• 제목/요약/키워드: Plastic injection

검색결과 709건 처리시간 0.028초

플라스틱 비구면 픽업 렌즈의 사출조건에 대한 수차변화 연구 (A Study of the Effects of Injection Conditions on Aberration Change of Aspherical Plastic Pick-up Lens)

  • 현동훈;이승준;이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.70-75
    • /
    • 2004
  • In this study, the pattern of lens aberration was studied at different injection molding conditions such as injection speed, holding pressure, holding pressure time, mold temperature and cylinder temperature and, then, the results were analyzed with a laser interferometer. It was demonstrated that optimal condition of lens aberration could be achieved by adjustment of injection molding conditions.

  • PDF

미소 원주의 사출 성형 실험 (Injection Molding Experiments for Small Diameter Column)

  • 제태진;이응숙;김재구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 1995
  • Recently, the micro mold maching techining technology is developed by means of the mechanical and high energy beam process. It is possible to make the micro structure mold with high aspect ratio by the LIGA technology. This mode is used for mass production of plastic parts by the micro injection molding method. In this study, we intend to research on the basic technology of micro injection molding. As the result, we developed the injection molding technology for small column plastic parts which diameter is 500 .mu. m and 200 .mu. m respectively with wbout aspect ratio 20.

  • PDF

사출 성형 플라스틱 단붙이 기어의 강도평가 (Strength Estimation of Injection Molded Plastic Stepped Spur Gear)

  • 정태형;문창기;하영욱
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.17-23
    • /
    • 2006
  • The strength estimation is carried out for injection molded plastic stepped gear. The stepped gear is considered as a plate model which is fixed by two edges and freed on the other sides. The stress of common normal gear is calculated by Lewis formula which can be derived quite simply from the equation fur the stress at the root of a cantilever beam. Stress ratio(step factor) between the common normal gear and stepped gear is proposed for the ratio of the bending stress of normal gear and that of stepped gear. This study proposes the step factor added in Dupont equation which is used for strength estimation of injection molded plastic stepped gear.

사출성형공정에 의한 엔지니어링 플라스틱 기어 개발 (Development of Engineering Plastic Gear Based on Injection Molding Process)

  • 민병헌
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.71-78
    • /
    • 1999
  • The application range of injection molded parts is expanding by the development of engineering plastics with good mechanical properties. Plastic gears are specially used as automotive parts due to an excellent performance in the characteristics of a strength vs. weight, and the study of injection molding process of plastic gear using Nylon66 is performed in this study. Filling, packing and cooling analyses were done by using the simulation software like Moldflow, and a mold was designed by following the simulation results. Pin-point gates with three points were taken to satisfy the design guides like a full-shot, and lower clamping force and uniform shrinkage. Characteristics of shrinkage of molded gear and temperature difference between cavity and core sides of a mold were shown.

  • PDF

QUALITY STABILIZATION OF BALL SEAT IN AUTOMOTIVE SUSPENSION PARTS

  • KANG T.-H.;KIM I.-K.;KIM Y.-S.
    • International Journal of Automotive Technology
    • /
    • 제6권5호
    • /
    • pp.507-511
    • /
    • 2005
  • Recently, many solution have been suggested to development of plastic products. Among many manufacturing technologies for plastic parts, the injection molding process is very attractive because of its low production cost and short cycle time. In this paper, the plastic ball seat of a ball joint, one of the essential components for automotive suspension or steering system, was studied to enhance its mechanical performance and durability by using PA66 that is reinforced polymeric plastic resin. But ball seat has some trouble in manufacture process. And strength of molded part is not enough to use. For the quality stabilization and reliability of injection molded parts, we designed the mold cavities through analytical simulation software and tested the mechanical performance for the injection molded ball-seat parts. After modification, tensile strength increases by about $13.5\%$. Strength and quality stabilization is improved.

복잡한 3차원 곡면을 가지는 플라스틱 사출 성형품을 위한 진원도의 수학적 모델링 (Mathematical Modeling of the Roundness for Plastic Injection Mold Parts with Complicated 3D curvatures)

  • 윤선진
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.6-11
    • /
    • 2019
  • In this study, we constructed the mathematical model to evaluate the roundness for plastic injection mold parts with complicated 3D curvatures. Mathematically we started off from the equation of circle and successfully derived an analytical solution so as to minimize the area of the residuals. On the other hand, we employed the numerical method the similar optimization process for the comparison. To verify the mathematical models, we manufactured and used a ball valve type plastic parts to apply the derived model. The plastic parts was fabricated under the process conditions of 220-ton injection mold machine with a raw material of polyester. we experimentally measured (x, y) position using 3D contact automated system and applied two mathematical methods to evaluated the accuracy of the mathematical models. We found that the analytical solution gives better accuracy of 0.4036 compared to 0.4872 of the numerical solution. The numerical method however may give adaptiveness and versatility for optional simulations such as a fixed center.

재활용을 위한 몰드베이스 구조 및 표준화 (The Structure and Standardization of Mold Base for Recycling)

  • 제덕근;한성렬;송준엽;정영득
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.225-231
    • /
    • 2003
  • The injection molding is a traditional manufacturing method that can make plastic parts by just one time in mold. Therefore, the injection molding has become one of a manufacturing method, which is widely applied in a producing of plastic products. Nowadays, to use of plastic parts has increased and plastic product-model using term has been shorten. By these reasons, using term of a injection mold has fast been reduced. These produced molds will be disused and leaved in a storage after a regular term to use it. These leaved molds are sometime sold as scrap iron. But, these molds have lots parts for recycling except special parts for example, cavities, cores and eject pins, etc. In this research, we investigated when the cavity and core of in injection mold would be changed, the injection mold could be recycled. We suggested the structures and standardizations for recycling of a moldbase. We also developed a program in which can be used when the recycling moldbase design in the Auto-CAD with the recycling standards. We called this program as the Recy-Mold. For the availability of the program and moldbase structure fur the recycling standards, we experimented a used mold for automobile lens, which was remanufactured by the recycling standard. The results of this test showed feasibility for the recycling mold.

