Study on Model Identification and Pre-Differential 2-DOF PID Flow Control Algorithm for Cooling Processes (냉각 프로세서의 모델규명 및 선행미분형 2 자유도 PID 유량 제어 알고리즘에 관한 연구)

  • Hwang, I-Cheol;Park, Cheol-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1917-1923
    • /
    • 2010
  • This study focuses on model identification and a 2-DOF PID control algorithm for cooling processes; a pneumatic butterfly-type control valve is used for this purpose. The mathematical model is a transfer function composed of a time delay and a second-order delay system. The control valve is identified as a first-order delay system with a time delay and included in the controlled plant. From the experimental data sets for a demo plant, the model parameters are identified, and the 2-DOF PID control gains are analytically derived by Kitamori's method. We show via a computer simulation and an experimental test that the performance of the proposed 2-DOF PID control system is better than that of a conventional 1-DOF PID control system.

Effects on Changes in Femoral Vein Blood Flow Velocity with the Use of Lower Extremity Compression for Critical Patients with Brain injury (하지압박요법이 중증 뇌손상 환자의 대퇴 정맥 혈류 속도변화에 미치는 영향)

  • Kim, Jung-Sook;Kim, Hye-Jung;Woo, Yun-Hee;Lym, Ji-Young;Lee, Chul-Hyung
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.2
    • /
    • pp.288-297
    • /
    • 2009
  • Purpose: This study was done to evaluate the mean venous velocity (MVV) response with knee and thigh length compression stockings (CS) versus intermittent pneumatic compression (IPC) devices in immobile patients with brain injuries. Methods: We carried out a randomized controlled study. We analyzed both legs of a randomly chosen sample of 43 patients assigned to one of 4 groups (86 legs). The patients were sequentially hospitalized in the intensive care unit (ICU) in "S hospital" from November 2005 to December 2006. The base line and augmented venous velocity was measured at the level of the common femoral vein. We applied leg compression 42 times over 7 days (for 2 hours at a time at 2 hour intervals). Results: There was a statistical difference among the 4 groups. The difference for the "IPC" group was more significant than the "CS" group. Conclusion: These results indicate that the application of IPC can be considered as an effective method to prevent deep vein thrombosis for immobile patients with brain injury.

Piezoelectric and electromechanical properties of PZT films and PZT microcantilever (PZT 박막의 압전 특성 및 MEMS 기술로 제작된 PZT cantilever의 전기기계적 물성 평가)

  • 이정훈;황교선;윤기현;김태송
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.177-180
    • /
    • 2002
  • Thickness dependence of crystallographic orientation of diol based sol-gel derived PZT(52/48) films on dielectric and piezoelectric properties was investigated The thickness of each layer by one time spinning was about 0.2 $\mu\textrm{m}$, and crack-free films was successfully deposited on 4 inches Pt/Ti/SiO$_2$/Si substrates by 0.5 mol solutions in the range from 0.2 $\mu\textrm{m}$ to 3.8 $\mu\textrm{m}$. Excellent P-E hysteresis curves were achieved without pores or any defects between interlayers. As the thickness increased , the (111) preferred orientation disappeared from 1$\mu\textrm{m}$ to 3 $\mu\textrm{m}$ region, and the orientation of films became random above 3 $\mu\textrm{m}$. Dielectric constants and longitudinal piezoelectric coefficient d$\_$33/, measured by pneumatic method were saturated around the value of about 1400 and 300 pC/N respectively above the thickness of 0.8 7m. A micromachined piezoelectric cantilever have been fabricated using 0.8 $\mu\textrm{m}$ thickness PZT (52/48) films. PZT films were prepared on Si/SiN$\_$x/SiO$_2$/Ta/Pt substrate and fabricated unimorph cantilever consist of a 0.8 fm thick PZT layer on a SiNx elastic supporting layer, which becomes vibration when ac voltage is applied to the piezoelectric layer. The dielectric constant (at 100 kHz) and remanent polarization of PZT films were 1050 and 25 ${\mu}$C/$\textrm{cm}^2$, respectively. Electromechanical characteristics of the micromachined PZT cantilever in air with 200-600 $\mu\textrm{m}$ lengths are discussed in this presentation.

