• Title/Summary/Keyword: Plate and screw

Search Result 182, Processing Time 0.025 seconds

Fine Structure of the Sperm in the Myotis daubentonii ussuriensis (물윗수염박쥐(Myotis daubentinii ussuriensis)의 정자미세구조)

  • Kim, Hyun-Hee;Lee, Jung-Hun
    • Applied Microscopy
    • /
    • v.41 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • The fine structures of the sperm morphology in the Myotis daubentonii ussuriensis were observed by transmission electron microscope. The results showed that the sperm head revealed bullet shaped, the width was showed a slender more than toward the posterior region to anterior region of nucleus. The sperm head was about $4.5{\mu}m$ in length, being about $2.0{\mu}m$ in width. The nuclear length was $4.3{\mu}m$, occupied most of the sperm head. The nucleus and acrosome were separated by the apical body. The neck region was composed the basal plate, capitulum and segmented columns. The segmented columns were about 12 to 14 in number and connected with the outer dense fibers of the middle piece. The mitochondria sheath were arranged like the thread of a screw, and the total number of mitochondrial gyres were 57. The satellite fibers were observed irregularly among the outer dense fibers in the middle piece. Except the middle piece they are not observed in the principal and end pieces of the tail. In general, the tail show axoneme composed of a 9+2 microtubular pattern, and microtubules of the end piece were arranged irregularly.

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Analysis of End-Plated Propellers by Panel Method (패널법에 의한 날개끝판부착 프로펠러의 해석)

  • C.S. Lee;I.S. Moon;Y.G. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.55-63
    • /
    • 1995
  • This paper describes the procedure to analyze the performance of the end-plated propeller(EPP) by a boundary integral method. The screw blade(SB) and end-plate(EP) are represented by a set of quadrilateral panels, where the source and normal dipole of uniform strength are distributed. The perturbation velocity potential, being the only unknown via the potential-based formulation, is determined by satisfying the flow tangency condition on the blade and the end-plate at the same time. The Kutta condition is satisfied through an iterative process by requiring the null pressure jump across the upper and lower sides of the trailing edges of both the SH and the EP. Sample calculations indicate that the EP increases the loading near the tip of the SB while spreading the trailing vortices along the trailing edge of the EP, thus avoiding the strong tip-vortex formation. Predicted performance of the EPP shows good correlations with the experimental results. The method is therefore considered applicable in designing and analyzing the EPP which may be an alternative for energy-saving propulsive devices.

  • PDF

A study on the forming condition of a bone plate made of a glass/polypropylene composite (Twintex) (유리섬유/폴리프로필렌 복합재료 (Twintex)를 이용한 고정판 성형조건에 관한 연구)

  • Park, Seok-Won;Yoo, Seong-Hwan;Lee, Jae-Eung;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.23 no.6
    • /
    • pp.55-60
    • /
    • 2010
  • In this paper, tensile and bending tests of glass/polypropylene composite (Twintex) specimens fabricated by various forming conditions were carried out and the results were compared according to the forming conditions to find the appropriate condition for the forming composite bone plates. From the tests it was found that the most appropriate forming conditions were $230^{\circ}C$, 3MPa. Composite bone plates were formed using this condition by two different fabricating methods for screw holes: one was a net shape molding and the other was drilling. The forming and bending tests revealed that the drilling process provided much better bending stiffness of bone plates. This paper provided the most appropriate condition for forming composite bone plates and this result was also expected to offer informative data on forming of other Twintex structures.

Anterior Cervical interbody Fusion with Cervical Spine Locking Plate (경추 물림 금속판을 이용한 경추 전방추체간 유합술)

  • Park, Joo-Tae;Ahn, Gil-Young;Lee, Young-Tae;Ahn, Myun-Whan
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.209-219
    • /
    • 1997
  • Objectives: Anterior approach to achieve arthrodesis of the cervical spine has become a widely accepted and often-used approach since its earliest reports by Bailey and Badgley, Smith and Robinson and Cloward. However, anterior interbody fusion in the presence of the posterior instability may be complicated by the bone graft dislodgement, kyphotic defomity or nonunion. As an attemp to prevent this undesirable complication, additional methods such as skeletal traction, halo appratus or even posterior fusion has been utilized. Therefore, The cervical spine locking plate(CSLP) with the anterior intervertebral body bone grafting provide immediate cervical stabilization and widely successful in achieving fusion. Material and methods: This study analysed 14 patients who underwent a single anterior procedure and application of CSLP for the treatment of the cervical spinal disorder. Eleven patients were disc herniations and three patients were traumatic lesion. The average age of the patient was 47 years and the mean follow up periods was 20 months ranging from 13 to 27 months. Results: Ambulation was started 2nd day after the operation with the aid of the Philadelpia orthoses. Bone union was observed 13 cases on average 12 weeks after operation. The one case was nonunion with plate breakage without clinical symptom. Conclusion: Anterior fusion with CSLP are thought to be a safe and valuable method for treating cervical spine disorder.

