• Title/Summary/Keyword: Polarity test

Search Result 109, Processing Time 0.032 seconds

A Study on the Polarity Discrimination Method of the Stator Windings for 3 Phase Induction Motors based on the Residual Magnetism and I Winding Connection (잔류자기와 I 결선에 의한 3상유도전동기 고정자 권선의 극성판별법에 대한 연구)

  • Choi, Soon-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.72-77
    • /
    • 2015
  • When connecting 6 lead wires from stator windings to the terminals of 3 phase induction motors for Y or ${\triangle}$ connection, it is feared that the polarities of windings could be reversed each other if the wire tags are lost or erased, resulting in inadmissibly high current to motors in case of starting. To protect motors against such situations, some test procedures are necessary during wire connection which need to be easy ways to electricians without particular tools except a general multi-tester and with less time-consuming in the field. This study focuses on a test measure to satisfy these requirements which is able to provide them a convenient procedure for winding polarity discrimination considering the field condition. Here, the proposed measure utilizes the residual magnetism of the rotor and checks the indication of voltage or current at windings which are induced by the residual flux of rotor when rotating it by hands with 3 stator windings connected in the form of I connection. Principle characteristics and experiment results for this method are analyzed in the view of the effectiveness and applicability for the winding polarity discrimination.

Polarity Verification of Direction Cosine Matrix of Gyro Sensor Using The Earth Rotational Rate (지구 회전 각속도를 이용한 자이로센서의 방향코사인행렬 극성검증)

  • Oh, Shi-Hwan;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.49-55
    • /
    • 2011
  • A Direction Cosine Matrix (DCM) of each satellites sensor/actuator which contains an directional information of sensor/actuator is implemented in the on-board flight software. In order to verify the polarity of direction cosine matrix, it is mostly used that an actual sensor/actuator output is compared with the expected output value which responses to the pre-defined external stimulus to the sensor/actuator. For the gyro sensors, the Earth rotational rate can be used as an external input for the polarity verification of DCM, without using an artificial stimulus. In this study, the polarity of gyro DCM is checked and verified using the several test data which have been acquired during the different system level test phases. Finally the polarity of DCM was successfully verified using the Earth rotational rate.

Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures (불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성)

  • Lee, B.H.;Oh, S.K.;Baek, Y.H.;Ahn, C.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

Study on IPT Characteristics of LSR / Nano Silica Composites for HVDC (HVDC용 LSR/Nano Silica Composites의 IPT특성 연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • Only the power is converted from AC to DC, in accordance with IEC 60587 based test method, in order to develop the LSR(Liquid Silicone Rubber) insulator material for HVDC, the experiment of Inclined Plate Tracking and Erosion Resistance was conducted. A contaminant (2.5 mS/cm: ammonium chloride) was applied at a rate of 0.3 ml/min and a voltage of ${\pm}3.5kV$, and was evaluated on the basis of 60 mA/2s. The samples were prepared by dispersing LSR/Nano silica_25wt% Composites in LSR. The erosion phenomena of surface discharge and tracking due to DC polarity and negative polarity were measured by image, leakage current maximum and thermal camera. The thermal imaging camera measured the surface temperature generated by the joule heat of the leakage current due to the drying discharge and the conductive current. After the measurement, the tracking and erosion mechanisms were evaluated for erosion weight, erosion depth and erosion length. Positive and negative polarity of LSR/Nano Silica_25wt% composite Tracking and erosion results show that positive polarity is more severe than negative polarity.

The Development and Validation of BASS(Bi-axis Analogue Sun Sensor) Stimuli Equipment for FM Polarity Test (2축 아날로그 태양센서 극성시험장치 개발 및 검증)

  • Park, Young-Woong;Lee, Sang-Sub
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.594-599
    • /
    • 2017
  • In this thesis, the development and the verification of the test-aid are described, providing various attitude errors through the electric stimulus to the Sun sensor. This test-aid for 2-axis analogue Sun sensor is used for polarity test in the assembly stage for GK2 satellite. The test-aid used for GK2 satellite is for COMS satellite and, due to the failure risk, manufactured by domestic company. The characteristics of the COMS test-aid used for GK2 satellite and the manufactured test-aid are showed with similar through the several tests. In this thesis, there are conformed the capability for replacing of test-aid because the characteristics of the manufactured test-aid is acquired same as that of the COMS test-aid using the controller tuning functions.

Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature (온도변화에 따른 $SF_6$ 가스의 절연특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Lee, Kyu-Sun;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures (SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성)

  • Lee, Bok-Hee;Baek, Young-Hwan;Oh, Sung-Kyun;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.85-90
    • /
    • 2006
  • This paper presents experimental results relating to the preliminary breakdown characteristics in $SF_6/CO_2$ gas mixtures under a highly non-uniform electric field. The impulse pre-breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both the positive and negative polarities were fundamentally same. The first streamer corona was initiated at the tip of needle electrode, and the leaders developed with a stepwise propagation and bridged the test gap. The pause time of leader pulses in the positive polarity was significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity. The discharge channel path in the positive polarity was zigzag, and the leader channel in the negative polarity was thicker and brighter than that in the positive polarity.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.