DOI QR코드

DOI QR Code

Applicability of Bi-directional Load Test for Evaluating Bearing Capacity of Helical Piles

헬리컬 파일의 지지력 산정을 위한 양방향 재하시험의 적용성 평가

  • Lee, Dongseop (School of Civil, Environmental and Architectural Engineering, Korea Univ.) ;
  • Na, Kyunguk (School of Civil, Environmental and Architectural Engineering, Korea Univ.) ;
  • Lee, Wonje (Unicorn Technical Institute Co, Ltd.) ;
  • Kim, Hyung-Nam (Sambo Geotechnical Engineering Co, Ltd.) ;
  • Choi, Hangseok (School of Civil, Environmental and Architectural Engineering, Korea Univ.)
  • Received : 2014.10.11
  • Accepted : 2014.11.25
  • Published : 2014.12.30

Abstract

The helical pile has become popular with some constructional advantages because relatively compact equipment is needed for installing helical piles. However, field loading tests for estimating the bearing capacity of helical piles have drawbacks that the required dead load should be as much as the operation load, and reaction piles or anchors are required. In this paper, the bi-directional load test without necessity of reaction piles and loading frames was applied to the helical pile, and the load-settlement curves of the helical piles were measured. The bi-directional load test was performed in two separate stages with the aid of a special hydraulic cylinder whose diameter is equal to that of the pile shaft. In the first stage, the hydraulic cylinder is assembled immediately above the bottom helix plate, and the end bearing capacity of the helical pile is measured. In the second stage, the hydraulic cylinder is assembled above the top helix plate, and the skin friction of the helical pile is measured. The pile loading-test program was carried out for the two different helical piles with the shaft diameter of 89 mm and 114 mm, respectively. However, the configuration of helix plates is identical with three helix plates of 450-, 350-, 200- mm diameter. Results of the bi-directional load test were verified by the conventional static pile loading test. As a result, the bearing capacity estimated by the bi-directional load test is in good agreement with the result of the conventional pile loading test.

헬리컬 파일(helical pile)은 회전 관입기로 시공이 가능하므로 비교적 소형의 장비로 말뚝 시공이 가능한 장점이 있어, 최근 다양한 현장에서 그 사용이 증가하고 있다. 그러나 헬리컬 파일의 지지력을 평가하기 위한 현장 정재하시험은 시험하중만큼의 사하중, 반력 말뚝, 반력 앵커 등이 필요하다는 단점이 있다. 본 연구에서는 헬리컬 파일에 상대적으로 재하장치가 간단하고 시험이 간편한 양방향 재하시험을 적용하였으며, 양방향 재하시험 결과와 정재하시험 결과를 비교하였다. 양방향 재하시험은 헬리컬 파일의 중공형 중심축(shaft)에 중심축의 직경과 일치하고 중심축 내부 공간으로 유압재하용 호스가 나올 수 있도록 특수하게 제작된 유압식 셀(cell)을 나선형 원판(helix plate)사이에 삽입한 후, 유압 셀(cell)에 가압하여 지지력을 측정하는 방식으로 수행되었다. 양방향 재하시험은 유압식 셀을 최하단 나선형 원판 상부에 삽입한 경우와 최상단 나선형 원판 상부에 삽입한 두 가지 케이스로 시험을 진행하였으며, 각각의 방법이 선단지지력과 주면마찰력을 측정할 수 있도록 말뚝 두부의 변형을 제한하였다. 시험은 89mm, 114mm의 중심축에 450mm, 350mm, 200mm의 나선형 원판을 부착하여 제작한 헬리컬 파일로 수행되었으며, 시험 결과 정재하시험으로 산정한 지지력과 양방향 재하시험으로 산정한 지지력이 유사함을 확인하였다.

Keywords

References

  1. Ayithi, A., Bullock, P.J., Khoo, H.S., Ramana, G.V. (2013) "Technical and economic benefits of o-cell load testing for deep foundations in india", Proceedings of Indian Geotechnical Conference, December 22-24, 2013, Roorkee, pp.1-9.
  2. De Beer, E. E. and Wallays, M. (1972), "Franki piles with overexpanded bases", La Technique des Travaux, No.333, 1972, 48 pp.
  3. Lee, C-S., Lee, M-H., Kim, S-I. and Choi, Y. K. (2007), "Study on Development of the Bi-directional High Pressure Pile Load Test (BDH PLT) and Its Application", Journal of the Korean Geosynthetics Society, Vol.23, No.6, pp.23-36. (in korean)
  4. Lee, J-S, Kim, H-J, Park, H-J and Kim, D-K (2008), "Application of Osterberg Cell Test on The New Method and Construction Control of Mass Concrete", Journal of KCI, Vol.20, No.2, pp.54-60. (in korean)
  5. Jeong, C-K (2004), Research on Field Application of Static End Loading Test, Kyung Sung University, Busan. (in korean)
  6. Kishida, H., Tsubakihara, Y., and Ogura, T. (1992), "Pile Loading Tests at Osaka Amenity Park Project", preprint by Mitsubishi Co..
  7. Livneh, B., Naggar, M. H. (2008), "Axial testing and numerical modeling of square shaft helical piles under compressive and tensile loading", Canadian Geotechnical Journal, Vol.45, Issue 8, pp.1142-1155. https://doi.org/10.1139/T08-044
  8. Ogura, T., Sumi, M., Kishida, H., and Yoshifuka, T. (1996), "Application of the Pile Toe Test to Cast-in-place and Precast Piles", translated by MandanB. Karkee, Foundation Drilling Magazine, ADSC, December1996/January 1997, pp.23-28.
  9. Osterberg, J. O. (1998), "The Osterberg load test method from bored and driven piles - The first ten years", Presented at 7th International Conference & Exhibition on Piling and Deep Foundations, Deep Foundations Institute, Vienna, Austria, June 1998.
  10. Perko, H. A. (2009), Helical Piles, John Wiley & Sons, Inc, Hobojen, New Jersey, p.10.

Cited by

  1. Analysis of the Bearing Capacity of Helical Pile with Hexagonal Joints vol.11, pp.10, 2018, https://doi.org/10.3390/ma11101890
  2. 내부 콘 항타를 적용한 헬리컬 파일의 지지력 및 시공성 분석 vol.16, pp.4, 2014, https://doi.org/10.12814/jkgss.2017.16.4.001
  3. 사질토에 근입된 헬릭스 피치에 따른 헬리컬 파일의 수치해석적 거동분석 vol.17, pp.4, 2014, https://doi.org/10.12814/jkgss.2018.17.4.029
  4. 헬릭스 개수 및 직경에 따른 헬리컬 파일 거동의 수치해석적 분석 vol.39, pp.1, 2019, https://doi.org/10.12652/ksce.2019.39.1.0211
  5. 사질토에서의 헬릭스 형상 및 위치에 따른 헬리컬 파일의 수직 및 수평 거동 분석 vol.40, pp.4, 2020, https://doi.org/10.12652/ksce.2020.40.4.0393