  • PDF

Analysis and Design of a New 6-DOF Haptic Device Using a Parallel Mechanism (병렬구조를 이용한 새로운 6 자유도 역감제시장치의 설계 및 해석)

  • Yoon, Jung-son;Ryu, Je-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.1
    • /
    • pp.1178-1186
    • /
    • 2001
  • This paper presents design and analysis of a 6 degree-of-freedom new haptic device using a par-allel mechanism for interfacing with virtual reality. The mechanism is composed of three pantograph mecha-misms that, driven by ground-fixed servomotors. stand perpendicularly to the base plate. Three spherical joints connect the top of the pantograph with connecting bars, and three revolute joint connect connecting bars with a mobile joystick handle. Forward and inverse kinematic analyses have been performed and the Jacobian matrix is derived by using the screw theroy. Performance indices such as GPI(Global Payload Index), GCI(Global Conditioning index), Traslation and Orientation workspaces, and Sensitivity are evaluated to find optimal pa-rameters in the design stage. The proposed haptic mechanism has better load capability than those of the ex-isting haptic mechanisms due to the fact that motors are fixed at the base. It has also wider orientation work-space mainly due to RRR type spherical joints.

  • PDF

THE CLINICAL STUDY OF FACIAL BONE FRACTURE

  • Lee, Dong-Keun;Yim, Chang-Joon;Yang, Hee-Chang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.12-20
    • /
    • 1989
  • This is a retrospective study on 452 patients with maxillofacial bone fracture. The patients were treated at the Dept. of Oral and Maxillofacial Surgery, WON KWANG UNIV. HOSPITAL from Aug. 1, 1984 to Sept. 30, 1988. The results were as follows. 1. The facial bone fractures occured most frequently in the twenties (35.3%)and male were predominant(75%) than female. 2. The most frequent etiologic factor was traffic accident. 3. The most common location of facial bone fracture was mandible(57%). Zygomatic bone & arch(39.9%) were most common on middle 1/3 of the face and symphysis(37.1%) were most common on the mandible. 4. The time from injury to treatment was variable from under the 1 week (65%) to over the 1 week(35%). In most case of the patients were treated beyond the 3 days(51.5%). 5. The relationship of intermaxillary fixation period and treatment method was an intimate relationship. The IMF period was reduced by the use of plate and screw osteosynthesis. 6. The weight loss was proportioned to intermaxillary fixation period.

  • PDF

The Management of Bilateral Interfacetal Dislocation with Anterior Fixation in Cervical Spine : Comparison with Combined Antero-Posterior Fixation

  • Kim, Ki-Hong;Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • Objective : Combined antero-posterior fixation has been a standard method for bilateral interfacetal dislocation in cervical spine. The purpose of this study is to evaluate the efficacy and complication of anterior cervical stabilization in treatment of bilateral interfacetal dislocation. Methods : A total of 65 cases of traumatic bilateral interfacetal dislocation in cervical spine who were managed in our institution, from Mar. 1997 to Feb. 2006, were included in this study. Closed reduction was tried in all cases before operation. If closed reduction was accomplished successfully, only anterior cervical fixation was performed (Group I), and attempted to place screws bicortically as possible with unicortical screws. If failed, posterior open reduction with fixation was first tried, followed by anterior cervical fixation (Group II). All patients were evaluated for neurological outcome and radiological evidence of healing. Results : The Group I included 47 patients and the Group II, 18 patients. The improvement of Frankel grade and increase of mean cervical lordosis angles were not statistically different between two groups. Screw-plate system used did not influence the outcome. On follow up, solid bone fusion was evident and there were no cases of instability in both groups. Conclusion : Our study demonstrated that anterior cervical fixation on BID is safe and effective in comparison with combined antero-posterior cervical fixation.

A Study on the Structural Design of Linear Motor System (리니어모터 시스템 구조설계에 관한 연구)

  • Eun I.E.;Lee C.M.;Hwang Y.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1059-1063
    • /
    • 2005
  • Development of a feed drive-system with high speed, positioning accuracy and thrust has been an important issue in modern automation systems and machine tools. Linear motors can be used as an efficient system to achieve such technical demands. By eliminating mechanical transmission mechanisms such as ball screw or rack-pinion, much higher speeds and greater acceleration can be achieved without backlash or excessive friction. However, due to great power loss and magnetic attraction of the linear motors heating and deflection problems occur. Therefore, it is necessary to design strong structure, cooling device with high efficiency and light weight construction in designing stage of linear motors. This paper presents an investigation into a structural design of linear motor system. In this research, a new concept of moving table with high stiffness and of cooling plate is also introduced. Structure analyses are performed by using a commercial code ANSYS in order to evaluate the design safety.

  • PDF

Guided Bone Regeneration in Comminuted Long-Bone Fractures Using Recombinant Human Bone Morphogenetic Protein-2 and a Collagen Membrane

  • Jang, Kwangsik;Jo, Hyun Min;Shim, Kyung Mi;Kim, Se Eun;Kang, Seong Soo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.59-64
    • /
    • 2022
  • A dog aged two years and seven months and a cat aged seven years were referred owing to fractures of long bones. Preoperative radiographs revealed comminuted bone fractures close to joints. Conventionally, long-bone fractures are treated using intramedullary pins, plate and screw systems, or an external fixator system. In cases of non-reducible fractures, various graft materials have been used in fracture treatments to stimulate bone repair. Here, recombinant human bone morphogenetic protein-2 (rhBMP-2) and a collagen membrane were applied. Four weeks after surgery, fractured bone fragments began to unite and the bone union was observed using radiography four months after surgery. No complications occurred related to grafted materials. We successfully applied rhBMP-2 and collagen membranes in two different species to support the healing process of comminuted fractures, according to the concept of guided bone regeneration.