• Title/Summary/Keyword: Plastic instruments

Search Result 62, Processing Time 0.026 seconds

New Instruments and Techniques for Obtaining Septal Cartilage in Rhinoplasties (코성형술에서 코중격연골 채취에 도움이 되는 기구와 방법)

  • Oh, Sang Ha;Kang, Nak Heon;Lee, Seung Ryul;Jeong, Ji Won;Lee, Yoon Joo
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.791-795
    • /
    • 2005
  • A symmetric approach, using external rhinoplasty, is presented to aid the plastic surgeon in obtaining improved aesthetic and functional results in patients with postoperative nasal deformities. The external approach yields a full visualization of the underlying nasal framework and intraoperative evaluation of the deformities to be corrected subsequently. The nasal septal cartilage is unequivocally one of the best graft sources for reconstruction of the dorsum, columella or tip. It has fairly even surface and pliability in carving and shaping the graft. The graft can be obtained during the surgery with less morbidity and prepared easily for need of the shape. The only real disadvantage is the limited amount of cartilage that can be obtained from the septum. The dorsal and caudal rims, one or more cm in width, of the nasal septum should not be disturbed to maintain the nasal frame during harvesting the septal graft. Authors invented novel instruments, J & D knife and Flat (Spatula) suction tip, and have employed the devices for harvesting the septal cartilage. We were unable to gain enough amount of the cartilage by using a swivel knife or cartilage scissors. The septal cartilage can be resected as much as needed with newly invented instruments which facilitate a separation(method) technique.

Removal of Broken Instruments in Soft Tissue at Mandibular Area Using a Dental Mini C-arm: Case Reports (치과용 소형 C자형 투시장치를 이용한 하악 연조직에 위치한 부러진 기구의 제거: 증례보고)

  • Park, Sung-Soo;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 2010
  • Intraoperative breakage of instruments can be occurred unexpectedly. To prevent damage of neighboring important anatomic structures and consequent complications, broken instruments should be removed as soon as possible. There have been several methods to remove broken instruments. One of them is the Carm fluoroscopy which is commonly used for locating metal foreign bodies. However, its application for removal of broken instruments in the oral and maxillofacial area is not common. In our experiences with the removal of two broken instruments in mandibular area, the newly developed dental mini C-arm was used to find broken instrument in soft tissue, because it gives real-time in situ information for the intraoperative location. We report two cases with broken instruments, a broken dental needle in the pterygomandibular space and a broken straight bur in the mandibular angle area. They were identified and could be removed safely using a dental mini C-arm.

Possibility of Local Recurrence Caused by Surgical Instruments in the Mouse Skin Cancer Model (백서 모델에서 수술 기구를 통한 피부악성종양의 국소 재발 가능성)

  • Kim, Gook-Jin;Lee, Hyoung-Suk;Kim, Nam-Gyun;Lee, Kyung-Suk;Kim, Jun-Sik;Park, Sang-Woo
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.339-344
    • /
    • 2011
  • Purpose: The goal of cancer surgery is complete removal of cancer tissue and prevention of recurrence. Surgeons can change the surgical instruments after total resection of the cancer mass. The purpose of this procedure is to prevent dissemination of the cancer cells attached to the surgical instruments. Authors hypothesize the possibility of local recurrence caused by the cancer cells attached to the surgical instruments in the skin cancer cases. Methods: Skin cancers were induced by using DMBA-TPA two-stage carcinogenesis model in 10 of Balb/c mice. In 2-weeks, skin cancer was developed in all 10 mice. cancer cell attached surgical instruments were made by pinching the removed cancer tissue using Adson tissue forcep 10, 20, 30 times each. To count number of cancer cells in each forcep with different number of pinching was done, the forceps were washed in 30 mL of the normal saline and Cytospin preparation was done. To make recurrence models from cancer cell attached surgical instrument, three incisions were made in normal skin of each mouse, and local seeding was done by pinching subcutaneous tissue in 10, 20, 30 times each by using Adson teeth forceps mentioned above as cancer cell attached surgical instrument. Results: All skin cancers were squamous cell carcinoma. Local recurrences were developed in 7 mice (3 in 10 times forceping site, 2 in 20 times forceping and 3 in 30 times forceping). In the cytospin test, the mean number of squamous cells in 100 microscope was 28.6 in 10 times, 47.2 in 20 times, 93.6 in 30 times, respectively. P value was 0.002 in Wilcoxon-Sign test. Conclusion: The number of cell count was significantly increased as number of pinching was increased. And these cells are able to induce local recurrence by local seeding. Considering this result, authors are able to confirm that the minimal handling in cancer surgery is important factor to prevent local recurrence.

