A Study on Local Landscape Image of Barn Architecture (축산시설의 지역경관적 이미지에 관한 연구)

  • Chong, Geon Chai;Kim, Gapdeug
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.2
    • /
    • pp.55-62
    • /
    • 2016
  • The goal of this study is to recreate the identification of landscape image through the Agricultural Architecture in rural area. Most of them are not kept with houses in traditional village and the other structures in garden area of Korea, because they are located in the isolated field or placed near along the local street, are designed as a very heavily designed building, and are covered by different materials and color against village architecture. I researched cattle barns in both Korea and Germany of what they have had images in a distance-view points of local area, so that I might find a suitable image of Barn Architecture with topography of rural areas. I surveyed rural agricultural buildings with different point of views on landscape structure, architectural form and materials, and conditions animal welfare. There are three results from this paper as follows: First, the placement of animal barn in garden area is isolated to village so that it may keep a clean environment of village, which it makes non appropriate to land using and village view. Second, the architectural form makes a different image to the village building, because it has an oversize against houses in village or has no rhythm and dividing form of simple gable barm. Third, the barn architecture is better to consider of eco-friendly materials with animal welfare concept design, when it starts to design the barn in the field.

HORIZONTAL AUGMENTATION WITH AUTOGENOUS BLOCK BONE AND IMPLANT PLACEMENT (자가 블록골을 이용한 치조골수평증강술과 임프란트 식립)

  • Ahn, Ji-Yeon;Kim, Young-Kyun;Yun, Pil-Young;Hwang, Jung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.5
    • /
    • pp.444-450
    • /
    • 2007
  • In general, labiolingual or buccolingual widths of residual alveolar bone are insufficient in edentulous area, because of alveolar resorption. Horizontal augmentation is bone graft procedure with a view to reinforcing horizontally insufficient bone quantity for installation of implants. The standard method is taking appropriate amount of block bone from intraoral or extraoral autogenous bone, and solid fixation with screws or mini-plate on labial or buccal side of residual alveolar bone. The purpose of this study is to discuss clinical usefulness of horizontal augmentation with autogenous block bone by observation and analysis of course of 41 implants installed to 12 patients by horizontal augmentation in Seoul National University Bundang Hospital from July, 2002 to December, 2005. The mean age of patients is 52.7, from 19 to 70, and the number of men and women is each 2 and 10. Block bone was taken from symphysis, body, ramus of mandible or iliac bone. And 6 types of implants were installed simultaneously or not, the diameters of implants are from 3.3 to 5.5mm, the lengths are from 8 to 15mm. The operator added artificial bone grafting material and optionally covered with membrane. The mean periods of observation after operation and final prosthetics were 28.6 and 17.0 months. As a result, 40 among 41 implants survived, the survival rate was 97.6%. Average 0.9mm crestal resorption was observed at final point of time by periapical view of each patients. Major complication related to the procedure was numbness in 7 patients.

Job Satisfaction and Marital Satisfaction among married Employers (유배우 근로자의 직업만족도와 결혼만족도)

  • Park, Eun-Ok
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.3
    • /
    • pp.661-669
    • /
    • 2001
  • Purpose: This study was carried out to investigate the difference in job satisfaction and marital satisfaction by gender and to explore the influences of demographic status. employment characteristics. and job satisfaction/marital satisfaction on each type of satisfaction. Method: Social statistics survey data collected by National Statistical Office in 1998 were used for the secondary analysis in the study. Job satisfaction was measured by questionnaires, which consisted of 12 items such as task, promotion, placement, wage, benefits, future in the work, working environment, human relationship. and working hours. And marital satisfaction was collected by questionnaires which consisted of 7 items, including satisfaction with general family life, relationship with their own parent and parent-in-law, relationship with brothers and sisters, relationship with their children, and economic living status. These are measured by 5-point Likert scale. Result: The results show that more than 60% of women were working as part-time employees. Their education levels were lower than men. Men were satisfied significantly more in their jobs than women. Men also had higher marital satisfaction. The employment status had the most important factor on the job satisfaction. and the marital satisfaction was the second important factor among women and men. As for the age, while older men showed higher job satisfaction, younger women showed higher job satisfaction, 28.04% of the variance in the job satisfaction for men and 33.86% for women were accounted for by the following variables: the younger age. the higher education. job satisfaction, and the higher marital satisfaction, 22.15% of the variance in the marital satisfaction for men and 21.19% for women were accounted for by these variables. Conclusion: The results of this study showed that there were differences in job satisfaction and marital satisfaction between genders, and that job satisfaction and marital satisfaction influenced each other. Employment status was the most predictive factor on the job satisfaction. Married women had an unstable employment status such as part-time position. The stability of employment could be considered as a strategy for enhancing job satisfaction for both sexes. The reason that women had lower marital satisfaction than men will have to be further investigated.

