• Title/Summary/Keyword: Plates

Search Result 6,478, Processing Time 0.029 seconds

Nonlinear resonance of magneto-electro-thermal-elastic plates with geometric imperfection

  • Yin-Ping Li;Gui-Lin She
    • Computers and Concrete
    • /
    • v.34 no.3
    • /
    • pp.267-277
    • /
    • 2024
  • In this article, the primary resonance characteristic of magneto-electro-elastic plates is analyzed, in which the geometric imperfection, thermal effect and shear deformation are taken into account, Applying Hamilton's principle, derivation of nonlinear motion equations is performed. Through solving these equations according to the modified Lindstedt Poincare method, the impacts of external electric voltage, magnetic potential, boundary conditions, temperature changes, geometric imperfection and aspect ratio on the resonance behaviors of MEE plates are examined. It can be found that, as the electric potential rises, the resonance position will be advanced. As the magnetic potential goes up, the resonance frequency of the plates increases, thus delaying the resonance position. As the initial geometric imperfection rises, the resonance position does not change, and the hard spring properties of the plates gradually weaken.

Analysis of the Rrigidity and the Vibration of Flat Corrugated Plates (주름판의 강성해석 및 진동해석)

  • Han, B.K.;Chung, K.;Yoo, S.Y.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 1991
  • Stiffened plate structure, which is generally used in the various structural design to develope the load carrying capacity, is classified in two groups; one is the plate stiffened with stiffeners, the other is corrugated plate. In the studies on those structures, the studies on the stiffened plates with stiffeners have been much studied with both quantities and qualities according to requirements of the minimum-weight structural design and the development in many industrial fields, especially automobile, ship and aerospace fields, but the studies on the corrugated plates are undeveloped in comparison with the stiffened plates, and also the analytical stiffness on the corrugated plates remains as the imperfect. In the present studies, the analytical method on the stiffness of corrugated plates made by folding is proposed, and the stiffness equation of corrugated plates with some angle is derived and generalized. The purpose of the present study is to contribute to the design of corrugated plates and to determine the optimum aspect ratio for parameters that decide the aspect of corrugated plates.

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

The effectiveness of a pre-procedural mouthrinse in reducing bacteria on radiographic phosphor plates

  • Hunter, Allison;Kalathingal, Sajitha;Shrout, Michael;Plummer, Kevin;Looney, Stephen
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.149-154
    • /
    • 2014
  • Purpose: This study assessed the effectiveness of three antimicrobial mouthrinses in reducing microbial growth on photostimulable phosphor (PSP) plates. Materials and Methods: Prior to performing a full-mouth radiographic survey (FMX), subjects were asked to rinse with one of the three test rinses ($Listerine^{(R)}$, $Decapinol^{(R)}$, or chlorhexidine oral rinse 0.12%) or to refrain from rinsing. Four PSP plates were sampled from each FMX through collection into sterile containers upon exiting the scanner. Flame-sterilized forceps were used to transfer the PSP plates onto blood agar plates (5% sheep blood agar). The blood agar plates were incubated at $37^{\circ}C$ for up to 72 h. An environmental control blood agar plate was incubated with each batch. Additionally, for control, 25 gas-sterilized PSP plates were plated onto blood agar and analyzed. Results: The mean number of bacterial colonies per plate was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse negative control groups. Only the chlorhexidine and Listerine groups were significantly different (p=0.005). No growth was observed for the 25 gas-sterilized control plates or the environmental control blood agar plates. Conclusion: The mean number of bacterial colonies was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse groups. Nonetheless, a statistically significant difference was found only in the case of Listerine. Additional research is needed to test whether a higher concentration (0.2%) or longer exposure period (two consecutive 30 s rinse periods) would be helpful in reducing PSP plate contamination further with chlorhexidine.

STABILITY OF MAXILLARY POSITION AFTER LEFORT I OSTEOTOMY USING BIODEGRADABLE PLATES AND SCREWS (생체흡수성 고정장치를 이용한 상악골 이동술 후 장기간 결과)

  • Kim, Bong-Chul;Jung, Young-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.499-503
    • /
    • 2007
  • Introduction: In orthognathic surgery, internal fixation has been usually done with titanium plates and screws. Recently, Biodegradable plates and screws have been frequently used but the reports of long term results of postoperative stability are rare, especially after maxillary reposition in orthognathic surgery. Objective: In order to clarify the clinical utility of self-reinforced bioresorbable poly-70L/30DL-Lactide miniplates & screws in maxillary fixation after LeFort I osteotomy, this study examined the postsurgical changes in maxilla and complications of biodegradable plates and screws. Study design: Nineteen patients who had undergone maxillary internal fixation using biodegradable plates and screws were evaluated radiographically and clinically. A comparison study of the changes in maxilla position after surgery in all 19 patients was performed with 1-week, 1-month, 3-months, 6-months and/or 1-year postoperative lateral cephalograms by tracing. Complication of the biodegradable plates and screws was evaluated by follow-up roentgenograms and clinical observation. And one-way ANOVA test was used for statistical analysis. Results: The position of the maxillary bone was stable after surgery and was not changed significantly from 1 week to 1 year after operation. And we could not find any complication of biodegradable plates and screws. Conclusions: Internal fixation of the maxilla after LeFort I osteotomy using self-reinforced biodegradable plates and screws is a reliable method for maintaining postoperative position of the maxilla after LeFort I osteotomy.

