• 제목/요약/키워드: Plate Chamber

검색결과 265건 처리시간 0.024초

맥동압을 가지는 챔버내의 압력변화에 관한 연구 (Study on the Pressure Variation in a Chamber Caused by Pulsation Pressure)

  • 이중섭;심규진;;정한식;정효민
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.132-138
    • /
    • 2007
  • Experimental results of pulsating pressure behavior inside a chamber have been confirmed by computational work. Inside-cylinder pressure shows unstable condition at low rpm. This is caused by plate-type suction valve. It has effect up to inlet of the chamber. But trembling phenomenon is reduced as the pressure is enlarged by increasing the rpm. Result comparison between experimental and numerical analysis shows pulsation reduction is affected by the chamber. We can confirm that compressible effect of the working flow is shown at chamber inlet by increasing rpm. On the other side, this effect is declined at chamber outlet by increasing rpm. It means outlet pressure is going on balance with atmosphere pressure. Buffer plate-type chamber has efficiency of pulsation flow reduction.

평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구 (A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume)

  • 윤형근;신교철
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.69-73
    • /
    • 2002
  • 본 연구는 제작된 평행평판형 검출기에서 두 전극간의 거리에 따른 극성효과의 정도를 확인하기 위하여 실행되었다. 개발된 전리함의 극성효과를 측정하기 위하여 평행평판형 전리함의 윗면과 아래 면의 전극에 극성을 바꾸어가며 방사선을 조사하고 그에 의하여 생성된 전하를 측정하여 두 양을 비교하였다. 실험은 두 전극간의 거리가 3, 6, 10 mm 일 때 각각의 명목상 체적이 0.9, 1.9, 3.1 cc인 평행평판형 전리함에 대하여 실행하였다. 조사된 방사선은 6, 10 MV 광자선과 4, 6, 9, 12, 16 MeV의 전자선이며, SSD는 100 cm 이었고, 조사면 크기는 광자선의 경우는 10$\times$10 ㎤ 이고 전자선의 경우는 10$\times$10 $\textrm{cm}^2$을 사용하였으며, 측정점은 최대선량점이고, 선량률은 240 MU/min 으로 하였다. 평행평판형 전리함의 극성의 변환은 평행평판형 전리함의 윗면 즉, 방사선이 입사되는 면의 전극이 (+)극을 갖고 아래 면이 (-)극을 갖는 positive와 방사선이 입사되는 면의 전극이 (-)극을 갖고 아래 면이 (+)극을 갖게 되는 negative 측정으로 시행하였다. 실험결과는 광자선의 경우는 0.5 % 이내의 극성효과를 나타냈고, 전자선의 경우는 1% 에서 3.5% 까지 나타났으며, 높은 에너지를 갖는 16 MeV 전자선의 경우가 다른 에너지의 전자선의 경우 보다 극성효과의 영향이 적음을 알 수 있다.

  • PDF

The Pumping Characteristics of the Valveless Peristaltic Micropump by the Variation of Design Parameters

  • Chang, In-Bae;Park, Dae-Seob;Kim, Byeng-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.101-109
    • /
    • 2002
  • This paper presents the fabrication and performance inspection of a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of base plate, mid plate, top plate and connection tubes fur inlet and outlet. In detail, the base plate is composed of two diffuser nozzles and three chambers, the mid plate consists of a glass diaphragm for the volumetric change of the pumping chamber. The inlet and outlet tubes are connected at the top plate and the actuator fur pressing the diaphragm is located beneath the top plate. The micropump is fabricated on the silicon wafer by DRIE (Deep Reactive ion Etching) process. The pumping performances are tested by the pneumatic test rig and compared with the simulated results fur various dimensions of diffuser nozzles. The pumping characteristics of the micropump by the volumetric change at the pumping chamber is modeled and simulated by the commercial software of FLOW-3D. The simulated results shows that reverse flow is the inherent phenomena in the diffuser nozzle type micropump, but it can be reduced at the dual pumping chamber model.

마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구 (A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.59-62
    • /
    • 2004
  • 본 논문에서는 마이크로필름과 탄소막 전극을 이용하여 개발한 소형 방사선측정기의 특성을 평가하였다. 전극은 5 mm 직경의 고전압전극, 3.3 mm 직경의 수집전극, 그리고 넓이가 0.7 mm인 보호전극으로 구성되었으며, 이온수집 공동의 부피는 0.016 ㎤이었다. 6 MV X-선을 이용하여 제작된 측정기에 대한 전기적 특성을 조사하였는데, 누설전류는 0.1 pA, 재현 오차가 0.1% 이하, 선량률 효과는 1.5% 이하, 분극효과는 2.4% 이하로 나타났다. 개발된 측정기의 전기적 특성은 양호한 것으로 평가되며, 추후 깊이선량률, 빔측면도와 같은 선량분포에 대한 특성의 평가가 요구된다.

