• 제목/요약/키워드: Plate load test

검색결과 587건 처리시간 0.023초

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate

  • Song, Yo-Jin;Jung, Hong-Ju;Park, Hyun-Ho;Lee, Hak-Young;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.571-578
    • /
    • 2014
  • As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 2: verification

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.735-751
    • /
    • 2014
  • In the previous paper, authors proposed the unified equivalent frame method (UEFM) for the lateral behavior analysis of the flat plate structure subjected to the combined gravity and lateral loads, in which the rotations of torsional members were distributed to the equivalent column and the equivalent slab according to the relative ratio of gravity and lateral loads. In this paper, the lateral behavior of the multi-span flat plate structures under various levels of combined gravity and lateral loads were analyzed by the proposed UEFM, which were compared with test results as well as those estimated by existing models. In addition, to consider the stiffness degradation of the flat plate system after cracking, the stiffness reduction factors for torsional members were derived from the test results of the interior and exterior slab-column connection specimens, based on which the simplified nonlinear push-over analysis method for flat plate structures was proposed. The simplified nonlinear analysis method provided good agreements with test results and is considered to be very useful for the practical design of the flat plate structures under the combined gravity and lateral loads.

지반의 교란을 최소화 한 원위치시험법 개발 및 적용 : 스크류재하시험 (Low-Soil Disturbance In-Situ Test Method Development and Its Application : Screw Plate Loading Test)

  • 이용수;황웅기;최용규;김태형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.977-986
    • /
    • 2009
  • Sampling disturbance can introduce considerable errors in the laboratory estimation of geotechnical properties of soils, and the results obtained from sophisticated sampling and careful laboratory testing are not matching with field behavior. Therefore, it is advantage to adopt in-situ testing techniques for the estimation of geotechnical parameters. Therefore, Screw plate loading test, one of new field test technologies, has been investigated in this study. This test can be utilized to find out important properties of soils such as load-displacement, elastic modulus, and shear strength. The screw plate loading test modified from the plate loading test is an experiment underneath ground by inserting a spiral type of auger screw. The structure and characteristics of the screw plate loading test device was examined in detail. In addition, The new screw plate loading test device was manufactured to refer the previous studies. The reliability of developing screw plate loading test was examined through the analysis of the laboratory test.

  • PDF

원자로용 하단고정체에 대한 구조시험 평가 (Evaluation of Structural Test for Bottom End Piece Used for Nuclear Power Reactor)

  • 김재훈;사정우;김덕회;손동성;임정식
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.3-11
    • /
    • 1999
  • The atomic fuel rods between top and bottom end pieces of reactor need to be extended for high combustion rate of future-type fuel to increase the irradiation in the axial direction. For allowing axial extension of the fuel rods, the space between top and bottom end pieces should be expanded. Thus the thickness reduction of the flow plate is necessary. This study was carried out the mechanical strength test by using strain gages as a function of flow plate thickness, the existence of skirt and loading condition for the Korean Fuel Assembly(KOFA). The experimental apparatus was designed for load conditions, uniformly distributed load and displacement. Test method using whiffle tree of uniformly distributed load has been comparatively conservative. The test results were compared with those of finite element analysis and the test method on bottom end piece was established.

  • PDF

대형 평판재하시험을 통한 PF 공법의 하중전이 특성 분석 (Evaluation of Bearing Capacity and Load Transfer Characteristics of Point Foundation(PF) Method through the Large Plate Bearing Test)

  • 강민수;조명수;고용택
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.142-143
    • /
    • 2021
  • The general ground conditions in Korea are distributed in order of fill, deposit soil, weathered soil, weathered rock, soft rock. The fill soil and deposit soil located at the top have relatively low strength compared to the lower layer, and they are sometimes classified as soft ground according to the standard penetration test results. In this study, the PF method, a ground improvement method, was applied to the soft layer, a large plate load test was conducted on the improved ground, and the results were reviewed.

  • PDF

횡방향 가력실험 및 충격실험을 통한 강판콘크리트(SC) 전단벽의 감쇠비 평가 (Investigation of Damping Ratio of Steel Plate Concrete (SC) Shear Wall by Lateral Loading Test & Impact Test)

  • 조성국;소기환;박웅기
    • 한국지진공학회논문집
    • /
    • 제17권2호
    • /
    • pp.79-88
    • /
    • 2013
  • Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.

