• Title/Summary/Keyword: Plate and screw

Search Result 182, Processing Time 0.021 seconds

Improvement of Production Process based on Performance Evaluation System of Unified Heater (통합히터 성능평가장치를 통한 생산 공정 개선)

  • Han, Woo-Hyun;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.114-118
    • /
    • 2014
  • This paper presents improvement of the production process of a unified fuel heater with the help of the performance evaluation system. In order to enhance a starting capability of diesel-engine car, the unified fuel heater is proposed, which consists of main body, upper plate, stopper, lower plate, PTC, screw, bimetal and terminals. In the proposed heater, the sensor is combined with heater body not only to maximize the performance of car but also to reduce the production cost. The performance test chamber is proposed to evaluate the performance of heater. Especially, an effective manufacturing progress for assembling the heater elements can cut down expenses.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Repair of Closed Bilateral Mandibular Fractures Using Bone Plate and Screw in Dogs (개에서 골판을 이용한 비개방성 양측성 하악골절의 수복)

  • 정순욱;한현정;김지선;김준영;정만복
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.138-141
    • /
    • 2003
  • First case, a one-year-old female Shih Tzu weighing 3 kg with closed transverse fractures of bilateral mandibular body between 2nd and 3rd premolar teeth were treated surgically with bone plates and screws, and cranial luxation of temporomandibular joints were reduced to closed method. Second case, a 8.4 years old male Yorkshire terrier weighing 2.6 kg with closed transverse/oblique fractures of bilateral mandibular body between premolar and molar teeth were treated surgically with bone plates and screws. Radiographic examination revealed that the fractures in two cases fixed well and temporomandibular joint was stabilized. One month after operation, jaw activity was excellent and malocclusion wasn't observed.

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.3
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

Weldability of Al 7075 Alloy according to different tools and welding conditions by F.S.W (Al 7075의 마찰교반 용접부 특성에 관한 연구)

  • Jang Seok-Ki;Jeon Jeong-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.30-41
    • /
    • 2006
  • This paper shows mechanical Properties and behaviors of macrostructures for specimens welded by F.S.W according to welding conditions and tool dimensions with $6.35mm_t$ aluminum 7075-T651 alloy plate. It apparently results in defect-free weld zone in case transition speed was changed to 15mm/min 61mm/min and 124mm/min under conditions of tool rotation speed such as 800rpm. 1250rpm and 1600rpm respectively with tool's Pin diameter 40mm and 60mm. The optimum mechanical property, ultimate stress,${\sigma}_Y=470Mpa$ is obtained at the condition of 124mm/min of travel speed with 800rpm of tool rotation speed using full screw type pin. shoulder dia. $20{\phi}mm$ pin dia. $6{\phi}mm$ and pin length 6mm. The full-screw type and the half-screw type pin shows the similar behaviors of weldability. It is found that the size of nugget is depended on tool transition speed and tool dimension by macrostructures of the cross section of weld zone.

Weldability of Al 7075 Alloy according to different tools and welding conditions by F.S.W (Al 7075의 마찰교반 용접부 특성에 관한 연구)

  • Jang, Seok-Ki;Jeon, Jeong-Il
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.348-358
    • /
    • 2005
  • This paper showed mechanical properties and behaviors of macrostructures for specimens welded by F.S.W according to welding conditions and tool with 6.35$mm_t$ aluminum 7075-T651alloy plate. It resulted in defect-free weld zone in case tool rotation speed was 800rpm, 1250rpm and 1600rpm respectively that transition speed was changed to 15mm/min, 61mm/min and 124mm/min with tool's pin diameter 4${\Phi}$mm and 6${\Phi}$mm. The optimum mechanical property, ultimate stress,${\sigma}_Y$=470Mpa was obtained at the condition of 124mm/min of travel speed with 800rpm of tool rotation speed using full screw type pin, shoulder dia. 20${\Phi}$mm, pin dia.6${\Phi}$mm and pin length 6mm. The full-screw type and the half-screw type pin showed the similar behaviors of weldability. It is found that the size of nugget was depended on tool transition speed and tool dimension by macrostructures of the cross section of weld zone.

  • PDF

Treatment of syndesmotic injury of ankle with bioabsorbable screw (생체흡수성 나사못을 이용한 원위경비관절 이개의 치료)

  • Kang, Jae-Do;Kim, Kwang-Ryul;Kim, Hyung-Chun;Lim, Moon-Sup;Kim, Jin-Hyung;Kim, Seong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.88-94
    • /
    • 2003
  • Purpose: Bioabsorbable screws are used to fix the syndesmotic injury of ankle because of no need for additional operation to remove it. The purpose of this study is to assess the efficacy of polylevolactic acid (PLLA) screws of in the treatment of the syndesmotic injury of ankle. Materials and Methods: Eight patients of the syndesmotic injury of ankle with malleolar fracture were evaluated in this study. They were managed with plate and screw fixation for malleolar fracture and polylevolactic acid screw fixation for syndesmotic injury, followed by plaster splinting for 6 weeks. Clinical and radiographic evaluation were done and functional scores were assessed. Results: In all cases, malleolar fractures were healed without problematic widening of syndesmosis. There were no sinus tract formation and no wound complication. Of eight patients, five had excellent results and three had good results. Conclusion: We conclude that polylevolactic acid screw is good material for fixation of the syndesmotic injury of ankle.

  • PDF

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

  • Karakasli, Ahmet;Acar, Nihat;Uzun, Bora
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.180-185
    • /
    • 2018
  • Objective : Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods : Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results : The average pull-out strength values of groups 1A and 1B were $403.78{\pm}11.71N$ and $306.26{\pm}17.55N$, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were $388.73{\pm}17.03N$ and $299.84{\pm}17.52N$, respectively. A statistical significance was detected with p=0.012. Conclusion : The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

RIGID FIXATION BY MINIPLATE IN THE MANDIBULAR SAGITTAL SPLITRAMUS OSTEOTOMY. (하악골 시상골 골절단술시 MINIPLATE에 의한 RIGID FIXATION)

  • Cho, Byoung-Ouck;Lee, Youg-Chan;Yang, Yong-Seog;You, Ha-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.48-54
    • /
    • 1990
  • This is a report of 4 cases of the surgical correction of mandibular prognathism with chief complaint of mastication difficulty, facial asymmetry and protrusive chin. We performed sagittal spit ramus osteotomy for the prognathism, we used the repositioning plate for conserving the condylar segment into its original position and fixed the osteotomized bone segments rigidly with adjustable monocortical plate. Intermaxillary fixation was performed during 2 weeks. As a results, we found the following advantage. 1. Rigid fixation effect like the fixation by the tandem screw. 2. Decreased postoprative swelling. 3. It is needless to do the stab incision for the transbuccal set instrument. 4. It is more convenient to perform the rigid fixation in the monocortical plate method than screw technique.

  • PDF