Wound healing effects of paste type acellular dermal matrix subcutaneous injection

  • Lee, Jin Ho;Kim, Jae-Won;Lee, Jun-Ho;Chung, Kyu Jin;Kim, Tae Gon;Kim, Yong-Ha;Kim, Keuk-Jun
    • Archives of Plastic Surgery
    • /
    • 제45권6호
    • /
    • pp.504-511
    • /
    • 2018
  • Background Acellular dermal matrix (ADM) helps wound healing by stimulating angiogenesis, acting as a chemoattractant for endothelial cells, providing growth factors, and permitting a substrate for fibroblasts to attach. The current standard for using paste-type ADM (CG Paste) in wound healing is direct application over the wounds. The major concerns regarding this method are unpredictable separation from the wounds and absorption into negative-pressure wound therapy devices. This study aimed to investigate the effects of subcutaneous injection of paste-type ADM on wound healing in rats. Methods Full-thickness skin defects were created on the dorsal skin of rats. Eighteen rats were randomly divided into three groups and treated using different wound coverage methods: group A, with a saline dressing; group B, standard application of CG Paste; and group C, injection of CG Paste. On postoperative days 3, 5, 7, 10, and 14, the wound areas were analyzed morphologically. Histological and immunohistochemical tissue analyses were performed on postoperative days 3 and 7. Results Groups B and C had significantly less raw surface than group A on postoperative days 10 and 14. Collagen fiber deposition and microvessel density were significantly higher in group C than in groups A and B on postoperative days 3 and 7. Conclusions This study showed comparable effectiveness between subcutaneous injection and the conventional dressing method of paste-type ADM. Moreover, the injection of CG Paste led to improved wound healing quality through the accumulation of collagen fibers and an increase in microvessel density.

Case Reports of Adipose-derived Stem Cell Therapy for Nasal Skin Necrosis after Filler Injection

  • Sung, Ha-Min;Suh, In-Suck;Lee, Hoon-Bum;Tak, Kyoung-Seok;Moon, Kyung-Min;Jung, Min-Su
    • Archives of Plastic Surgery
    • /
    • 제39권1호
    • /
    • pp.51-54
    • /
    • 2012
  • With the gradual increase of cases using fillers, cases of patients treated by non-medical professionals or inexperienced physicians resulting in complications are also increasing. We herein report 2 patients who experienced acute complications after receiving filler injections and were successfully treated with adipose-derived stem cell (ADSCs) therapy. Case 1 was a 23-year-old female patient who received a filler (Restylane) injection in her forehead, glabella, and nose by a non-medical professional. The day after her injection, inflammation was observed with a $3{\times}3cm$ skin necrosis. Case 2 was a 30-year-old woman who received a filler injection of hyaluronic acid gel (Juvederm) on her nasal dorsum and tip at a private clinic. She developed erythema and swelling in the filler-injected area A solution containing ADSCs harvested from each patient's abdominal subcutaneous tissue was injected into the lesion at the subcutaneous and dermis levels. The wounds healed without additional treatment. With continuous follow-up, both patients experienced only fine linear scars 6 months postoperatively. By using adipose-derived stem cells, we successfully treated the acute complications of skin necrosis after the filler injection, resulting in much less scarring, and more satisfactory results were achieved not only in wound healing, but also in esthetics.

백서 복직근피판의 허혈-재관류 손상에 대한 히스타민 차단제의 효과 (The Effects of Anti-Histamine and Mast Cell Stabilizer against Ischemia-Reperfusion Injury to TRAM Flap in Rat)

  • 강상윤;정윤규;심정연
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.742-747
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the role of mast cell and histamine as typical product of mast cell in ischemia-reperfusion injury of muscle flap using H2 receptor blocker and mast cell stabilizer. Methods: Thirty-five Sprague-Dawley rats weighing 250-300 gm were divided into four groups; Group I: Control group without ischemia, Group II: Normal saline injection group with ischemia, Group III: Cimetidine injection group with ischemia, Group IV: Sodium cromoglycate injection group with ischemia. Well established single pedicled transverse rectus abdominis musculocutaneous(TRAM) flap was designed in all rats and were rendered ischemia by clamping the artery for 150 minutes. All injections were applied intramuscular around gluteal area 30 minutes before reperfusion. The flap survival was evaluated at 7 days after operation. Neutrophil counts and mast cell counts were evaluated 24 hours after reperfusion. Results: The difference of skin flap survival between control group and cimetidine injection group was not significant. In the normal saline injection group flap survival was markedly decreased compared to that of control group. The muscle flap survival was similar to the results of skin flap survival. The neutrophil counts were significantly decreased in control group and sodium cromoglycate injection group than normal saline injection group. The mast cell counts were significantly decreased in cimetidine injection group and control group than both normal saline injection and sodium cromoglycate injection groups. The protective effect of sodium cromoglycate was not seen in the skin flap, but the muscle flaps showed protective effects of sodium cromoglycate compared to normal saline injection group. Conclusions: It is suggests that commonly used antihistamine(H2 receptor blocker) has protective effect against ischemia-reperfusion injury to skin and muscle flaps by reducing neutrophil and mast cell. The mast cell stabilizer was not effective for skin flap but, possibly, for muscle flap.