• 제목/요약/키워드: Plate Bearing Test

검색결과 201건 처리시간 0.027초

고탄소 크롬 베어링 강에서의 잔류 오스테나이트 변화에 따른 회전접촉 피로거동 (A Behavior of Rolling Contact Fatigue on Retained Austenite in High-Carbon Chromium Bearing Steel)

  • 진재관;김동건
    • 열처리공학회지
    • /
    • 제7권3호
    • /
    • pp.190-198
    • /
    • 1994
  • In order to study the effect of retained austenite on rolling contact fatigue in high-carbon chromium bearing steel, retained austenite was controlled by only tempering temperature, individually 200, 220 and $240^{\circ}C$. Among various microstructural alteration during rolling contact fatigue test, plate-like carbide most related to the flaking at sub-surface of contact pressure. The plate-like carbides formed during rolling contact fatigue test decrease with increasing tempering temperature, and fatigue life is much more improved. The retained austenite was decreased with the tempering temperature, and that decreased plate-like carbide formation. Therefore fatigue life is much more improved with decreasing retained austenite.

  • PDF

가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험 (Model Test of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김성규;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

Analytical investigation of thin steel plate shear walls with screwed infill plate

  • Vatansever, Cuneyt;Berman, Jeffrey W.
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1145-1165
    • /
    • 2015
  • A behavior model for screw connections is developed to provide a better representation of the nonlinear response of thin steel plate shear walls (TSPSWs) with infill plates attached to the boundary frame members via self-drilling screws. This analytical representation is based on the load-bearing deformation relationship between the infill plate and the screw threads. The model can be easily implemented in strip models of TSPSWs where the tension field action of the infill plates is represented by a series of parallel discrete tension-only strips. Previously reported experimental results from tests of two different TSPSWs are used to provide experimental validation of the modeling approach. The beam-to-column connection behavior was also included in the analyses using a four parameter rotational spring model that was calibrated to a test of an identical frame as used for the TSPSW specimens but without the infill plates. The complete TSPSW models consisting of strips representing the infill plates, zero length elements representing the load-bearing deformation response of the screw connection at each end of the strips and the four parameter spring model at each beam-to-column connection are shown to have good agreement with the experimental results. The resulting models should enable design and analysis of TSPSWs for both new construction and retrofit of existing buildings.

헬리컬 파일의 지지력 산정을 위한 양방향 재하시험의 적용성 평가 (Applicability of Bi-directional Load Test for Evaluating Bearing Capacity of Helical Piles)

  • 이동섭;나경욱;이원제;김형남;최항석
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.77-85
    • /
    • 2014
  • 헬리컬 파일(helical pile)은 회전 관입기로 시공이 가능하므로 비교적 소형의 장비로 말뚝 시공이 가능한 장점이 있어, 최근 다양한 현장에서 그 사용이 증가하고 있다. 그러나 헬리컬 파일의 지지력을 평가하기 위한 현장 정재하시험은 시험하중만큼의 사하중, 반력 말뚝, 반력 앵커 등이 필요하다는 단점이 있다. 본 연구에서는 헬리컬 파일에 상대적으로 재하장치가 간단하고 시험이 간편한 양방향 재하시험을 적용하였으며, 양방향 재하시험 결과와 정재하시험 결과를 비교하였다. 양방향 재하시험은 헬리컬 파일의 중공형 중심축(shaft)에 중심축의 직경과 일치하고 중심축 내부 공간으로 유압재하용 호스가 나올 수 있도록 특수하게 제작된 유압식 셀(cell)을 나선형 원판(helix plate)사이에 삽입한 후, 유압 셀(cell)에 가압하여 지지력을 측정하는 방식으로 수행되었다. 양방향 재하시험은 유압식 셀을 최하단 나선형 원판 상부에 삽입한 경우와 최상단 나선형 원판 상부에 삽입한 두 가지 케이스로 시험을 진행하였으며, 각각의 방법이 선단지지력과 주면마찰력을 측정할 수 있도록 말뚝 두부의 변형을 제한하였다. 시험은 89mm, 114mm의 중심축에 450mm, 350mm, 200mm의 나선형 원판을 부착하여 제작한 헬리컬 파일로 수행되었으며, 시험 결과 정재하시험으로 산정한 지지력과 양방향 재하시험으로 산정한 지지력이 유사함을 확인하였다.

