• 제목/요약/키워드: Plate and screw

검색결과 182건 처리시간 0.02초

무지외반증에서 근위 갈매기형 절골술 후 고정 방법에 따른 차이: K-강선, 유관나사, 금속판 (The Differences of Fixation Method in Proximal Chevron Osteotomy for Hallux Valgus: K-Wire, Cannulated Screw, Plate)

  • 김택선;김학준;박영환;임형태
    • 대한족부족관절학회지
    • /
    • 제15권2호
    • /
    • pp.62-67
    • /
    • 2011
  • Purpose: The authors evaluated the differences between K-wires and Cannulated screw, plate for fixing the proximal metatarsal chevron osteotomy of moderate and severe hallux valgus. Materials and Methods: There were 62 patients (79 feetz) who were moderate and severe degree hallux valgus according to the classification of Mann. They all got the proximal chevron osteotomy when correcting the deformity. We divided the patients into 4 groups, Two K-wire fixed group as A, one cannulated screw fixed group as B. Two cannulated screw fixed group as C, Plate fixed group as D, Group A were patients (26 feet) and Group B were patients z(9 feet), Group C were patients (31 feet) and Group D were patients (13 feet). Preoperative, postoperative and follow-up hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured for each patient. ANOVA test and Student t-test were done for statistical analysis. Results: Mean follow up period was 43.8 months (range: 12~82 months). Preoperative mean IMA was $16.4{\pm}3.5$, $17.7{\pm}11.3$, $17.3{\pm}5.9$ and $16.6{\pm}2.3$ degrees in respectively group A, B, C, D. Immediate postoperative mean IMA was $5.6{\pm}3.4$, $7.3{\pm}4.4$, $7.6{\pm}4.4$ and $6.7{\pm}2.8$ degrees in respectively group A, B, C, D. The final mean IMA was $8.9{\pm}4.5$, $15.2{\pm}7.5$, $10.3{\pm}4.4$ and D $7.7{\pm}3.5$ degrees in respectively group A, B, C, D. There were significant statistical increase in final mean IMA of group B and C (p<0.05). Conclusion: The IMA was significantly increased in the group which used one or two cannulated screw for fixation on follow up, therefore more caution should be needed when using one or two cannulated screw fixation technique after proximal chevron osteotomy.

선저 아연판의 부식에 관한 연구 (A Study on the Corrosion Loss of Zinc Anodes of the Underwater Shell Plate)

  • 김민석;이종문;김종화;강일권;김동수
    • 수산해양교육연구
    • /
    • 제19권1호
    • /
    • pp.129-136
    • /
    • 2007
  • The component parts of the shell plate of a ship are steel. but the screw propeller or the bow thruster is a compound of bronze, nickel and aluminum. On account of the these different components between metals of the shell plate, the screw propeller and the bow thruster, which are underwater, the shell plate of a ship is corroded by the action of ionization. Authors investigated the corrosion loss of the zinc anodes which were attached to the bottom shell of the training ship Kaya for about two years. The obtained results were as follows:1. In case of the shell plate the difference of the corrosion loss according to port and starboard was almost nothing. But the corrosion loss of the forward part was more than that of the aftward part.2. There was little difference in the corrosion loss between the forward and the aftward part on the bilge keel.3. The corrosion loss of the fore, midship and aft part on the false keel were 24.7%, 22.4% and 23.9% respectively.4. The corrosion loss of the fore and the aft part on the false keel was more than that of the midship part.5. The corrosion loss of the bow thruster was greater than any other parts.6. The nearer the zinc anode to the screw propeller the more the corrosion loss on the stern frame, and the situation was also same as on the rudder.

Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures

  • Min, Young-Kyoung;Lee, Seung-Jun;Gwak, Heui-Chul;Kang, Sang-Woo;Suh, Kuen-Tak
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.208-216
    • /
    • 2017
  • Background: This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures. Methods: Seventy-two patients diagnosed with displaced proximal humerus fracture were enrolled for the study. Of these, 50 patients underwent the locking plate surgery with a single calcar screw (plate group), whereas 22 patients underwent the Polarus nail surgery (nail group). The plate group was further divided into plate 1 group (with medial support), and plate 2 group (without medial support). The radiological and functional results of both groups were compared to the nail group. Results: The ${\alpha}$ angle 1 year after surgery was significantly different between plate 1 and plate 2, and plate 2 and nail groups (p=0.041, p=0.043, respectively). The ratio that does not satisfy the reference value of ${\gamma}$ angle was 2.8% in plate 1, 7.1% in plate 2 and 22.7% in nail group (p=0.007); there was a significant difference between plate 1 and nail group, and plate 2 and nail group (p=0.014, p=0.033, respectively). Conclusions: No significant differences were observed in the clinical results between locking plate and Polarus nail. However, in the plate 2 group and nail group, the rate of failure to maintain reduction during the 1-year period after surgery was statistically and significantly higher than the plate 1 group (level of evidence: level IV, case series, treatment study).

악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구 (CLINICAL STUDY OF RESORBABLE PLATE AND SCREW FOR TREATMENT OF MAXILLOFACIAL FRACTURES)

  • 정종철;최세훈;송민석;전창훈;김현민
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권6호
    • /
    • pp.438-443
    • /
    • 2003
  • Purpose : This study evaluated the usefulness of resorbable plate and screw for treatment of maxillofacial bone fractures. Patients and methods : From july, 2000 to july, 2002, we used resorbable plates and screws($Biosorb^{(R)}$ FX, Bionix Inc, Finland) on 126 patients for treatment of maxillofacial bone fractures. Among them, 80 patients were capable of periodic following up to present season. We evaluated these patients with clinical, radiographic findings and subjective satisfaction. Results : 80 patients composed of 63 men and 17 women. Complication rates are 7.5%(6/80) recorded. 1 of bulging sensation, 3 of infection sign, 2 of the plate detachment were shown. The plates involved in such complications were removed. The other patients(92.5%) were not shown any problems. We could not find complete resorption of screw holes in the mandibular symphysis area even though two years later after surgery. Conclusion : Bioresorbable plates and screws are useful as fixation material at maxillofacial fractures although strength is thought to be weaker than titanium plate. But to reduce the possible complicaions, need to careful clinical and radiographical evaluations.

