• Title/Summary/Keyword: Plication

Search Result 116, Processing Time 0.028 seconds

Clinical Study of the Left Atrial Plication in Giant Left Atrium (거대좌심방 환자의 좌심방 봉축술에 대한 임상적 고찰)

  • 김승철
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.92-100
    • /
    • 1987
  • On rare occasions, the left atrium may become extremely large in the mitral valvular disease, showing giant left atrium. The giant left atrium frequently produce compressing effects to the adjacent organs, resulting in the postoperative problems with regard to the hemodynamic and respiratory management. We experienced 13 patients with giant left atrium combined with mitral valvular disease from Oct. 1980 through June 1986. Eleven cases underwent mitral valve replacement with left atrial plication and the other 2 cases were underwent mitral valve replacement without left atrial plication. The follow-up period was 19.3 months in average. There were remarkable postoperative improvements in the chest roentgenogram, echocardiogram, lung function test, NYHA functional class in patients who underwent plication procedure. The postoperative mortality was 9% in plication cases and 50% in non-plication cases.

  • PDF

Correction of Small Eye Opening with Combined Method (복합 안검 성형술을 이용한 작은 눈의 교정)

  • Joh, Se Heum;Lee, Han Earl;Lee, Hae Min
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.187-192
    • /
    • 2008
  • Purpose: Generally speaking, most of Korean have smaller eyes than those of Caucasian and they have epicanthus with narrow palpebral fissure. It makes external appearance looking dull because the length of the palpebral fissure is short and there is a epicanthus. In case the function of the levator muscle is weak, their eyes look much smaller. Epicanthus and weak levator muscle function make the eyes look dull. The above mentioned, authors want to introduce double eyelid operation, epicanthoplasty, levator plication to extend and lengthen the palpebral fissure. Methods: From August 2001 to August 2004, there were 138 cases that had double eyelid operation with epicanthoplasty or levator plication. the 69 cases of them had double eyelid operation and epicanthoplasty, the 33 cases of them had double eyelid operation and levator plication and the 36 cases of them had double eyelid operation and epicanthoplasty and levator plication. Results: After the operation, the length and height of the eyelid are improved remarkably, and most of the patients were satisfied. The length of the eyelid is improved 3 to 5mm($3.4{\pm}0.5mm$) in case of the epicanthoplasty, the width of the eyelid is improved 3 to 4mm($3.1{\pm}0.3mm$) by the levator plication. The length of the eyelid is improved 3 to 5($3.4{\pm}0.4mm$) and the width is improved 2 to 4mm($2.9{\pm}0.5mm$) by the epicanthoplasty used levator plication. Conclusion: The improvement of the eyelid length is almost the same as epicanthoplasty and levator plication are done simultaneously. But the improvement of the eyelid width is less shorter when epicanthoplasty and levator plication are done simultaneously than the case of levator plication alone. This is because there is a tension influencing on the limitation of widening palpebral fissure to fix the epicanthal tendon. This method is recommendable for the patients who want to have much bigger eyes.

Phrenic Nerve Paralysis after Pediatric Cardiovascular Surgery (소아 심혈관수술 후의 횡격막마비)

  • 윤태진
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1542-1549
    • /
    • 1992
  • From March 1986 to August 1992, 18 patients underwent diaphragmatic plication for the diaphragmatic paralyses complicating various pediatric cardiac procedures. Age at operation ranged from 16 day to 84 months with mean age of 11.8 months. In order of decreasing incidence, the primary cardiac procedures included modified Blalock-Taussig shunt [ 5 ], Arterial switch operation [ 4 ], modified Fontan operation [ 2 ], and others [ 7 ]. The suspicious causes of phrenic nerve injury included overzealous pericardial resection [ 7 ], direct trauma during the procedure [ 6 ], dissection of fibrous adhesion around the phrenic nerve [ 3 ] and unknown etiology [ 2 ]. The involved sides of diaphragm were right in 10, left in 7 and bilateral in one. The diagnosis was suspected by the elevation of hem-idiaphragm on chest x-ray and confirmed by fluoroscopy. The interval between primary operation and plication ranged from the day of operation to 38 postoperative days [mean : 14 days]. The method of plication were "Central pleating technique" described by Schwartz in 16 and other techniques in 2. Five patients expired after plication and the cause of death were not thought to be correlated directly with the plication itself. In the remaining 13 survivors, extubation or cessation of positive ventilation could be done between the periods of the day of plication and 14th postoperative days [mean; 3.8day]. We have made the following conclusions : 1] Phrenic nerve paralyses are relatively common complication after pediatric cardiac procedures and the causes of phrenic nerve injury are mostly preventable; 2] Phrenic nerve palsy is associated with corisiderable morbidity; 3] diaphragmatic plication is safe, reliable and can be applicable in patients who are younger age and require prolonged positive pressure ventilation.ntilation.