Behaviour of geocell reinforced soft clay bed subjected to incremental cyclic loading

  • Hegde, A.;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • 제10권4호
    • /
    • pp.405-422
    • /
    • 2016
  • The paper deals with the results of the laboratory cyclic plate load tests performed on the reinforced soft clay beds. The performances of the clay bed reinforced with geocells and geocells with additional basal geogrid cases are compared with the performance of the unreinforced clay beds. From the cyclic plate load test results, the coefficient of elastic uniform compression ($C_u$) was calculated for the different cases. The $C_u$ value was found to increase in the presence of geocell reinforcement. The maximum increase in the $C_u$ value was observed in the case of the clay bed reinforced with the combination of geocell and geogrid. In addition, 3 times increase in the strain modulus, 10 times increase in the bearing capacity, 8 times increase in the stiffness and 90% reduction in the settlement was observed in the presence of the geocell and geogrid. Based on the laboratory test results, a hypothetical case of a prototype foundation subjected to cyclic load was analyzed. The results revealed that the natural frequency of the foundation-soil system increases by 4 times and the amplitude of the vibration reduces by 92% in the presence of the geocells and the geogrids.

이동하중을 받는 판형교의 동적 거동에 대한 실험적 연구 (Experimental Study on Dynamic Responses of Plate-Girder Bridges under Moving Loads)

  • 임성순
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.407-416
    • /
    • 2000
  • 본 연구는 실험적인 방법으로 이동하중을 받는 판형교의 동적 응답을 연구하였다. 판형교의 상부 슬래브는 판요소로, 거더는 보요소로 이상화였다. 이동하중과 판형교는 각각 소규모 차량모델과 교량모델로 제작하였다. 이동 하중을 받는 판형교의 동적 응답은 변형계, 변위계, 가속도계 및 변형도 측정기를 이용하여 측정하였고 측정한 자료로부터 얻은 최대동적응답을 유한요소법의 결과와 비교하였다. 실험적인 모형실험으로 판형교의 동적응답을 얻을 수 있음을 알 수 있다.

  • PDF

Scale Effect를 고려한 기초의 지지력 및 침하량 산정을 위한 모형실험 (Model Tests on the Bearing Capacity and Settlement of Footing Considering Scale Effect)

  • 정형식;김도열;김정호
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.343-354
    • /
    • 2003
  • 재하판과 실제기초의 크기가 상이하므로 평판재하시험으로부터 실제 기초지반의 지지력 및 침하량을 산정할 때, Scale Effect가 고려되어야 한다. 본 논문에서는 5종류의 모형기초지반을 형성하고, 크기가 각각 l0cm, 15cm, 20cm, 25cm인 4가지 크기의 정사각형 평판으로 재하시험을 실시하여 재하판의 크기에 따른 지지력 및 침하 특성을 분석하였다. 또한 분석된 결과를 토대로 하여, 평판재하시험으로부터 실제기초의 지지력 및 침하량을 산정할 때, 모래와 점토의 혼합비율에 따라 Scale Effect를 합리적으로 고려할 수 있도록 식을 제안하였으며, 식에서 지지력 산정계수(a,b)와 침하량 산정계수(c,d)는 모래와 점토의 혼합비율에 따라 구할 수 있도록 그림으로 제시하였다. 지금까지는 현장기초지반에 대한 지지력 및 침하량을 합리적으로 평가할 수 없어 비경제적인 시공이 되어왔으나, 본 연구에서 제안한 지지력 및 침하량 산정방법에서는 모래와 점토의 혼합비율을 고려하여 기초지반의 지지력 및 침하량을 보다 합리적으로 추정할 수 있으므로 기초지반의 안정성 여부에 대한 확신과, 또한 경제적인 시공이 가능할 것으로 판단된다.

사용중 보강되는 부재의 보강설계법 연구 (A Study for Numerical Procedure of Strengthening Capacity in Field)

  • 한만엽;이원창
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.861-866
    • /
    • 1998
  • This study is numerical procedure of strengthening capacity in a field structure and compare analysis data with test data. Recently, many strengthening methods are developed and used to rehabilitate existing structure. However, both theoretical background and applying techniques are not established yet. One of the most popular method is plate bonding method using either steel plate or carbon plate. This theoretical background and applying techniques are very important and those applications are differed when applied in field strengthening cases. Also depending on the analysis out come, displacement increased based n the condition of members while reaching ultimate load or failure load.

  • PDF