  • PDF

THE INFLUENCING FACTORS OF $PERIOTEST^(R)$ VALUE AND IMPLANT STABILITY QUOTIENT ($Periotest^(R)$ Value와 Implant Stability Quotient에 영향을 미치는 요소)

  • Yi Young-Ah;Cha In-Ho;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.40-50
    • /
    • 2006
  • Statement of problem: $Periotest^(R)\;and\;Osstell^{TM}$ were known as the most objective and quantitative mobility tests available for evaluating stability of implant in vivo. Although a correlation between PTV widely used and ISQ recently introduced exist, a PTV was corresponded to various ISQ. A correct evaluation of implant stability could be obtained only after one has a thorough understanding of the limitations of devices and factors that affect measurements. Purpose: The purpose of this study was to investigate the causes of variables in the values obtained with these two tests. Material and method: A total of 333 implants 134 $Br{\aa}nemark$, 5 Silhouette and 194 ITI implants were investigated. Result: 1. There was a correlation between PTV and ISQ (Spearman correlation =0.39, p<0.0001) 2. The factors that affected ISQ were diameter of implant future, location of implant and implant system (submerged type vs non-submerged type). 3. The factors that affected W were dimeter of implant future, location of implant, and elapsed time after implant placement. 4. There was no significant difference between different surface treatments of RBM, smooth surface and ti-unite on PTY and ISQ. 5. In radiographic finding, no saucerization or bone resorption has been detected in implants with ISQ values that were above the average level of each PTV. These higher values had higher bone densities around the implant fixture. Saucerization was observed in the most impants with ISQ values that were below the average level of each PTV. Conclusion: There was a correlation between ISQ and PTV. However, each measuring methods had factors influencing the measured values. PTV were less sensitive to marginal bone resorption and influenced with the striking point on an implant to the level of bone. With ISQ, the height of implant from bone level to transducer should be considered.

LMI Design of Multi-Objective$ Η_2/Η_\infty$Controllers for an Inverted Pendulum on the Cart Using Polytope Models (폴리토프 모델을 이용한 도립진자의 다목적$ Η_2/Η_\infty$ 제어기의 LMI 설계)

  • 이상철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.6-13
    • /
    • 2002
  • This paper deals with the linear matrix inequality (LMI) design procedures for multi-objective Η$_2$$_{\infty}$ controllers with pole-placement constraints for an inverted pendulum system modeled as convex polytopes to ensure the stabilizing regulator and tracking performances. Polytopic models with multiple linear time-invariant models linearized at some operating points are derived to design controllers overcoming the conservativeness such as a controller may have when it is designed for a model linearized at a single operating point. Multi-objective controllers are designed for polytopic models by the LMT design technique with convex algorithms. It is observed that the inverted pendulum controlled by any controller designed for each polytopic model is stabilizingly restored to the vertical angle position for initial values of larger tilt anlges.

Bone regeneration and graft material resorption in extraction sockets grafted with bioactive silica-calcium phosphate composite (SCPC) versus non-grafted sockets: clinical, radiographic, and histological findings