  • PDF

Surgical Outcomes of Pneumatic Compression Using Carbon Dioxide Gas in Thoracoscopic Diaphragmatic Plication

  • Ahn, Hyo Yeong;Kim, Yeong Dae;I, Hoseok;Cho, Jeong Su;Lee, Jonggeun;Son, Joohyung
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.456-460
    • /
    • 2016
  • Background: Surgical correction needs to be considered when diaphragm eventration leads to impaired ventilation and respiratory muscle fatigue. Plication to sufficiently tense the diaphragm by VATS is not as easy to achieve as plication by open surgery. We used pneumatic compression with carbon dioxide ($CO_2$) gas in thoracoscopic diaphragmatic plication and evaluated feasibility and efficacy. Methods: Eleven patients underwent thoracoscopic diaphragmatic plication between January 2008 and December 2013 in Pusan National University Hospital. Medical records were retrospectively reviewed, and compared between the group using $CO_2$ gas and group without using $CO_2$ gas, for operative time, plication technique, duration of hospital stay, postoperative chest tube drainage, pulmonary spirometry, dyspnea score pre- and postoperation, and postoperative recurrence. Results: The improvement of forced expiratory volume at 1 second in the group using $CO_2$ gas and the group not using $CO_2$ gas was $22.46{\pm}11.27$ and $21.08{\pm}5.39$ (p=0.84). The improvement of forced vital capacity 3 months after surgery was $16.74{\pm}10.18$ (with $CO_2$) and $15.6{\pm}0.89$ (without $CO_2$) (p=0.03). During follow-up ($17{\pm}17$ months), there was no dehiscence in plication site and relapse. No complications or hospital mortalities occurred. Conclusion: Thoracoscopic plication under single lung ventilation using $CO_2$ insufflation could be an effective, safe option to flatten the diaphragm.

Open Transthoracic Plication of the Diaphragm for Unilateral Diaphragmatic Eventration in Infants and Children

  • Alshorbagy, Ashraf;Mubarak, Yasser
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.307-310
    • /
    • 2015
  • Background: To evaluate our experience of early surgical plication for diaphragmatic eventration (DE) in infancy and childhood. Methods: This study evaluated infants and children with symptomatic DE who underwent plication through an open transthoracic approach in our childhood development department between January 2005 and December 2012. Surgical plication was performed in several rows using polypropylene U-stitches with Teflon pledgets. Results: The study included 12 infants and children (7 boys and 5 girls) with symptomatic DE (9 congenital and 3 acquired). Reported symptoms included respiratory distress (91.7%), wheezing (75%), cough (66.7%), and recurrent pneumonia (50%). Preoperative mechanical ventilatory support was required in 41.7% of the patients. The mean length of hospital stay was $6.3{\pm}2.5days$. The mean follow-up period was $24.3{\pm}14.5months$. Preoperative symptoms were immediately relieved after surgery in 83.3% of patients and persisted in 16.7% of patients one year after surgery. All patients survived to the end of the two-year follow-up and none had recurrence of DE. Conclusion: Early diagnosis and surgical plication of the diaphragm for symptomatic congenital or acquired diaphragmatic eventration offers a good clinical outcome with no recurrence.

