• Title/Summary/Keyword: Polarity ratio

Search Result 108, Processing Time 0.024 seconds

The effect of variable polarity on AC pulse Welding for sheet Al metal (알루미늄 박판에 대한 AC 펄스 MIG 용접에서 극성가변의 효과)

  • 공현상;임성룡;김기정;조상명
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.88-91
    • /
    • 2001
  • New type of vehicles made from thin aluminum alloy are under rapid development and some product are already on the market, but when welding sheet metal joint of aluminum alloy, the main problem are burn-through by the high heat input. The purpose of this study, it is to prevent the burn-through and to shallow penetration that AC pulse welding has diminish the penetration and to lower the droplet temperature at Al sheet metal welding. In this study, we observed the bead appearance and whether it was appeared burn through or not , as the variation of the root gap in the lap and butt-joint welding process.

  • PDF

New Fabrication Approach for Low Voltage Driving Electrophoretic Display

  • Park, Young-Mi;Kim, Do-Yun;Cho, Young-Tae;Lee, Yong-Eui;Kim, Chul-Hwan;Yoon, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.893-895
    • /
    • 2009
  • In this paper, we described the unique and novel method to prepare two kinds of electro-active particles, black and white particles with different polarity. The surface of the particles was characterized to be uniform and clean by adopting spray dryer as a tool for genesis of particles; neither surfactants nor high dielectric medium like water was employed during particle preparation step. The other purpose of this study is to investigate the factors that contribute high driving voltage of particlebased display like QR-LPD. We extracted parameters interaction between particle and electrode, and between oppositely charged particles. Here we reported an excellent behavior of particle-based display that showed low operating voltage, high contrast ratio as high as 8:1 without scarification of quick response time. By optimizing the particle size, charge per mass, selection of external additive sets, a lower driving voltage as low as 40V for the particles with $10{\mu}m$ volume average diameter was obtained.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF

A Study on the Temperature Measurement Using Optical Emission in Saline Solution Discharge with Pin to Plate Electrodes (염류용액 방전의 온도 측정에 관한 연구)

  • Kim, Joong Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.66-71
    • /
    • 2016
  • In this study, electrical and spectroscopic characteristics were investigated in the pin to plate discharge of 0.9% weight per unit volume saline solution. The positive and positive- and negative-going dc pulse with 5% duty ratio were applied to tungsten pin electrode. The more amount of discharge current flew in negative discharge. The temperature, which is considered as a local value in the vicinity of vapor of discharge, was about 3,000K which is much higher than the value recommended to be controlled. It can be suggested that not only the temperature of liquid but also the local temperature of vapor is monitored to investigate damages on tissue or cells in biological application.

Dual Capillary Column System for the Qualitative Gas Chromatography: 1. Comparison Between Split and Splitless Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.1
    • /
    • pp.87-92
    • /
    • 1991
  • A dual capillary column system is described for the simultaneous measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701. Both capillary columns were connected to a common splitless injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter, the dead volume effect of which was found to be negligible. RI and AR were measured with high reproducibility(${\leq}$0.05% RSD) and with high accuracy (<10% RE), respectively. When applied to the test samples of the organic acid mixture, each acid was positively identified by the combined computer RI library search-AR comparison.

Isolation and Physical Properties of Photochemical 8-Methoxypsoralen-thymidine 4$^\prime,5^\prime-C_4$-Monoadducts

  • Shim, Sang-Chul;Kang, Ho-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.6
    • /
    • pp.219-223
    • /
    • 1984
  • The 8-methoxypsoralen$<^{4',5'}_{5',6}>$ thymidine monoadducts are isolated from the irradiation mixture of 8-methoxypsoralen and thymidine in a dry film state by a flash column followed by lobar column chromatography. Some physical properties of the adducts were determined. The fluorescence maximum and quantum yield of the monoadduct are dependent on the solvent polarity and the phosphorescence to fluorescence quantum yield ratio was 2.10 which was significantly increased by external heavy atoms. The phosphorescence lifetime was 1.2s which is relatively large compared to other coumarin derivatives. Accurate spectral data of the monoadducts are presented.

