• Title/Summary/Keyword: Point-to-Point Control

Search Result 6,694, Processing Time 0.03 seconds

Suggestion and Implementation of Improved Control Point for Remote Control Home-Network based on the UPnP (UPnP 기반의 홈-네트워크 원격제어를 위한 개선된 Control Point의 제안 및 구현)

  • Jeong, Jin-Gyu;Jin, Seon-Il;An, Gwang-Hyeok;Yu, Yeong-Dong;Hong, Seok-Gyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.769-772
    • /
    • 2003
  • Middleware enables different networking devices and protocols to inter-operate in ubiquitous home network environments. The UPnP(Universal Plug and Play) middleware, which runs on a PC and is based on the IPv4 protocol, has attracted much interest in the field of home network research since it has versatility. The UPnP, however, cannot be easily accessed via the public Internet since the UPnP devices that provide services and the Control Points that control the devices are configured with non-routable local private or Auto IP networks. The critical question is how to access UPnP network via the public Internet. The purpose of this study is to deal with the non-routability problem in local private and Auto IP networks by improving the conventional Control Point used in UPnP middleware-based home networks. For this purpose, this paper proposes an improved Control Point for accessing and controlling the home network from remote sites via the public Internet, by adding a web server to the conventional Control Point. The improved Control Point is implemented in an embedded GNU/Linux system running on an ARM9 platform.

  • PDF

The Efficiency Analysis of using NFC Cadastral Control Point and a Cadastral Information Application (NFC 지적기준점과 지적정보어플리케이션 적용에 대한 효용성 분석)

  • Kim, Sung Jun;Lee, Jong Dal;Kim, Sung Hun;Bae, Jae Yeol
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • The trend of information service and its utilization has been gradually evolving due to the technological breakthrough in IT industries and the spread of smart phones. Especially regarding smart phones, a vast array of applications are being developed and employed for the purpose of providing real time information. Recently, numerous studies have been made and applied in regards to the efficient management and the supply of cadastral control point information. This research has developed and applied the NFC Cadastral Control Point, an advanced version of QR code Cadastral Control Point, which is installed and utilized in Dong-gu Ulsan, Korea, and an application that can utilize both the QR code and the NFC. In addition, this research continues on to analyzing the utility of the two methods that the survey use of a General Cadastral Control Point and the NFC Cadastral Control Point. Having implemented both methods, NFC Cadastral Control Point outweighed its counterpart in terms of the damage it gets from the outside influence and availability. Moreover, through developing Cadastral Control Point that could apply both the QR code Cadastral Control Point and NFC Cadastral Control Point, the research saw tremendous improvements compared to the survey method using the previously existing reference point performance. The results conveyed the fact that cadastral information application was time saving, convenient, and efficient in terms of finding information. Henceforth, with government's administration over Cadastral Control Point and with the development of more application for providing information, a nation-wide monitoring of Cadastral Control Point is considered possible and an efficient usage of information service is expected as well.

A Proposal of Point - to - Point Optimal Control Mode (점간(点間) 위치(位置) 최적제어(最適制御) 방식(方式)의 제안(制案))

  • Kim, Joo-Hong;Eom, Ki-Hwan;Cho, Han-Jun;Oh, Jun-Nam;Kim, Jin-Wan
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.72-75
    • /
    • 1988
  • In the point-to-point motion on servo system, the control mode which minimizes the performance index including, the impact of end point, time and energy, is proposed. The proposed control mode applied to the feed-back control system of D.C motor and then had a computer simulation. This control mode had less the impact of end point, stedy state error, time and energy than the bang-bang or the saturating- proportional control mode.

  • PDF

A Novel Modulation Method for Three-Level Inverter Neutral Point Potential Oscillation Elimination

  • Yao, Yuan;Kang, Longyun;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.445-455
    • /
    • 2018
  • A novel algorithm is proposed to regulate the neutral point potential in neutral point clamped three-level inverters. Oscillations of the neutral point potential and an unbalanced dc-link voltage cause distortions of the output voltage. Large capacitors, which make the application costly and bulky, are needed to eliminate oscillations. Thus, the algorithm proposed in this paper utilizes the finite-control-set model predictive control and the multistage medium vector to solve these issues. The proposed strategy consists of a two-step prediction and a cost function to evaluate the selected multistage medium vector. Unlike the virtual vector method, the multistage medium vector is a mixture of the virtual vector and the original vector. In addition, its amplitude is variable. The neutral point current generated by it can be used to adjust the neutral point potential. When compared with the virtual vector method, the multistage medium vector contributes to decreasing the regulation time when the modulation index is high. The vectors are rearranged to cope with the variable switching frequency of the model predictive control. Simulation and experimental results verify the validity of the proposed strategy.

The effect of Harmonic Distortion Reduction on Three Phase Three level Inverter Using Neutral Point Control (3상 3레벨 인버터의 중성점 제어를 이용한 고조파 왜율 저감 효과)

  • Kim, Jeong Gyu;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.90-94
    • /
    • 2018
  • In this paper, we applied a three-level T-type inverter with the one more voltage level than two-level inverter. However, the three-level T-type inverter has a systematic problem with voltage unbalances. So neutral point control is essential. Therefore, the voltage unbalance problem of the three - phase inverter was confirmed to be controlled within 5V using the neutral point control algorithm in charge and discharge mode. In addition, total harmonic distortion was reduced in three phases (u phase, v phase, w phase) when neutral point control was performed in charging mode and also in three phases (u phase, v phase, w phase) in discharge mode. In this paper suggests a neutral point control algorithm to solve the voltage unbalance of a three-level T-type inverter, and shows the improvement of the performance of the proposed algorithm through experiment.