연약지반상 고속철도 노반 축조시 지오셀 시스템의 효과 (Reinforcement of Soft Soil Subgrade for High-Speed Railroad Using Geocell)

  • 김진만;조삼덕;윤수호;정문경;김영윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.129-141
    • /
    • 1999
  • This paper presents the results of plate load test and dynamic load test performed to evaluate the performance of geocell where it is used to reinforce soft subgrade for high-speed railroad. Efficacy of geocell was observed in increase in bearing capacity of subgrade and reduction of thickness of reinforced sub-ballast. Plate load tests were carried out at four different places with varying foundation soil strength as a function of number of geocell layer, type of filler material, thickness of cover soil, and the presence of non-woven geotextile. Dynamic load tests were performed in a laboratory. The test soil chamber consists of, from the bottom, 50 cm thick clayey soil, one layer of geocell filled with crushed stone, 10 cm thick crushed stone cover, reinforced sub-ballast of varying thickness, 35 cm thick ballast. This configuration was determined based on the results of numerical analysis and plate load tests. For each set of the dynamic load tests, loads were applied more than 80,000 times. One layer of geocell underlying a 10 cm thick cover soil led to an increase in bearing capacity three to four times compared to a crushed stone layer of the same thickness substituted for the geocell and cover soil layer. Given the test conditions, the thickness of reinforced sub-ballast can be reduced by approximately 35 cm with the presence of geocell.

  • PDF

지반반력계수$(K_{30})$와 변형률계수$(E_v)$에 대한 고찰 (Study on the subgrade reaction modulus$(K_{30})$ and strain modulus$(E_v)$)

  • 김대상;최찬용;김성중;유진영;양신추
    • 한국철도학회논문집
    • /
    • 제10권3호
    • /
    • pp.264-270
    • /
    • 2007
  • Two modulus, strain modulus $(E_v)$ and subgrade reaction modulus $(K_{30})$ are being used as a standard for bearing stiffness in Korea Railroad design. The first is used in Europe and the other is used in Japan. The methodologies to obtain the two modulus are similar in using plate. But testing methods are different in loading to plate. Therefore, according to soil strain range, there should be large gap in not only computations of deformation modulus but also the necessary time to test. At first, this paper focuses on the two kinds of test methods to evaluate bearing stiffness. Secondly, based on elastic theory, the theory to obtain the two coefficients are studied thoroughly. Finally, the correlations between the two coefficients were analyzed and evaluated based on the field test results more than 38 places. The matching values for subgrade and ground between $K_{30}$ and $E_{v2}$ are proposed with the consideration of the proposed strain reduction factor (1.5 for subgrade and 3 for ground) and safety factor, respectively.

토목섬유로 보강된 폐기물 매립지반의 지지력 특성 (Bearing Capacity of Waste Landfill Reinforced by Geosynthetics)

  • 신은철;박정준
    • 한국지반신소재학회논문집
    • /
    • 제6권3호
    • /
    • pp.39-46
    • /
    • 2007
  • 세계적으로 폐기물의 발생량이 급증하여 매립지의 숫자가 급증하고 있으나 사용이 완료된 매립지의 처리에 많은 어려움이 있다. 특히, 도시 폐기물 매립지는 인구밀집 지역과의 근접성, 부지개발에 따른 경제적 가치의 급등 등의 이유로 활용 가능한 새로운 건설부지로서 많은 관심이 집중되고 있다. 그러나, 폐기물 매립지반 위에 구조물을 축조할 경우, 특별한 안정처리 및 보강처리를 하지 않은 경우, 지반침하, 구조물에 대한 지지력 확보 등에 문제점이 발생될 수 있다. 따라서, 본 연구에서는 폐기물 매립지반위에 구조물을 축조할 경우, 지오그리드 및 지오셀의 보강 효과를 규명하고자 반복평판재하시험을 수행하여 주요 영향인자인 지지력증가비, 지반계수, 스프링상수, 탄성회복율 등을 평가하였다.

