• Title/Summary/Keyword: Plumbing noise

Search Result 23, Processing Time 0.019 seconds

An Experimental Study on the Noise Reduction for Toilet Stool Plumbings in Apartment Bathroom (공동주택 욕실의 변기 배수소음 저감에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 2007
  • Recently Among indoor noises plumbing noise from supply and drain water pipe is being pointed out as a annoying noise following to floor impact noise, and it is increasing the rate to point the noise due to the following several reasons: water pressure, vibration by fabricated structures and direct noise propagation from upper floor through ceiling This study aims to analyse the characteristics of toilet stool plumbing noise in apartment bathroom which are generated by crossing plumbings and elbows. And it analyse the effect of noise reduction by soundproofing and insulations which are covered at crossing plumbings. And also analyse the characteristics of noise about a type of elbows, crossing plumbing and result of dB(A). At last it provide a fundamental data for the purpose of reduction of plumbing noise in apartment.

Noise Characteristics of Plumbing System with Wall Hanging Unit (층상배관 배수시스템의 소음 특성 평가)

  • Park, Cheol-Yong;Kim, Sang-Hoon;Jang, Dong-Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1421-1424
    • /
    • 2006
  • Recently Requirement of indoor environment is increased in APT. Among indoor noises of APT, noise of plumbing system in bathroom is very serious problem except of floor impact noise. Plumbing system with wan hanging unit make a good grade and recognition in rating noise of bathroom in grade of house rating. But it is hard to find a data which are measured in APT built. In this study, the effect of noise reduction is checked by measuring the noise of plumbing system with wall hanging unit that is built. As result the upper household's Peak sound level is measured 80dB(A), the under household's peak sound level is measured 40dB(A).

  • PDF

A Study on the Actual Survey and Reduction of Plumbing Noise in Apartment Houses (공동주택 급배수 설비소음의 실태 및 저감방안에 관한 연구)

  • Kim, Heung-Sik;Ji, Yong-Kyoun;Yoon, Se-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.45-54
    • /
    • 1990
  • As the results of actual survey of indoor noise in apartment houses, it represents that plumbing noise and floor impact noise are most unsatisfactory factors to inhabitants. In this paper, the actual condition of plumbing noise in apartment houses was measured and the methods of plumbing noise reduction are suggested. For these suggestions, the actual survey of plumbing noise and the model test on structure-borne sound of water supply pipe and drain sound were carried out.

  • PDF

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

A Study on the Prediction of Plumbing Noise in the Machine Room Using Acoustic Simulation (음향시뮬레이션에 의한 기계실 설비소음의 예측에 관한 연구)

  • Park, Jung-Ho;Han, Kyeong-Yeon;Seo, Jung-Seok;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.335-341
    • /
    • 2004
  • According to the improvements of the education and the cultural level, the noise pollutions which have been occupying a major portion of civil petitions about environment is gradually aggravating. Especially, the plumbing noises which took place at machine room of dormitory are the compositive shapes of an air-borne sounds and a solid-borne sounds. So it has been causing to injure the comfortable residential environment of residents that it is propagated in a residential space. Judging from this point of view, this study grasped the propagation and the properties of attenuation about four varieties's plumbing noise which took place at machine room to understand that it cause influences to a residential space. In this point, we understand the peculiar features by measuring noise, which was generated from equipment in machine rooms of three dormitories having different features. On the basis of these features, we examine all predictability and reliability in comparing the predictive value with the measurable one, using architectural acoustic simulation.

  • PDF

Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment (청감실험을 이용한 건축설비소음의 등급화)

  • You, Hee-Jong;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

Rating of Noise Emission by Plumbing system in Bathroom (화장실 배수관에 따른 배수소음 평가)

  • 정진연;이성호;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.923-927
    • /
    • 2003
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by pipe material, wrapped pipe with glass wool and installed pipe height The characteristics of noise emission from drain-pipes is as follows. The noise reduction pipe in PVC can reduce noise levels in 7-10㏈ and the cast-iron pipe can reduce in 14㏈compared with the normal PVC pipe. In these days, the glass wool was used for preventing the burst and the noise reduction. But the glass wool for wrapping pipe is not effective to the noise reduction. The characteristics of noise emission from various installed pipe height were measured As the ceiling space of the remodeled building was raised, the noise level was troubled by increasing of the vertical pipe length.

  • PDF

A study on development of dry ondol access floor system for sustainable apartment (지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발)

  • Oh, Jin-Kyun;Sohn, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Characteristics of Bathroom Plumbing System Noise in Apartment House (공동주택 욕실 급배수설비 소음특성 -급수압 및 사용수량을 중심으로-)

  • 정광용;이태강;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.277-281
    • /
    • 1994
  • 본 연구에서는 공동주택의 욕실에 설비되어 있는 기기들을 대상으로, 급수압.토수량.배수량 등의 작동조건을 변화시켜가며 그에 따른 발생소음의 특성을 분석.평가하여, 급배수설비소음대책 마련을 위한 기초적인 자료를 제시해보고자 한다.

  • PDF