically.

전차선로 가선재의 수용액 부식 특성 (The Aqueous Corrosion Characteristics of Catenary Materials of Electric Railway System)

  • 김용기;장세기;조성일;이재봉
    • 한국철도학회논문집
    • /
    • 제4권2호
    • /
    • pp.62-70
    • /
    • 2001
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as catenary materials of the electric railway system. Since these materials may be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important to investigate the corrosion rates in various corrosive environments. The aqueous corrosion characteristics of catenary materials in aerated acid, neutral and alkali solutions were studied by using immersion corrosion tests, electrochemical measurements and analytical techniques. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization, a.c impedance spectroscopy and galvanic corrosion tests were carried out with these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effects on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

알루미늄 5052 합금의 산화피막 성장 및 내식성 연구 (Study on Corrosion and Oxide Growth Behavior of Anodized Aluminum 5052 Alloy)

  • 지혜정;정찬영
    • 한국표면공학회지
    • /
    • 제51권6호
    • /
    • pp.372-380
    • /
    • 2018
  • Anodization techniques are widely used in the area of surface treatment of aluminum alloys because of its simplicity, low-cost and good corrosion resistance. In this study, we investigated the relationship between the properties (porosity and thickness) of anodic aluminum oxide (AAO) and its corrosion behavior. Aluminum 5052 alloy was anodized in 0.3 M oxalic acid at $0^{\circ}C$. The anodizing of aluminum 5052 was performed at 20 V, 40 V and 60 V for various durations. The corrosion behavior was studied in 3.5 wt % NaCl using potentiodynamic polarization method. Results showed that the pore diameter and thickness increased as voltage and anodization time increased. The relatively thick oxide film revealed a lower corrosion current density and a higher corrosion potential value.

ALBC3 합금의 수소과전압 현상을 이용한 캐비테이션과 전기화학적 특성 (Cavitation and Electrochemical Characteristics Using Hydrogen Overpotential Method for ALBC3 Alloy)

  • 박재철;이승준;김성종
    • 한국표면공학회지
    • /
    • 제44권6호
    • /
    • pp.277-283
    • /
    • 2011
  • In this study, the cavitation test and electrochemical experiments were conducted for ALBC3(Cu-Al) alloy that has an excellent corrosion resistance and cavitation characteristic in sea water. Based on the ASTMG32 regulation, the cavitation test was performed with the cavitation and cavitation erosion tester using piezoelectric effect. The electrochemical characteristics are evaluated with potentiostatic experiments in activation polarization potential range. As a result, cavitation damage is increased proportionally to temperature and time at $30{\mu}m$ amplitude. It is appeared that acceleration period in weight loss presented over 6 hours under the cavitation environment in sea water. In addition, corrosion damages were observed at the potential range of -3.2~-1.4 V as the result of potensiostatic experiments during 12 hours in activation polarization potential range.

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.

EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구 (An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS)

  • 윤창복;박장현;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.87-95
    • /
    • 2020
  • EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식거동에 관한 실험적 연구로서 콘크리트 내부환경을 모사한 Ca(OH)2 포화수용액 침지 및, NaCl 수용액에서의 침지실험을 통해 부식거동을 실험하였다. Nyquist plot의 분석을 통하여 등가회로를 도출하였으며 Ca(OH)2 수용액에서의 계면저항과 분극저항을 비교한 결과 계면저항은 Al ATMS가 가장 우수하였으며 분극저항은 Zn ATMS가 가장 우수한 것으로 나타났다. 시멘트 모르타르에 금속용사 표면처리 된 강재를 매립후 NaCl 수용액에 침지하여 침지 시간에 따른 임피던스 측정에서는 초기 침지 임피던스 측정값은 Zn ATMS시험체가 가장 높았으나 침지 2주후에는 Al ATMS 시험체의 임피던스가 가장 높고 안정적으로 나타났다. 이는 이온화 경향이 높은 Al이 강알칼리 환경에서 지속적으로 산화하며 피막을 형성하였으며, 염소 이온의 침투로부터 강재를 보호하기 때문으로 판단된다.

액체급냉법에 의해 제조한 비정질 Co-Nb-B 합금의 전기화학적 부식 특성 (Electrochemical Corrosion Properties of Amorphous Co-Nb-B Alloys Prepared by Melt-Spinning Method)

  • 김은선;김현구;장희진
    • Corrosion Science and Technology
    • /
    • 제13권4호
    • /
    • pp.152-156
    • /
    • 2014
  • This study was undertaken to examine the electrochemical corrosion properties of an $Co_{80}Nb_{10}B_{10}$ and $Co_{82}Nb_8B_{10}$ amorphous alloys prepared by melt-spinning method under various conditions. The potentiodynamic polarization responses at various levels of pH (pH 2, pH 7, pH 12) showed that the corrosion current rate of $Co_{80}Nb_{10}B_{10}$ alloy is lower than that of $Co_{82}Nb_8B_{10}$ alloy in all levels of pH, implying the general corrosion resistance of the alloy with higher Nb content is better than that with higher Co content. The pitting potential of $Co_{80}Nb_{10}B_{10}$ alloy was also better than that of $Co_{82}Nb_8B_{10}$, evidenced by the higher pitting potential. Nb is thought to be effective in increasing the protectiveness of the passive film and hence to improve the corrosion resistance of Co-Nb-B alloys.