  • PDF

순환자원 활용 지반안정재의 건축물 얕은기초 보강 적용사례 연구 (Study on application case of reinforce building shallow foundation for soil stabilized materials using circulating resources)

  • 송상훤
    • 문화기술의 융합
    • /
    • 제8권3호
    • /
    • pp.457-462
    • /
    • 2022
  • 본 연구는 순환자원을 대량 활용한 지반안정재를 활용하여, 비교적 작은 하중이 작용하는 중·저층 건축물의 얕은 기초 보강공법에 적용한 사례에 대한 내용으로 우선하여 현장 최적배합비를 도출하고자 4가지 혼합비에 대한 실내배합시험을 실시하였으며, 도출된 최적배합비를 이용하여 현장에서 건축물 얕은기초로 적용하였다. 현장 적용방법은 원지반와 지반안정재를 교반한 혼합토를 현장에서 혼합하여 다짐을 실시하는 매우 단순한 공정을 이용하였다. 현장 적용 후 평판재하시험을 원지반 1곳, 개량지반 2곳에 실시하여 허용지지력을 확인하였다. 지지력 확인 결과 충분한 지지력을 발휘하는 것으로 나타나, 해당 건축물의 앝은기초로 활용이 가능한 것으로 확인되었다.

대나무 망으로 보강된 준설매립지반의 지지력 특성 (Bearing Capacity Characteristic of Dredged and Reclaimed Ground Reinforced by Bamboo Net)

  • 강명찬;양기석;이송
    • 한국지반공학회논문집
    • /
    • 제22권8호
    • /
    • pp.5-11
    • /
    • 2006
  • 준설매립된 초연약지반의 표층처리공법 적용시 보강재로 이용되고 있는 대나무망 및 토목섬유로 보강된 준설매립지반의 지지력 특성을 파악하기 위하여 현장 대형평판재하시험을 실시하였다. 각 보강재별 지지력비(BCR) 산정결과 대나무망 보강의 경우 지지력비는 $.{\sim}6.03$, 토목섬유의 경우 $2.19{\sim}3.59$로서 대나무망 보강의 경우 $1.6{\sim}1.7$배 크게 측정되었고, 실험결과와 이론식에 의한 지지력 비교결과 기존 토목섬유 보강시의 지지력 평가식은 대나무망 보강시 지지력 평가에 있어 적용성이 떨어짐을 알 수 있었다. 대나무 망 보강시의 지지력 평가를 위한 변수들의 상관관계 분석결과, 시험에서 얻어진 지지력비(BCR)와 복토두께/대나무망 간격의 비(H/S)로 표현한 경우 좋은 상관관계 특성을 얻을 수 있었고, 이는 대나무망의 지지력특성 파악을 위한 기초 자료로서 활용할 수 있을 것으로 판단되었다.

Behaviour of geocell reinforced soft clay bed subjected to incremental cyclic loading

  • Hegde, A.;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • 제10권4호
    • /
    • pp.405-422
    • /
    • 2016
  • The paper deals with the results of the laboratory cyclic plate load tests performed on the reinforced soft clay beds. The performances of the clay bed reinforced with geocells and geocells with additional basal geogrid cases are compared with the performance of the unreinforced clay beds. From the cyclic plate load test results, the coefficient of elastic uniform compression ($C_u$) was calculated for the different cases. The $C_u$ value was found to increase in the presence of geocell reinforcement. The maximum increase in the $C_u$ value was observed in the case of the clay bed reinforced with the combination of geocell and geogrid. In addition, 3 times increase in the strain modulus, 10 times increase in the bearing capacity, 8 times increase in the stiffness and 90% reduction in the settlement was observed in the presence of the geocell and geogrid. Based on the laboratory test results, a hypothetical case of a prototype foundation subjected to cyclic load was analyzed. The results revealed that the natural frequency of the foundation-soil system increases by 4 times and the amplitude of the vibration reduces by 92% in the presence of the geocells and the geogrids.