• 제목/요약/키워드: Plumbing system

검색결과 53건 처리시간 0.025초

A Waterborne Outbreak and Detection of Cryptosporidium Oocysts in Drinking Water of an Older High-Rise Apartment Complex in Seoul

  • Cho, Eun-Joo;Yang, Jin-Young;Lee, Eun-Sook;Kim, Se-Chul;Cha, So-Yang;Kim, Sung-Tek;Lee, Man-Ho;Han, Sun-Hee;Park, Young-Sang
    • Parasites, Hosts and Diseases
    • /
    • 제51권4호
    • /
    • pp.461-466
    • /
    • 2013
  • From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing system of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable virus, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.

Effects of Diverse Water Pipe Materials on Bacterial Communities and Water Quality in the Annular Reactor

  • Jang, Hyun-Jung;Choi, Young-June;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권2호
    • /
    • pp.115-123
    • /
    • 2011
  • To investigate the effects of pipe materials on biofilm accumulation and water quality, an annular reactor with the sample coupons of four pipe materials (steel, copper, stainless steel, and polyvinyl chloride) was operated under hydraulic conditions similar to a real plumbing system for 15 months. The bacterial concentrations were substantially increased in the steel and copper reactors with progression of corrosion, whereas those in stainless steel (STS) and polyvinyl chloride (PVC) reactors were affected mainly by water temperature. The heterotrophic plate count (HPC) of biofilms was about 100 times higher on steel pipe than other pipes throughout the experiment, with the STS pipe showing the lowest bacterial number at the end of the operation. Analysis of the 16S rDNA sequences of 176 cultivated isolates revealed that 66.5% was Proteobacteria and the others included unclassified bacteria, Actinobacteria, and Bacilli. Regardless of the pipe materials, Sphingomonas was the predominant species in all biofilms. PCR-DGGE analysis showed that steel pipe exhibited the highest bacterial diversity among the metallic pipes, and the DGGE profile of biofilm on PVC showed three additional bands not detected from the profiles of the metallic materials. Environmental scanning electron microscopy showed that corrosion level and biofilm accumulation were the least in the STS coupon. These results suggest that the STS pipe is the best material for plumbing systems in terms of the microbiological aspects of water quality.

해외규격과 구조해석을 이용한 KGS FS551 개정안 연구 (Research for KGS FS551 Amendment Using Abroad Code and Structure Simulation)

  • 강병익;김병기;김병덕
    • 한국기계가공학회지
    • /
    • 제18권9호
    • /
    • pp.7-16
    • /
    • 2019
  • According to KGS FS551, the safety of an exposure pipe system should be calculated quantitatively by calculating the stress of exposed piping for thermal expansion. However, many pipe system designs and installation sites are not equipped for this. Therefore, KGS FS551 suggested the use of safe gas by presenting the recommended pipe shape. The shapes of various pipe systems have been derived. However, the recommended shape could not be an absolute evaluation standard. Furthermore, the ongoing debate over standards between a plumbing installer and an inspector is an obstacle to the efficient and safe use of gas. Therefore, the correct pipe system evaluation method is examined in this study, and the safety of the existing exposed pipe system is verified.

종합병원의 환기설비 사례 연구 (A Case Study on the Ventilation System of the General hospital)

  • 정종림
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.

KOMAC RFQ Vacuum System

  • Han, J.M.d;S.H.Jeong;Cho, Y.S.;Park, B.H.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.33-33
    • /
    • 1999
  • The design of a vacuum pumping system for the KOMAC (Korea Multipurpose Accelerator Complex) RFQ(Radio-Frequency Quadrupole) linac is described. [Fig] Resulted from the lost proton beam, gas streaming from the LEBT (Low Energy Beam Transport) and out-gassing from the surfaces of the RFQ cavity and vacuum plumbing, the total gas load will be on the order of 7.2$\times$10-4 Torr-liters/sec, consisting mainly of hydrogen. The system designed to pump on a continual basis with redundancy to ensure that the minimal operating vacuum level of 1.0$\times$10-6 Torr is maintained even under abnormal conditions. Details of the design, performance analysis and the preliminary test results of the cryogenic pumps are presented.