Thermal Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling (로봇 냉각을 위한 수냉식 냉각판의 열적 성능 평가)

  • Karng, Sanrng-Woo;Lee, Suk-Won;Hwang, Kyu-Dae;Kim, Seo-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1864-1869
    • /
    • 2007
  • In this study, we compare thermal performance between four different types of cold plates for humanoid robot cooling. Two commercially available cold plates made of copper have different dimensions and internal flow paths: One has $20{\times}20$ $mm^2$ base area with micro-channels and the other has $62.5{\times}62.5$ $mm^2$ base area with 85 round pin-fins. And two different types of cold plates of $20{\times}20$ $mm^2$ base area with 7 mm high are made of PC (polycarbonate), which aims to reduce the weight of cooling system. All cold plates are mounted on a $20{\times}20$ $mm^2$ copper block with two cartridge heaters of 30 $W/cm^2$. The overall heat transfer coefficient and thermal resistances for the liquid-cooled cold plates are obtained. The copper cold plate with micro-channels showed the best performance. Polycarbonate cold plates display fairly good thermal performance with more reduced system weight.

  • PDF

Contact buckling behaviour of corrugated plates subjected to linearly varying in-plane loads

  • Dong, Jianghui;Ma, Xing;Zhuge, Yan;Mills, Julie E.
    • Steel and Composite Structures
    • /
    • v.29 no.3
    • /
    • pp.333-348
    • /
    • 2018
  • An analytical method is developed for analysing the contact buckling response of infinitely long, thin corrugated plates and flat plates restrained by a Winkler tensionless foundation and subjected to linearly varying in-plane loadings, where the corrugated plates are modelled as orthotropic plates and the flat plates are modelled as isotropic plates. The critical step in the presented method is the explicit expression for the lateral buckling mode function, which is derived through using the energy method. Simply supported and clamped edges conditions on the unloaded edges are considered in this study. The acquired lateral deflection function is applied to the governing buckling equations to eliminate the lateral variable. Considering the boundary conditions and continuity conditions at the border line between the contact and non-contact zones, the buckling coefficients and the corresponding buckling modes are found. The analytical solution to the buckling coefficients is also expressed through a fitted approximate formula in terms of foundation stiffness, which is verified through previous studies and finite element (FE) method.

Experimental Study On Power Flow Analysis of Vibration of Various Coupled Plates (다양한 연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Hwang, S.G.;Kil, H.G.;Lee, G.H.;Lee, J.Y.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.901-904
    • /
    • 2007
  • The power flow analysis (PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiments have been performed to observe the analytical characteristics of the power flow analysis of the vibration of various coupled plates. Those plates include two plates coupled with angles of $90^{\circ}$\;and\;30^{\circ}$, respectively. In the experiment, the loss factor and the input mobility at a source point on each coupled plate have been measured. The data for the loss factors have been used as the input data to predict the vibration of the coupled plates with PFA. The frequency response functions have been measured over the surface of the coupled plates. The comparison between the experimental results and the predicted PFA results for the frequency response functions has been performed.

  • PDF

Use of Buckling Coefficient in Predicting Buckling Load of Plates with and without Holes (홀의 유무에 따른 평판 좌굴하중 산정을 위한 좌굴계수)

  • Behzad, Mohamazadeh;Noh, Hyuk-Chun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • Buckling, a form of failure happened to plated structures, is investigated in this study. The main focus is to investigate the effects of thickness of the plates having through-thickness holes on buckling when the plate is subjected to in-plane compression. Plates having length of 200mm and width of 100mm are chosen to have thickness in range from 0.50mm to 10mm. Two holes of diameters of 20mm are implemented in plates. The finite element procedure using ABAQUS is applied for analyses. Then using the Gerard and Becker equation compressive buckling coefficients, Kc, are calculated and presented to enable engineers to calculate buckling load for the desired plate with holes in specific dimension. In order to generalize the obtained results, verification analysis has been performed by taking plates having different dimensions from the original ones used in this study. The verification showed the capability of buckling coefficients to predict buckling stresses of plates in various dimensions.

Experimental study to evaluate design procedure and proposed improvement measures for clarifier with inclined plates

  • Lee, Byonghi
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.298-305
    • /
    • 2015
  • The Standards for Water Works issued by the Korean government prescribed the insertion of inclined plates in a clarifier to enhance the settling of the suspended solids. In this study, in order to verify the role of the inclined plates, two identical laboratory-scale rectangular clarifiers were constructed and eight inclined plates were inserted into one of the clarifiers and inflow from same source was treated in both the clarifiers. Dye tests revealed that only the front three of the seven slots received the inflow at $0.57m^3/m^2{\cdot}h$, which was the highest SOR (surface overflow rate). Three different SORs, with 12 different SS (suspended solid) concentrations at each overflow rate, were fed to both clarifiers. However, the clarifier with the inclined plates failed to show an improved removal rate for the SS. In order to enable the Boycott effect within the slot, it is suggested that each slot created by the inclined plates receives equalized inflow. Moreover, collision of the inflow with the settled sludge at the bottom of the clarifier has to be avoided. These provisions, which can maximize the Boycott effect, should be added to the Standards for Water Works endorsed by Korean government.