Usefulness of Muscle Plication and Synthetic Mesh in Breast Reconstruction Using TRAM Pedicled Flap (배곧은근피판을 이용한 유방재건 시 복벽의 주름형성과 합성그물을 이용한 복부성형술의 유용성)

  • Park, Jung Min;Park, Su Seong;Lee, Keun Cheol;Kim, Seok Kwun;Cho, Se Hyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.643-647
    • /
    • 2006
  • Purpose: The transverse rectus abdominis myocutaneous(TRAM) flap has become a mainstay of breast reconstruction. The chief disadvantage of the TRAM flap is its potential to create a weakness in the abdominal wall. Nowadays true hernia is less frequent, but bulging that appears at the muscle donor site, or at the contralateral side, or at the epigastric area is still remained as a problem. To prevent this complications, we have used synthetic mesh as well as abdominal muscle plication. Now we report the result of our methods. Methods: We started to use synthetic mesh and muscle plication as supplementary reinforcement for entire abdominal wall, after TRAM flap harvesting, in an attempt to stabilize it and achieve a superior aesthetic result since 2002. We observed complications of TRAM flap donor site, and compared our results (from January, 2002 to January, 2006) with other operator's result (before 2001) at the same hospital in aspect of incidence of abdominal complications. Results: 42 consecutive patients have been performed routine reinforcement with the extended mesh technique and muscle plication from January, 2002 to January, 2006. Mean patient follow up was 25.2 months. No hernia or mesh related infection were encountered and only one patient had a mild abdominal bulging. Nevertheless the our good results, there were no significant statistical differences were observed between two groups. Conclusion: We recommend the using of synthetic mesh and muscle plication for donor site reconstruction after TRAM flap breast reconstruction to improve strength as well as aesthetic quality of the abdominal wall.

Abdominal Hypertension after Abdominal Plication in Postbariatric Patients: The Consequence in the Postoperative Recovery

  • Martin Morales-Olivera;Erik Hanson-Viana;Armando Rodriguez-Segura;Marco A. Rendon-Medina
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.535-540
    • /
    • 2023
  • Background Abdominoplasty with abdominal plication increases intra-abdominal pressure (IAP) and has been previously associated with limited diaphragmatic excursion and respiratory dysfunctions. Many factors found in abdominoplasties and among postbariatric patients predispose them to a higher occurrence. This study aims to evaluate the impact of abdominal plication among postbariatric patients, assess whether the plication increases their IAP, and analyze how these IAP correlate to their postoperative outcome. Methods This prospective study was performed on all patients who underwent circumferential Fleur-De-Lis abdominoplasty. For this intended study, the IAP was measured by an intravesical minimally invasive approach in three stages: after the initiation of general anesthesia, after a 10-cm abdominal wall plication and skin closure, and 24 hours after the procedure. Results We included 46 patients, of which 41 were female and 5 were male. Before the bariatric procedure, these patients had an average maximum weight of 121.4 kg and an average maximum body mass index of 45.78 kg/m2; 7 were grade I obese patients, 10 were grade II, and 29 were grade III. Only three patients were operated on with a gastric sleeve and 43 with gastric bypass. We presented six patients with transitory intra-abdominal hypertension in the first 24 hours, all of them from the grade I obesity group, the highest presented was 14.3 mm Hg. We presented 15% (7/46) of complication rates, which were only four seroma and five dehiscence; two patients presented both seroma and wound dehiscence. Conclusion Performing a 10-cm abdominal wall plication or greater represents a higher risk for intra-abdominal hypertension, slower general recovery, and possibly higher complication rate in patients who presented a lower degree of obesity (grade I) at the moment of the bariatric surgery.

The Effect of Phrenic Nerve Paralysis After Pediatric Cardiac Surgery on Postoperative Respiratory Care (소아 심혈관 수술 후 발생한 횡격신경마비가 술후 호흡관리에 미치는 영향)