  • Adel-Khattab, Doaa;Afifi, Nermeen S.;el Sadat, Shaimaa M. Abu;Aboul-Fotouh, Mona N.;Tarek, Karim;Horowitz, Robert A.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.418-434
    • /
    • 2020
  • Purpose: The purpose of the present study was to evaluate the effect of silica-calcium phosphate composite (SCPC) granules on bone regeneration in extraction sockets. Methods: Ten patients were selected for a split-model study. In each patient, bone healing in SCPC-grafted and control ungrafted sockets was analyzed through clinical, radiographic, histomorphometric, and immunohistochemical assessments 6 months postoperatively. Results: A radiographic assessment using cone-beam computed tomography showed minimal ridge dimension changes in SCPC-grafted sockets, with 0.39 mm and 1.79 mm decreases in height and width, respectively. Core bone biopsy samples were obtained 6 months post-extraction during implant placement and analyzed. The average percent areas occupied by mature bone, woven bone, and remnant particles in the SCPC-grafted sockets were 41.3%±12%, 20.1%±9.5%, and 5.3%±4.4%, respectively. The percent areas of mature bone and woven bone formed in the control ungrafted sockets at the same time point were 31%±14% and 24.1%±9.4%, respectively. Histochemical and immunohistochemical analyses showed dense mineralized bundles of type I collagen with high osteopontin expression intensity in the grafted sockets. The newly formed bone was well vascularized, with numerous active osteoblasts, Haversian systems, and osteocytes indicating maturation. In contrast, the new bone in the control ungrafted sockets was immature, rich in type III collagen, and had a low osteocyte density. Conclusions: The resorption of SCPC granules in 6 months was coordinated with better new bone formation than was observed in untreated sockets. SCPC is a resorbable bone graft material that enhances bone formation and maturation through its stimulatory effect on bone cell function.

Analysis of the Optimal Location of Wearable Biosensor Arrays for Individual Combat System Considering Both Monitoring Accuracy and Operational Robustness (모니터링 정확도와 운용 강건성을 고려한 개인전투체계용 착용형 생체센서 어레이의 최적 위치 분석)

  • Ha, Seulki;Park, Sangheon;Lim, Hyeoncheol;Baek, Seung Ho;Kim, Do-Kyoung;Yoon, Sang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.287-297
    • /
    • 2019
  • Monitoring for the physiological state of a solider is essential to the realization of individual combat system. Despite all efforts over the last decades, there is no report to point out the optimal location of the wearable biosensors considering both monitoring accuracy and operational robustness. In response, we quantitatively measure body temperature and heartrate from 34 body parts using 2 kinds of biosensor arrays, each of which consists of a thermocouple(TC) sensor and either a photoplethysmography(PPG) sensor or an electrocardiography(ECG) sensor. The optimal location is determined by scoring each body part in terms of signal intensity, convenience in use, placement durability, and activity impedance. The measurement leads to finding the optimal location of wearable biosensor arrays. Thumb and chest are identified as best body parts for TC/PPG sensors and TC/ECG sensors, respectively. The findings will contribute to the successful development of individual combat system.

Development of pre-procedure virtual simulation for challenging interventional procedures: an experimental study with clinical application

  • Seong, Hyunyoung;Yun, Daehun;Yoon, Kyung Seob;Kwak, Ji Soo;Koh, Jae Chul
    • The Korean Journal of Pain
    • /
    • v.35 no.4
    • /
    • pp.403-412
    • /
    • 2022
  • Background: Most pain management techniques for challenging procedures are still performed under the guidance of the C-arm fluoroscope although it is sometimes difficult for even experienced clinicians to understand the modified three-dimensional anatomy as a two-dimensional X-ray image. To overcome these difficulties, the development of a virtual simulator may be helpful. Therefore, in this study, the authors developed a virtual simulator and presented its clinical application cases. Methods: We developed a computer program to simulate the actual environment of the procedure. Computed tomography (CT) Digital Imaging and Communications in Medicine (DICOM) data were used for the simulations. Virtual needle placement was simulated at the most appropriate position for a successful block. Using a virtual C-arm, the authors searched for the position of the C-arm at which the needle was visualized as a point. The positional relationships between the anatomy of the patient and the needle were identified. Results: For the simulations, the CT DICOM data of patients who visited the outpatient clinic was used. When the patients revisited the clinic, images similar to the simulated images were obtained by manipulating the C-arm. Transforaminal epidural injection, which was difficult to perform due to severe spinal deformity, and the challenging procedures of the superior hypogastric plexus block and Gasserian ganglion block, were successfully performed with the help of the simulation. Conclusions: We created a pre-procedural virtual simulation and demonstrated its successful application in patients who are expected to undergo challenging procedures.