A Derivation of the Equilibrium Point for a Controller of a Wheeled Inverted Pendulum with Changing Its Center of Gravity (무게중심이 변동되는 차륜형 역진자의 평형점 상태에 관한 연구)

  • Lee, Se-Han
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.5
    • /
    • pp.496-501
    • /
    • 2012
  • An equilibrium point of a WIP (Wheeled Inverted Pendulum) with changing its center of gravity is derived and validated by various numerical simulations. Generally, the WIP has two equilibrium points which are unstable and stable one. The unstable one is interested in this study. To keep the WIP over the unstable equilibrium point, the WIP is consistently being adjusted. A state feedback controller for the WIP needs a control reference for the equilibrium point. The control reference can be obtained by studying an equilibrium point of the WIP based on statics. By using Lagrange method, this study is deriving dynamic equations of the WIP both with and without changing its center of gravity. Various numerical simulations are carried out to show the validation of the equilibrium point.

Extraction of Ground Control Point (GCP) from SAR Image

  • Hong, S.H.;Lee, S.K.;Won, J.S.;Jung, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1058-1060
    • /
    • 2003
  • A ground control point (GCP) is a point on the surface of Earth where image coord inates and map coordinates can be identified. The GCP is useful for the geometric correction of systematic and unsystematic errors usually contained in a remotely sensed data. Especially in case of synthetic aperture radar (SAR) data, it has serious geometric distortions caused by inherent side looking geometry. In addition, SAR images are usually severely corrupted by speckle noises so that it is difficult to identify ground control points. We developed a ground point extraction algorithm that has an improved capability. An application of radargrammetry to Daejon area in Korea was studied to acquire the geometric information. For the ground control point extraction algorithm, an ERS SAR data with precise Delft orbit information and rough digital elevation model (DEM) were used. We analyze the accuracy of the results from our algorithm by using digital map and GPS survey data.

  • PDF

The control of point and non-point source nitrogen to prevent eutrophication of the Nakdong River basin, Korea

  • Kwak, Sunggue;Yun, Zuwhan
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.345-351
    • /
    • 2020
  • Eutrophication of surface waters is commonly caused by excessive inputs of nutrients such as nitrogen and phosphorus. Nakdong River basin was chosen as the study area to investigate the effect of point and non-point source pollution of nitrogen on eutrophication in water body. Non-point source inputs of nitrogen accounted for approximately 84% in the total nitrogen input of the upper Nakdong river watershed, which mainly consists of agricultural land and forests. However, point source inputs of nitrogen accounted for 58~85% in the total nitrogen input of the middle and lower watersheds, including urban area. Therefore, for watershed near urban area, control of point source inputs of nitrogen may be an optimal method to control eutrophication. In this respect, the enforcing reduction of nitrogen in the final effluent of wastewater treatment facilities is needed. On the other hand, to enact more stringent nitrogen regulations, the LOT (limit of technology) and environmental impact should be considered. In this study nitrogen data were analyzed to propose new nitrogen regulations.

A Real Time Quadrotor Autonomous Navigation and Remote Control Method (실시간 쿼드로터 자율주행과 원격제어 기법)

  • Son, Byung-Rak;Kang, Seok-Min;Lee, Hyun;Lee, Dong-Ha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.4
    • /
    • pp.205-212
    • /
    • 2013
  • In recent, the demand of Unmanned Aerial Vehicles (UAVs) that can autonomous navigation and remote control has been increased in military, civil and commercial field. Particularly, existing researches focused on autonomous navigation method based on vanish point and remote control method based on event processing in indoor environments. However, the existing methods have some problems. For instance, a detected vanish point in intersection point has too much detection errors. In addition, the delay is increased in existing remote control system for processing images in real time. Thus, we propose improved vanish point algorithm by removing detection errors in intersection point. We also develop a remote control system with android platform by separating flying control and image process. Finally, we compare the proposed methods with existing methods to show the improvement of our approaches.

Test Point Insertion with Control Point by Greater Use of Existing Functional Flip-Flops

  • Yang, Joon-Sung;Touba, Nur A.
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.942-952
    • /
    • 2014
  • This paper presents a novel test point insertion (TPI) method for a pseudo-random built-in self-test (BIST) to reduce the area overhead. Recently, a new TPI method for BISTs was proposed that tries to use functional flip-flops to drive control test points instead of adding extra dedicated flip-flops for driving control points. The replacement rule used in a previous work has limitations preventing some dedicated flip-flops from being replaced by functional flip-flops. This paper proposes a logic cone analysis-based TPI approach to overcome the limitations. Logic cone analysis is performed to find candidate functional flop-flops for replacing dedicated flip-flops. Experimental results indicate that the proposed method reduces the test point area overhead significantly with minimal loss of testability by replacing the dedicated flip-flops.