  • 윤태진;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1118-1122
    • /
    • 1996
  • From January 1990 through December 1995, 43 patients underwent diaphragmatic plication for the management of phrenic nerve palsy .complicating various pediatric cardiovascular surgery. Their mean age at plication was 11.1 months and sex ratio was 31 males to 12 females. In order of decreasing incidence, the primary cardiovascular procedures included modified Blalock-Taussig shunt (7), total correction for the Tetralogy of Falloff (7), arterial switch operation (6), unifocalization for the pulmonary atresia with VSD (3), modified Fontan operation (3), VSD patch closure (3) and others. The involved sides of diaphragm were right in 17, left in 2) and bilateral in 3. Extensive pericardial resection with electocauterization of resected margin was thought to be the most common cause of phrenic nerve palsy (20). The interval between primary operation and plication ranged from the day of operation to 98 days (median 11 days). The methods of plication were central pleating technique(plication with phrenic nerve branch preservation) in 41, and other technique In 2. 10 patients died after plication (7: early, 3; late), and the causes of death were thought to be unrelated to plication itself. Among the 36 early survivors, extubation or cessation of positive pressure ventilation could be accomplished between 1 and 24 days postoperatively(mean : 4.5). Cumulative follow-up was 92 patient years without major complications. Postoperative follow-up fluoroscopy was performed in 6 patients, and the location and movement of plicated diaphragms were satisfactory in 5 patients. We concluded that diaphragmatic plication with preservation of phrenic n rve branch could lead to cessation of positive pressure ventilation and complete recovery of diaphragmatic function in the long term, unless the phrenic nerve was irreversibly damaged.

  • PDF

Arthroscopic Reconstruction in Anterior Shoulder Instability - Prospective Comparison of Anteroinferior Plication Versus Inferior Plication - (견관절 전방 불안정성의 관절경하 재건술 - 전하방 관절낭 중첩술과 하방 관절낭 중첩술의 전향적 비교 -)

  • JP, Warner Jon;Ko, Sang-Hun;Jeon, Hyung-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • Purpose: We wanted to evaluate the effectiveness of inferior capsular plication for treating the anterior instability of the shoulder by comparing the prospective outcomes and the incidence of complications of the group (group1) that underwent arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of inferior glenohumeral ligament and the group (group2) that underwent inferior capsular plication that was augmentated by the same method. Materials and Methods: From March 2005 to August 2007, we compared group 1 (42 cases) that underwent arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of the inferior glenohumeral ligament and group 2 (33 cases) that underwent augmentated inferior capsular plication for recurrent anterior instability of the shoulder. The mean age was 22.5 years (range: 17~31 years) in group I, and 21.8 years (range: 16~30 years) in group II. The mean follow up was 23.5 months (range: 12~45 months in group I, and 20.1 months (range: 12~49 months) in group II. We checked the Rowe score and ROM preoperatively and at postoperative 6 months, 1 year and at the last follow up and we compared the incidence of complications. Results: The Rowe score increased from a preoperative mean of 20.6 to the last follow up mean of 86.8 after surgery in group I, and the Rowe score increased from a preoperative mean of 20.5 to the last follow up mean of 94.1 after surgery in group II. For the anterior instability of the shoulder, arthroscopic reconstruction had a good outcome in all of the cases, but group II had better outcomes and less complications than did group I (p<0.05). Conclusion: We thought that arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of the inferior glenohumeral ligament with inferior capsular plication can lower the complication rate and show better outcomes.

The Surgical management of Ebstein's anomaly: A Report of 4 cases of tricuspid valve replacement and plication of the atrialized right ventricle (Ebstein 심기형의 개심술 4례 (삼첨판막 대치이식술 및 우심실 Plication))

  • Im, Seung-Pyeong;Yang, Gi-Min;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.435-441
    • /
    • 1980
  • Ebstein`s anomaly had been amenable to reparative surgery since 1962. However, neither the role of surgery in Ebstein`s anomaly nor the surgical procedure of choice for its correction are clearly defined. Whether or not the atrialized right ventricle, which plays a major role in the functional abnormalities, should be obliterated in all cases remains unsolved. Four cases of Ebstein`s anomaly treated surgically at Seoul National University Hospital were reported. All had closure of the atrial septal defect, obliteration of the atrialized right ventricle by plication, and insertion of a tricuspid bioprosthesis and an epicardial ventricular pacemaker. One patient had a pulmonic valvotomy due to stenotic bicuspid pulmonic valve also. All but one had discharged with a good result.

  • PDF