Dual Capillary Column System for the Qualitative Gas Chromatography: 2. Comparison between Splitless and On-Column Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.2
    • /
    • pp.250-255
    • /
    • 1993
  • A dual capillary column system is described for the simultaneous analysis of a given sample and measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701 from a single injection. Both capillary columns were connected to either a splitless injector or an on-column injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter. Both injection modes allowed to measure RI and AR values with high reproducibility (<0.01% RSD) and high accuracy (<10% RE), respectively with the exception that the trace and high boiling solutes required the on-column mode for the accurate quantification and AR comparison. When the dual capillary column system in on-column injection mode was applied to the blind samples containing organic acids, each acid was positively indentified by the combined computer RI library search-AR comparison.

Photophysical properties of Khellin

  • Shim, Sang-Chul;Kang, Ho-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.4
    • /
    • pp.341-344
    • /
    • 1987
  • The fluorescence quantum yield of khellin is sensitive to temperature and to the nature of solvents, especially the proton-donating ability in solute-to-solvent hydrogen bonding. The intersystem crossing quantum yields are 0.4 and 0.15 in acetonitrile and ethanol, respectively. The fluorescence quantum yields in ethanol and isopentane at 77 K are 0.61 and 0.07, respectively, both of which are much larger than the values at room temperature. The phosphorescence lifetime is relatively long and decreases with decreasing solvent polarity. The phosphorescence to fluorescence quantum yield ratio is very small and remains unchanged in various solvents. The results suggest that internal conversion is an important decay channel of the excited singlet state of khellin, especially in the hydrogen-bonding hydroxyl solvents.

Multi-layered Gap Measurement on In-Vessel Cerium Retention Using Ultrasonic Wave Reflective Pattern Analysis and Frequency Diversity Signal Processing (초음파 반사 패턴과 주파수 대역 분할 신호처리를 이용한 다층구조인 노내 간극 측정)

  • Koo, Kil-Mo;Sim, Cheul-Mu;Kim, Jong-Hwan;Kim, Sang-Baik;Kim, Hee-Dong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • A gap between a $Al_2O_3/Fe$ thermite and lower head vessel is formed in the lower-plenum arrested vessel attack(LAVA) experiment which is the 1st phase study of simulation of naturally arrested vessel attack in vessel(SONATA-IV). The gap measurement using a conventional ultrasonic method would be lack of a reliability due to the structure complexity and the metallurgical grain size change of the lower head HAZ occurred by a thermite $Al_2O_3/Fe$ melt or a $Al_2O_3$ melt at $2300^{\circ}C$. The grain echoes having false signals and lower S/N ratio signals are detected due to a multiple scattering, a mode conversion and an attenuation of a ultrasonic resulted from at the interface of increased grain size zone. In this test, the signals pattern was classified to understand the behavior of the ultrasonic in a multi-layer specimen of solid-liquid-solid of assuming that the thermite and the lower head vessel is immersed. The polarity threshold algorithm of frequency diversity gives us the enhancement about 6dB of the ratio S/N.

  • PDF

Constructing an Evaluation Set for Korean Sentiment Analysis Systems Incorporating the Category and the Strength of Sentiment (감성 강도를 고려한 감성 분석 평가집합 구축)

  • Kim, Do-Yeon;Wu, Yong;Park, Hyuk-Ro
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.11
    • /
    • pp.30-38
    • /
    • 2012
  • Sentiment analysis is concerned with extracting and analyzing different kinds of user sentiment expressed in a variety of social media such as blog and twitter. Although sentiment analysis techniques are actively studied for these days, evaluation sets are not developed yet for Korean sentiment analysis. In this paper, we constructed an evaluation set for Korean sentiment analysis. To evaluate sentiment analysis systems more throughly, each sentence in our evaluation set is tagged with the polarity of the sentiment as well as the category and the strength of the sentiment. We divide kinds of sentiment into 7 positive categories and 15 negative categories. Each category is given the strength of the sentiment from 1 to 3. Our evaluation set consists of 3,270 sentences extracted from various social media. For each sentence, 5 human taggers assigned the category and the strength of the sentiment expressed in the sentence. The ratio of inter-taggers agreement was 93% in the polarity, 70% in the category, 58% in the strength of sentiment. The ratio of inter-taggers agreement our evaluation set is a bit higher than other evaluation sets developed for German and Spanish. This result shows our evaluation set can be used as a reliable resource for the evaluation of sentiment analysis systems.