Percutaneous Dilatational Tracheostomy in a Cardiac Surgical Intensive Care Unit: A Single-Center Experience

  • Vignesh Vudatha;Yahya Alwatari;George Ibrahim;Tayler Jacobs;Kyle Alexander;Carlos Puig-Gilbert;Walker Julliard;Rachit Dilip Shah
    • Journal of Chest Surgery
    • /
    • v.56 no.5
    • /
    • pp.346-352
    • /
    • 2023
  • Background: A significant proportion of cardiac surgery intensive care unit (CSICU) patients require long-term ventilation, necessitating tracheostomy placement. The goal of this study was to evaluate the long-term postoperative outcomes and complications associated with percutaneous dilatational tracheostomy (PDT) in CSICU patients. Methods: All patients undergoing PDT after cardiac, thoracic, or vascular operations in the CSICU between January 1, 2013 and January 1, 2021 were identified. They were evaluated for mortality, decannulation time, and complications including bleeding, infection, and need for surgical intervention. Multivariable regression models were used to identify predictors of early decannulation and the complication rate. Results: Ninety-three patients were identified for this study (70 [75.3%] male and 23 [24.7%] female). Furthermore, 18.3% of patients had chronic obstructive pulmonary disease (COPD), 21.5% had history of stroke, 7.5% had end-stage renal disease, 33.3% had diabetes, and 59.1% were current smokers. The mean time from PDT to decannulation was 39 days. Roughly one-fifth (20.4%) of patients were on dual antiplatelet therapy and 81.7% had anticoagulation restarted 8 hours post-tracheostomy. Eight complications were noted, including 5 instances of bleeding requiring packing and 1 case of mediastinitis. There were no significant predictors of decannulation prior to discharge. Only COPD was identified as a negative predictor of decannulation at any point in time (hazard ratio, 0.28; 95% confidence interval, 0.08-0.95; p=0.04). Conclusion: Percutaneous tracheostomy is a safe and viable alternative to surgical tracheostomy in cardiac surgery ICU patients. Patients who undergo PDT have a relatively short duration of tracheostomy and do not have major post-procedural complications.

Study of analysis quantification of non-point pollution reduction by applying environmentally friendly agriculture(deep placement) (낙동강수계 친환경농법(심층시비) 적용에 따른 비점오염원 정량화 연구)

  • Seok, Jun Young;Kim, Ji Hoon;Lee, Seung Yoon;Kang, Bo Seung;Lim, Tae Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.443-443
    • /
    • 2021
  • 국내 하천, 호소에 유입되는 오염물질 중 30% 이상이 농업 활동 등으로부터 기인한다. 정부 부처는 '04년부터 농업 비점오염원 저감 대책을 수립·시행하고 있으나 농촌 인구 고령화, 열악한 재정환경, 관행화·고착화 된 농법 등으로 인해 주민참여 및 대책 적용의 한계가 있었다. 금호강 상류 보현산댐 유역은 대부분 임야로 고현천 등 상류 하천변에 사과원이 밀집되어 있다. 또한, 유역면적이 32.16km2로 좁고, 유로 연장 5km 이내로 짧으며 하천 경사가 급해 강우시 토양 유실량이 많고 유출속도가 빠르다. 이러한 유역 특성상 상류 사과원은 '16년 보현산댐 담수 이후 매년 반복적으로 발생하는 녹조 등 수질 문제를 초래하는 주요 비점오염원으로 지역사회 이슈가 되었다. 이에 따라 K-water는 낙동강수계관리위원회 환경기초조사사업의 일환으로 지역주민들과 논의를 통하여 댐 상류 사과원에 친환경농법(심층시비)를 적용하고 수질 개선 효과를 분석하였다. 심층시비는 과수 주변 토양 천공 후 퇴비를 시비하는 친환경농법으로 표층시비에 비해 초기 강우유출 오염물질량을 저감하고 퇴비 사용량도 줄일 수 있다. 금번 연구에서 실제 운영 중인 농지('19년 24천평, '20년 27천평)을 대상으로 심층시비를 시범적용한 결과, 퇴비 사용량은 표층시비의 50% 수준으로 감소하였고 과수 생육 및 품질에는 큰 영향이 없는 것으로 나타났다. 강우 시 유출농도는 표층시비 대비 TOC 5.0~41.3%, T-P 4.0~57.3% 감소했다. HSPF 유역 모델링 분석 결과, 전체 과수원 중 70% 농지에 심층시비를 적용한 경우, 하절기 유역 T-P 유입부하량이 5.0~6.8%(소유역 최대 28.2%) 감소하는 것으로 예측되었다. 본 연구결과를 바탕으로 심층시비를 확대 적용하고 유역 수질관리에 기여하고자 한다.

  • PDF