  • PDF

유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구 (The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular)

  • 이창재;임석호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

설비 측면에서 본 물 안 쓰는 소변기의 특성 고찰 (A Study on the Characteristics of Waterless Urinal System)

  • 고무환;서기원;김윤중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2008
  • The most important thing in the restroom is the saving water resource and the removing bad odor. Due to the waste of water and the inefficient operating system, the current urinal receptacles have been gradually replaced by the waterless urinal receptacles in the advanced countries. Therefore, this study investigated the advantages, the characteristics, and the expected problems of the current and the waterless urinal systems. Based on the comparisons between the two urinal systems from this study, the plumbing engineers can positively consider the replacement of the current urinal receptacles with the waterless ones.

  • PDF

원형기둥 콘크리트 구멍손실 단면적의 압축거동에 관한 축소모델 실험적 연구 (Experimental Study on the Behavior of Psudo Circular Concrete Column)

  • 손기상
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.89-98
    • /
    • 2001
  • There have been a lot of studies about repair & strengthening of the concrete structure. But there has almost not been my study on section damage effect due to holes drilled out for installing additional facilities or equipment, such as rack on the wall of building or underground culvert system, plumbing system through the column or wall of it, after being occupied. This study is to find out how much the section loss due to holes will give loss of section strength. We cm determine if we repair or reinforce it completely or not, using strength loss from the hole. Hole size of diameter 3cm, 2cm, lcm, depth of 3cm, 5cm, 10cm, and position of each hole has been considered as variables of this study. It is concluded that section loss 30% results in 53% of strength damage.

  • PDF

무공해 자동차용 수열원 히트펌프 시스템의 난방 성능에 관한 실험적 연구 (An Experimental Study on the Heating Performance of Coolant Heat Source Heat Pump System for Zero Emission Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.57-62
    • /
    • 2014
  • This study presented the feasibility of a coolant heat-source heat pump system as an alternative heating system for electrically driven vehicles. Heat pumps are among the most environmentally friendly and efficient heating technologies in residential buildings. In various countries, electric mobiles devices such as EV, PHEV, and FCEV, have been mainly concerned with heat pumps for new mobile markets. The experiments herein were conducted for various ambient temperatures and coolant temperatures to reflect the winter season. The system, a coolant heat-source heat pump, consisted of an inside heat exchanger, an outside heat exchanger, a motor driven compressor, an electronic expansion valve, and plumbing parts. For the experimental results, the maximum heating capacity and air discharge temperature are up to 6.3 kW and $62^{\circ}C$ respectively at an ambient temperature of $10^{\circ}C$, and coolant at $10^{\circ}C$. However, at $-20^{\circ}C$ ambient temperature and $-10^{\circ}C$ coolant temperature, conditions were insufficient to warm the cabin as the air discharge temperature was $13^{\circ}C$.

대학 시설물 유지관리 서비스 사용자 요청 패턴 분석 (Patterns in User Requests for Facility Management Services in Higher Education Facilities)

  • 엄미영;이강
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2015
  • This paper aims to identify patterns in users' requests for facility management (FM) services in higher education facilities. We analyzed data collected from 309 service request forms, made available via a department office and an enterprise resource planning system, at a private university in Seoul between May 2009 and February 2015. We found that the number of user requests were the highest in September and October. Requests for electronic and communication (E/C) services outnumbered those for architectural services and mechanical and plumbing (M/P) services. Repair requests for doors and windows were the most common under architectural services; repairs for air-conditioners and radiators were the most commonly under M/P services; and installation of electrical outlets, telephone wires, and internet services were the most sought-after E/C services. Maintenance requests were received every three months, while repair requests were received every six or seven months.

  • PDF