  • PDF

Biochemical Reactions on a Microfluidic Chip Based on a Precise Fluidic Handling Method at the Nanoliter Scale

  • Lee, Chang-Soo;Lee, Sang-Ho;Kim, Yun-Gon;Choi, Chang-Hyoung;Kim, Yong-Kweon;Kim, Byung-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.2
    • /
    • pp.146-153
    • /
    • 2006
  • A passive microfluidic delivery system using hydrophobic valving and pneumatic control was devised for microfluidic handling on a chip. The microfluidic metering, cutting, transport, and merging of two liquids on the chip were correctly performed. The error range of the accuracy of microfluid metering was below 4% on a 20 nL scale, which showed that microfluid was easily manipulated with the desired volume on a chip. For a study of the feasibility of biochemical reactions on the chip, a single enzymatic reaction, such as ${\beta}-galactosidase$ reaction, was performed. The detection limit of the substrate, i.e. fluorescein $di-{\beta}-galactopyranoside$ (FDG) of the ${\beta}-galactosidase$ (6.7 fM), was about 76 pM. Additionally, multiple biochemical reactions such as in vitro protein synthesis of enhanced green fluorescence protein (EGFP) were successfully demonstrated at the nanoliter scale, which suggests that our microfluidic chip can be applied not only to miniaturization of various biochemical reactions, but also to development of the microfluidic biochemical reaction system requiring a precise nano-scale control.

Variable Passive Compliance Device for Robotic Assembly (조립 로봇용 가변 수동 강성 장치의 설계)

  • Kim, Hwi Su;Park, Dong Il;Park, Chan Hun;Kim, Byung In;Do, Hyun Min;Choi, Tae Yong;Kim, Doo Hyung;Kyung, Jin Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.517-521
    • /
    • 2016
  • General industrial robots are difficult to use for precision assembly because they are operated based on position control. Their position accuracy is also usually higher than the assembly clearance (several tens of ${\mu}m$). In previous researches, force control was suggested as a robotic assembly solution. However, this method is difficult to apply in reality because of speed and cost problems. The RCC provides high speed, but applications are limited because the compliance is fixed, and it cannot detect an assembly condition during a task. A variable passive compliance device (VPCD) was developed herein. The VPCD can detect the assembly condition during tasks. This device can provide proper compliance for successful assembly tasks. The pneumatic system and the Stewart platform with an LVDT sensor were applied for measuring the displacement and variable compliance, respectively. The concept design and analysis were conducted to prove the effectiveness of the developed VPCD.

The Development of the Movable-housing Planning Concept in Housing-architectural history of 20th Century (20 세기 주거건축사에 나타난 이동식 주거개념의 발전과정에 관한 연구)

  • Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.13-21
    • /
    • 2008
  • The purpose of this study is to analyze the development and characteristics of movable-housing planning concept. A document research method was used to analyze and classified the development of the movable-housing concept of 20th century. Through this study, the following conclusions have been reached; First, the origin of the movable-housing is from the prehistoric and traditional portable buildings, also due to the emergence of nomadic lifestyle using car traveling and mobile home in the 1920's. Second, the development of the movable-housing in 20th century was classified as follows; (1) In order to obtain the productivity and efficiency drawing from the industrialized-housing in the early of 1900s, movable furniture and flexibility was proposed. (2) American mobile home in 1920's, influenced by the development of car industry, was the most successful example of a factory-built building to be found in the world. (3) Dymaxion house and dome by R.B.Fuller, an aggregation of high-tech mechanical equipment, had a great impact on the development the concept of 'mobility' and influenced Archigram & Metabolist's movable capsule ideas in 1960's. (4) The lightweight materials such as plastic, duralumin and pneumatic structure were adopted for movable-housing in 1960's. Through this research, It is discovered that the stage of social development has close links with the developing aspects of movable-housing concepts. This study shows that the combination of three planning concepts such as flexible housing, mobile-housing and capsule will be more ideal in movable-housing planning rather than relying on just one type.

KSR- III 추력벡터제어를 위한 유압-서보 김발엔진 구동시스템에 관한 연구

  • Lee, Hee-Joong
    • Aerospace Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.141-146
    • /
    • 2002
  • During dynamic flight by propulsion of rocket engine, in the atmosphere, the attitude control of flight vehicle can be accomplished by the aerodynamic fin actuator. But, in the outer space, the method of TVC(Thrust Vector Control) is only depend on for it. There are many systems which were developed for TVC. In our research, among them we adopted gimbal engine actuation system which could control the vector of thrust by swivelling rocket engine connected by gimbal. There are electro-hydraulic, electro-mechanical and pneumatic system which can be used as gimbal engine actuation system, but the electro-hydraulic system that has high ratio of output power to mass is preferred for the high power system. In this note, we made a mathematical model of the electro-hydraulic gimbal engine actuation system for the TVC of KSR-III in detail and on the base of this model we performed a simulation study. And then, we verified the model by making a comparison between the simulation and the experiments on the real system.