새로운 방식의 나사형 인공디스크 고정체 해석 (Finite Element Analysis of a Newly Designed Screw Type Fixture for an Artificial Intervertebral Disc)

  • 임종완;양현익
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권1호
    • /
    • pp.56-66
    • /
    • 2010
  • The various total replacement artificial discs have developed because spinal fusion has shown a lesser mobility of an operated segment and an accelerated degeneration at adjacent discs. But almost artificial discs have not yet been reached on the substitute surgery of fusion because many problems such as those clinical success rates were not more than them of fusion have not solved. In this paper, vertically inserted assemble-screw fixture in vertebrae was proposed to improve the fixed capability of artificial disc. And also, to evaluate the design suitability of newly designed screw-type, including fixtures of commercial discs such as wedge and plate type, the 1/4 finite element model with a vertebra and various implanted fixtures were generated, and next, 3 bending motions such as flexion, bending and twisting under the moment of 10Nm and compression under the force of 1000N were considered, respectively and finally, FE analyses were performed. Results of three fixture types were compared, such as Range of Motion and maximal stress, and so on. For ROM, the screw type was average 58% less than the wedge type and was average 42% less than the plate type under all loading conditions. For average stress ratio at closer nodes between vertebra and each fixture, the wedge type was the lowest as minimum 0.02 in twisting, screw types were the highest as maximum 0.28 in compression. As the results of using cement material, it was predicted that the instability problem of the wedge type was better solved. The screw type which could be increased by implanting depth according to the number of assembling mid screws, showed that the decreased tendency of ROMs and maximal cancellous bone stresses. In further study, controlling the number of assembling screws that was suitable for a patient's bone quality, development of surgical tools and keeping on design supplementations, which will be able to develop the competitive artificial disc.

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교 (Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures)

  • 이윤태;오현철;윤한국;장재원;장기준
    • 대한족부족관절학회지
    • /
    • 제16권3호
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료 (Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures)

  • 권덕주;이용범;신준
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF

골 접촉 곡선형 금속 고정 시스템 구현 (Implementation of curved type a metallic plate system at the Bone contact)

  • 김정래
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권5호
    • /
    • pp.285-292
    • /
    • 2007
  • 본 논문은 정형외과영역인 대퇴부에 고정하여 사용하는 금속판으로 골 고정 골절치료의 유합술 골절치료를 할 수 있도록 구성하였는데, 사용되는 치료방법은 견고하고, 안정적이며, 역동적인 생물학적 금속판으로 고정 골수강 내 고정술을 적용되도록 견고한 골접촉 곡선형 시스템을 분석하였다. 금속판은 두 가지 유형으로 장형과 단형으로 구성되고, 금속판의 굴곡이 구조적이고 기하학적으로 경성 및 강도가 고루 분포하도록 최적화 하였다. 장 플레이트의 골접촉에 따른 곡선형으로 굽힙강도는 11,000N 이고, 단 플레이트의 골접촉에 따른 곡선형으로 굽힙강도는 6,525N 이며, 금속판에 골편간 압박을 주는 인장강도는 $1573N/m^2,\;1539N/m^2$정도이다. 금속판은 곡선부와 금속판부의 두 가지 부분으로 나뉘어져 있는데, 곡선부만 있는 단형과 밑 부분의 금속판이 달려있는 장형으로 진행되며, 곡선부의 단형은 전체적인 Profile이 낮고, 금속판이 달려있는 장형은 슬리브의 일체형으로 Profile보다 약간 높아져서 있다. 본 논문의 결과로 제공되는 것은 Hip Implant의 Revision case에 있어 보완뿐만 아니라 Hip Neck Fracture 경우에 사용되었던 Compression Hip Screw의 사용이 가능할 것으로 예상된다.

  • PDF

Reconstruction plates used in the surgery for mandibular discontinuity defect

  • Seol, Guk-Jin;Jeon, Eun-Gyu;Lee, Jong-Sung;Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권6호
    • /
    • pp.266-271
    • /
    • 2014
  • Objectives: The purpose of this study was to analyze the survival rate of reconstruction plates that were used to correct mandibular discontinuity defects. Materials and Methods: We analyzed clinical and radiological data of 36 patients. Only discontinuous mandibular defect cases were included in the study. Reconstruction plate survival rate was analyzed according to age, gender, location of defect, defect size, and whether the patient underwent a bone graft procedure, coronoidectomy, and/or postoperative radiation therapy (RT). Results: Plate-related complications developed in 8 patients, 7 of which underwent plate removal. No significant differences were found in plate survival rate according to age, gender, location of defect, defect size, or whether a bone graft procedure was performed. However, there were differences in the plate survival rate that depended on whether the patient underwent coronoidectomy or postoperative RT. In the early stages ($9.25{\pm}5.10months$), plate fracture was the most common complication, but in the later stages ($35.75{\pm}17.00months$), screw loosening was the most common complication. Conclusion: It is important to establish the time-related risk of complications such as plate fracture or screw loosening. Coronoidectomy should be considered in most cases to prevent complications. Postoperative RT can affect the survival rate and hazard rate after a reconstruction plate is fitted.