Fifty Years of Innovation in Plastic Surgery

  • Kwasnicki, Richard M;Hughes-Hallett, Archie;Marcus, Hani J;Yang, Guang-Zhong;Darzi, Ara;Hettiaratchy, Shehan
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.145-152
    • /
    • 2016
  • Background Innovation has molded the current landscape of plastic surgery. However, documentation of this process only exists scattered throughout the literature as individual articles. The few attempts made to profile innovation in plastic surgery have been narrative, and therefore qualitative and inherently biased. Through the implementation of a novel innovation metric, this work aims to identify and characterise the most prevalent innovations in plastic surgery over the last 50 years. Methods Patents and publications related to plastic surgery (1960 to 2010) were retrieved from patent and MEDLINE databases, respectively. The most active patent codes were identified and grouped into technology areas, which were subsequently plotted graphically against publication data. Expert-derived technologies outside of the top performing patents areas were additionally explored. Results Between 1960 and 2010, 4,651 patents and 43,118 publications related to plastic surgery were identified. The most active patent codes were grouped under reconstructive prostheses, implants, instruments, non-invasive techniques, and tissue engineering. Of these areas and other expert-derived technologies, those currently undergoing growth include surgical instruments, implants, non-invasive practices, transplantation and breast surgery. Innovations related to microvascular surgery, liposuction, tissue engineering, lasers and prostheses have all plateaued. Conclusions The application of a novel metric for evaluating innovation quantitatively outlines the natural history of technologies fundamental to the evolution of plastic surgery. Analysis of current innovation trends provides some insight into which technology domains are the most active.

Inexpensive Materials for Microsurgery in Middle- and Low-Income Countries

  • Pedro Ciudad;Joseph M. Escandon;Edgar Llanos;Juan Ludena;Oscar J. Manrique;Jorge Castro;Rafael Rossi
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.121-124
    • /
    • 2023
  • With the continuous incorporation of new technologies and advancements in surgical technique, microsurgical procedures around the world have generated a higher success rate and innovative procedures are now possible. In this setting, limitations regarding accessibility and acquisition of medical resources and equipment for these types of operations may be difficult in developing countries. We believe the dexterities of surgeons go beyond the surgical technique, meaning that we are able to use everyday materials to re-create affordable solutions that can be used during surgery in a safe way. This manuscript presents our experience with different surgical instruments and gadgets, developed out of necessity, to improve microsurgical interventions in developing countries.

Study on Improvement of Working Environment in Plastic House to Prevent Plastic House Syndrome (하우스증 예방을 위한 비닐하우스내 작업환경 개선에 관한 연구)

  • 김명주;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.5 no.2
    • /
    • pp.107-115
    • /
    • 1994
  • This study was conducted to provide a counterplan for preventing so celled “plastic house syndrome” revealed among farmers spending much time in the plastic houses. For this, working environment inside a plastic house was observed. Then, experiments were carried out mostly in a climatic chamber with three kinds of working posture on uneven($D_1-F_1$) or even($D_2-F_2$) ground surface. Tested work loads with three kinds of working posture were : moving in a sitting posture with attaching breast to legs and waving arms ($A_1$), moving in a bending posture with waving arms ($B_1$), and moving a 6kg weighting luggage in a standing posture ($C_1$) Physiological responses in the workers to three different work loads were observed in a climatic chamber, with or without using some instruments, to evaluate work efficiencies. The results obtained are summerized as follows. 1. $C_1$ was the hardest work and $B_1$ was harder than $A_1$ on the even ground. 2. Worker's physiological fatigue and physical loads remarkably decreased when using the instruments such as a chair and a cart with some rollers on the even ground. 3. Working with pushing a cart($F_1$) was the hardest work, and standing($D_1$) was harder than walking($E_1$) on the uneven ground. 4. Worker's physiological fatigues and physical loads remarkably decreased on the even ground. 5. Similar results were obtained when the same experiment was carried out in a plastic house.