  • PDF

Cryo-Compression Therapy After Elective Spinal Surgery for Pain Management: A Cross-Sectional Study With Historical Control

  • Nabiyev, Vugar Nabi;Ayhan, Selim;Adhikari, Prashant;Cetin, Engin;Palaoglu, Selcuk;Acaroglu, R. Emre
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.348-352
    • /
    • 2018
  • Objective: Postoperative dynamic cryo-compression (DC) therapy has been proposed as a method of reducing pain and the inflammatory response in the early postoperative period after orthopedic joint reconstruction surgery. Our aim was to analyze the analgesic efficacy of DC therapy after adult lumbar spinal surgery. Methods: DC was applied for 30 minutes every 6 hours after surgery. Pain was measured by a visual analogue scale (VAS) in the preoperative period, immediately after surgery, and every 6 hours postoperatively for the first 72 hours of the hospital stay. Patients' pain medication requirements were monitored using the patient-controlled analgesia system and patient charts. Twenty patients who received DC therapy were compared to 20 historical controls who were matched for demographic and surgical variables. Results: In the postanesthesia care unit, the mean VAS back pain score was $5.87{\pm}0.9$ in the DC group and $6.95{\pm}1.0$ (p=0.001) in the control group. The corresponding mean VAS scores for the DC vs. control groups were $3.8{\pm}1.1$ vs. $5.4{\pm}0.7$ (p < 0.001) at 6 hours postoperatively, and $2.7{\pm}0.7$ vs. $6.25{\pm}0.9$ (p<0.001) at discharge, respectively. The cumulative mean analgesic consumption of paracetamol, tenoxicam, and tramadol in the DC group vs. control group was $3,733.3{\pm}562.7mg$ vs. $4,633.3{\pm}693.5mg$ (p<0.005), $53.3{\pm}19.5mg$ vs. $85.3{\pm}33.4mg$ (p<0.005), and $63.3{\pm}83.4mg$ vs. $393.3{\pm}79.9mg$ (p<0.0001), respectively. Conclusion: The results of this study demonstrated a positive association between the use of DC therapy and accelerated improvement in patients during early rehabilitation after adult spine surgery compared to patients who were treated with painkillers only.

The Verification Test of Launch Control System Algorithms Using Automated Verification System (자동화 검증시스템을 이용한 발사관제시스템 알고리즘 검증시험)

  • An, Jae-Chel;Moon, Kyung-Rok;Oh, Il-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.127-137
    • /
    • 2021
  • The launch complex(LC) is composed of various facilities. The launch control system that operates remotely those of LC spends much time and labor for developing and verifying its control algorithms. The verification of algorithms is performed by the software developer entering simulated state values based on the test procedure and checking the output result according to the algorithm flow. These verification processes should be performed repeatedly, thus the human errors are easily occurred. In this paper, an efficient automated verification method with a script test procedure is proposed to minimize human errors and shorten the verification duration. We also present the results of the algorithm verification tests for the cases of the compressed gases supply system and the electro pneumatic panel system of LC.

Orientation, Surface Roughness and Piezoelectric Characteristics of AlN Thin Films with RF Magnetron Sputtering Conditions (RF 마그네트론 스퍼터링 공정 조건에 따른 AlN 박막의 배향성, 표면 거칠기 및 압전 특성에 관한 연구)

  • Bang Jung-Ho;Chang Dong-Hoon;Kang Seong-Jun;Kim Dong-Guk;Yoon Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.4 s.346
    • /
    • pp.1-7
    • /
    • 2006
  • AlN thin films have been fabricated by using RF magnetron sputtering method and their crystal orientations, microstructures and piezoelectric properties have been investigated with variation of the $Ar/N_2$ gas ratio and the substrate temperature. Particularly, when the $Ar/N_2$ gas ratio and the substrate temperature are 10/10 (sccm) and $400^{\circ}C$, respectively, the AlN thin film exhibits the highest (002) orientation. The result of the surface roughness measurement by using AFM shows that the surface roughness becomes better as the partial pressure of $N_2$ increases at the substrate temperature of $400^{\circ}C$ and it becomes the smallest value of 2.1 nm when $Ar/N_2$ is 0/20 (sccm). The AFM measurement also shows that when $Ar/N_2$ is 10/10 (sccm) shows that surface roughness becomes better as the substrate temperature increases from room temperature up to $300^{\circ}C$ and then it becomes worse as the substrate temperature goes up from $300^{\circ}C$. At the substrate temperature of $300^{\circ}C$ and $Ar/N_2$=10/10 (sccm), the surface roughness is 3.036 nm. The piezoelectric constant ($d_{33}$) of AlN thin film is measured by Pneumatic probe method. The measurement shows that the AlN thin film with the highest (002) orientation, fabricated at $Ar/N_2$=10/10 (sccm) and the substrate temperature of $400^{\circ}C$, has the best Piezoelectric constant ($d_{33}$) of 6.01 pC/N.