  • PDF

25kW급 평판형 메탄-수증기 개질기 열유동 전산해석 (Computational Fluid Dynamics Analysis of 25kW Plate Type Methane-steam Reformer)

  • 신동훈;서혜경;임희천;이상득
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.103-106
    • /
    • 2006
  • The Plate reformer consisting of combustion chamber and reforming chamber for 25 kW MCFC stack has been operated and computational fluid dynamics was applied to estimate reactions and thermal fluid behavior in the reformer. The methane air 2-stage reaction was assumed in the combustion chamber, and three step steam reforming reactions were included in the calculation. Flow uniformity, reaction rate and species distribution, and temperature distribution were analyzed. In particular, temperature distribution was compared with the measurements to show good agreement in the combustion chamber, however, inappropriate agreement in the reformer chamber

  • PDF

마이크로펌프를 이용한 PCR Chip의 구동 (Operation of PCR chip by micropump)

  • 최종필;반준호;장인배;김헌영;김병희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.463-467
    • /
    • 2004
  • This paper presents the fabrication possibility of the micro actuator which uses a micro-thermal bubble, generated b micro-heater under pulse heating. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, he middle plate, the upper plate. The lower plate includes the channel and chamber are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The middle plate includes the chamber and diaphragm d the upper plate is the micro-heater. The Micropump is fabricated by bonding process of the three layer. This paper resented the possibility of the PCR chip operation by the fabricated micropump.

  • PDF

미소 챔버 내 복사열전달을 수반한 열유동 해석 (Thermal analysis inside a small chamber including radiation)

  • 이형식;도기정;이상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.194-198
    • /
    • 2006
  • In this study, numerical modeling was performed to analyze air flow including radiation heat transfer inside a small chamber. Characteristics of heat transfer between source plate and target through glass are investigated for various surface temperature of heat source plate with buoyancy effect due to gravity force. Conduction heat transfer through the glass is considered and heat source plate is assumed to be a black body. Target surface temperature is largely affected by the radiation heat transfer. It can also be seen that as the source temperature increases target surface is dominated by radiation rather than convective heat transfer by air.

  • PDF

Image Noise Reduction Using Structural Mode Shaping for Scanning Electron Microscopy

  • Hamochi, Mitsuru;Wakui, Shinji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.28-33
    • /
    • 2008
  • In a scanning electron microscope (SEM), outside acoustic noise causes image noise that distorts observations of the specimen being examined. A SEM that is less sensitive to acoustic noise is highly desirable. This paper investigates the image noise problem by addressing the mode shapes of the base plate and the transmission path of the acoustic noise and vibration. By arranging the position of the rib, a new SEM base plate was developed that had twisting as the 1st and 2nd modes. In those two twisting modes, vibration nodes existed near the center of the base plate where the specimen chamber is placed. Less vibration was transmitted to the chamber and to the specimen by the twisting modes compared to bending ones, which are the 2nd and 3rd modes for a rectangular plain base plate. An SEM with the developed base plate installed exhibited a significant reduction of image noise when exposed to acoustic noises below 250 Hz.

고온벽면에 충돌하는 디젤부문의 특성 연구 (Characteristics of a Diesel Spray Impinging on the Hot Plate)

  • 문석범;구자예
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.55-65
    • /
    • 1999
  • An experimenta investigation of unsteady impinging DI diesel spray on the unheated plate and heated plate has been conducted in a pressurized chamber using high speed shadowgraphy. The ambient agas pressure was varied using nitrogen with chamber pressure of 1.1MPa, 2.1MPa and 2.6MPa. As the increase of ambient gas pressure of ambient gas pressure, the height of spray is increased if entrainment and circulation . At higher temperature of impinging plate, the radial penetration of the impinging spary is incresed , but the height of impinging spray is decreased.

  • PDF

배선용차단기의 소호구조에 의한 한류 특성 연구 (Investigation of Arc Breaking Characteristic for Arc Chamber in Molded Case Circuit Breakerg)

  • 김용기;송중천;유만종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.708-710
    • /
    • 2001
  • In this paper, back commutation phenomena for iron chute chamber in AC low testing. For this experimental we used high speed camera and carried out with same prospective currents up to 10kA RMS. Hybrid arc quenching chambers which are composed with iron plate and insulating materials tested for reducing back commutation phenomena in interrupting process. It is shows that hybrid chambers which are various narrow slot path width reduces back commutation. As a result, a new type arc quenching chamber is to force the arc rapidly into a narrow insulating slot with iron plate. By this means the arc is lengthened and squeezed between insulating walls. Using this model, the behavior of the arc squeezed in the hybrid chamber and characteristics of arc voltage are also investigated.

  • PDF