  • PDF

A hands-on microsurgery course for nurses

  • Satkunanantham, Mala;Sechachalam, Sreedharan
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.305-309
    • /
    • 2021
  • Microsurgical procedures are time-consuming and sometimes fatigue-inducing. However, a skilled assistant and scrub nurse can help surgery be performed more smoothly and rapidly. Three microsurgical simulation courses were held for perioperative nurses at our institution. Each course consisted of two lectures and two practice microsurgical sessions, and was evaluated with a post-course survey. The respondents all felt that their knowledge of microsurgical instruments, sutures, microscope set-up, and microsurgical skills had improved following the course. Many felt that their ability to predict what the surgeon would request during a microsurgical case improved, and that they were able to handle instruments and sutures better. The nurses also reported improved confidence in assisting with microsurgical procedures and tolerance of the long operative time in some microsurgical cases. Based on our experience, a basic microsurgery course for nurses can play a significant role in training effective and competent microsurgical scrub nurses.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Attachment of Human Gingival Fibroblasts to Commercially Pure Titanium Surfaces with Different Instruments;A comparative Study in Vitro (기구조작에 따른 순수 타이타늄 표면 변화와 치은 섬유아 세포 부착에 관한 연구)

  • Seo, Sung-Chan;Song, In-Taeck;Lim, Jeong-Su;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.607-621
    • /
    • 1999
  • This study examined the human fibroblasts cell attachment to commercially pure titanium surface which had been instrumented by 3 types of periodontal instruments. Commercially pure titanium plates were uniformly scaled using plastic, stainless steel, titanium curette. these all experimental groups 65 undirectional strokes with the designated curettes. Alteration of the surfaces due to instrumentation was evaluated by Form Talysurf(R) and reported as Ra value(mean surface roughness). Then other experimental groups were immersed in a cell suspension of human gingival fibroblasts($1{\times}10^5$ cell/ml). After 3 days of culture, cell attachment and morphology was observed by SEM, and attached cell were counted by Hemocytometer. A significant difference in mean Ra value was observed for surface instrumented by metal curette compared to either control surface or surface instrumented by the plastic curette(P<0.01). No stastically significant difference was noted between control surface and those instrumented by the plastic curette. SEM observation showed that cell morphology and attachment to the commercially pure titanium plate was similar appearance on the all experimental groups. Experimental groups instrumented by titanium curette and stainless steel curette were more attached cell number than control group, but experimental group instrumented by plastic curette were similar with control groups(P<0.01). In summary, metal curette produced an significant alteration of the commercially pure titanium surface and more favorable surface topography for cell attachment. Otherwise plastic curette was insignificantly altered the commercially pure titanium surface(P<0.01).

  • PDF

LightSpeed and SimpliFil : Designed for Successful Endodontics

  • Senia, Steve
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.259-259
    • /
    • 2001
  • ;A new root canal instrument and instrumentation technique: a preliminary report. Cleaning and shaping the root canal system has been and continues to be a challenge for even the most experienced endodontist. Curved. narrow canals. in particular. cause difficulties for the beginner as well as the specialist. A new instrument designed to incorporate new concepts was developed to ameliorate the problems in cleaning and shaping root canal systems. This new instrument has been given the name of SW (Senia and Wildey). The new SW instrument uses controlled right and left rotational forces. This motion was used to clean and shape simulated root canals in plastic blocks and root canals in extracted teeth. Instrumentation appeared to be easier. faster. and more precise than with conventional instruments. especially in curved canals where there was remarkable reduction of canal transportation. A mechanical version of the SW instrument was also developed. It was used to flare the coronal portion of the root canal system. Wildey WL. Senia ES., Oral Surg Oral Med Oral Pathol1989 Feb:67(2):198-207 Another look at root canal instrumentation. Several aspects of root canal instrumentation need additional research. Various factors must be considered in an analysis of instrumentation of the root canal system: the dentin that is cut: the technique used to cut it: the design of the instruments: the material and manufacturing process used to make the instruments: the irrigant used during the procedure: and the anatomic configuration of the root canal system. An analysis of these factors clearly indicates that existing root canal instruments and techniques are less than ideal and. in fact. do not accomplish what is expected of them. Root canals must be properly. but. at the same time. destructive and unnecessary removal of dentin should be kept to a minimum. The Flex-R and Canal Master instruments were developed to address some of the shortcomings of existing instruments and techniques. More scientifically based research is needed to fully evaluate these new instruments and techniques and to develop future instruments. Wildey WL; Senia ES. Montgomery S., Oral Surg Oral Med Oral Pathol1992 Oct:74(4):499-50799-507

  • PDF