• Title/Summary/Keyword: Plastic Stability

Search Result 604, Processing Time 0.031 seconds

The factors that influence postoperative stability of the dental implants in posterior edentulous maxilla

  • Kim, Yun-Ho;Choi, Na-Rae;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.2.1-2.6
    • /
    • 2017
  • Background: All clinicians are aware of the difficulty of installing a dental implant in posterior maxilla because of proximate position of maxillary sinus, insufficient bone width, and lower bone density. This study is to examine which factors will make the implantation in the posterior maxilla more difficult, and which factors will affect the postoperative implant stability in this region. Methods: Five hundred seventy-three fixtures on the maxilla posterior were included for this study from all the patients who underwent an installation of the dental implant fixture from January 2010 to December 2014 at the Department of Oral and Maxillofacial Surgery in Pusan National University Dental Hospital (Yangsan, Korea). The postoperative implant stability quotient (ISQ) value, fixture diameter and length, presence of either bone graft or sinus lift, and graft material were included in the reviewed factors. The width and height of the bone bed was assessed via preoperative cone beam CT image analysis. The postoperative ISQ value was taken just before loading by using the OsstellTM $mentor^{(R)}$ (Integration Diagnostics AB, Gothenburg, Sweden). The t test and ANOVA methods were used in the statistical analysis of the data. Results: Mean ISQ of all the included data was 79.22. Higher initial bone height, larger fixture diameter, and longer fixture length were factors that influence the implant stability on the posterior edentulous maxilla. On the other hand, the initial bone width, bone graft and sinus elevation procedure, graft material, and approach method for sinus elevation showed no significant impact associated with the implant stability on the posterior edentulous maxilla. Conclusions: It is recommended to install the fixtures accurately in a larger diameter and longer length by performing bone graft and sinus elevation.

Extended Indications of Bilhaut-Cloquet Procedure for Type III and IV of Duplicated Thumb (무지 다지증 III, IV형의 치료에 Bilhaut-Cloquet 방법의 적극적 이용)

  • Lim, Young-Bin;Seul, Jung-Hyun;Nam, Hyun-Jae;Woo, Sang-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.821-828
    • /
    • 2011
  • Purpose: The authors applied Bilhaut-Cloquet procedure to Wassel type III and IV duplicated thumb, which was limited to patients with Wassel type I, II. This procedure was applied in order to improve the growth potential, range of joint motion, joint stability and cosmetic outcome. Methods: Sixteen patients received Bilhaut-Cloquet procedures to correct duplicated thumbs from May, 2005 to December, 2010. Seven patients were Wassel type III, nine patients were type IV. This procedure was applied not only to balanced type, but also unbalanced type or convergent type. Five patients were balanced type and eleven patients were unbalanced type. Convergent type of Wassel type IV was three. Sex ratio was the same, mean age at the operation was 20.1 months old (8~52 months old). Angular deformity, joint stability and range of joint motion and cosmetic outcome were considered together and estimated in Tada score. Also, postoperative subjective satisfaction score of the parents was evaluated by a 100-points scale. Results: Mean subjective satisfaction scored 75 points at 28 months after the operation. Radiologic study showed bony union of proximal phalangeal bone and stable joint in all patients. Range of motion was mean 20 degrees in interphalangeal joint and mean 73 degrees in metacarpophalangeal joint. Tada score showed 'good' in eleven patients (68.8%), 'fair' in three patients (18.7%) and 'poor' in two patients (12.5%). In seven patients those who were able to follow up for a long term showed no significant difference in length of proximal and distal phalangeal bones compared to the opposite thumb. Conclusion: Bilhaut-Cloquet procedure can be applied not only to balanced type of Wassel type III, IV duplicated thumb, but also to unbalanced type or convergent type that focused on functional reconstruction and cosmetic improvement.

Stability Analysis and Reinforced Design Method of Excavation Slopes (굴착사면의 안정해석과 보강설계법)

  • 강예묵;이달원;조재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.5
    • /
    • pp.140-154
    • /
    • 1996
  • In this study, displacement, deformation, and stability according to change of cohesion and internal friction angle were investigated through elasto-plastic method, finite-element method, and in-site experiment when excavating soft ground using sheet pile. The results of the study were as follows : 1. The horizontal displacement was 5.5% of the excavation depth by the elasto-plastic method and 3.9% of the excavation depth by the on-site experiment at the final excavation depth(GL-8.Om) on the condition of double stair strut after excavating GL-6.Om. 2. Relationships between cohesion(c) and internal friction angle $({\varphi})$ when safety factor to the penetration depth was 1.2 is shown in the following equations : (a) c= -O.0086$({\varphi})$+ O.3(D=3m) and (b) c=-0.00933$({\varphi})$+0.14(D=4m). 3. The results of elasto-plastic method and the experiment show that possible excavation depth was GL-6.Om after setting single stair strut in a short period in terms of possibility of carrying out on the condition of experimental site on the contrary general reinforcement method, setting double stair strut after excavating GL-4.0m. 4. After setting the strut, distribution of the horizontal displacement had concentrated on the excavation base and possible local failure which the shear strain caused decreased by the strut reinforced. 5. After setting strut, displacement of sheet pile was decreased by half, the limit of stable excavation depth of ground was GL-8.Om, and the maximum horizontal displacement at the GL-8.Om was 1.6% of excavation depth by the elasto-plastic method, 0.7% of excavation depth by the finite-element method.

  • PDF

A New Method for Elasto-Plastic Analysis of Concrete Lining Installed in a Deep Circular Tunnel (심부 원형터널에 시공된 콘크리트 라이닝의 새로운 탄소성해석법)

  • Lee, Youn-Kyou;Park, Kyung-Soon;Song, Won-Kyong;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.19 no.4
    • /
    • pp.355-365
    • /
    • 2009
  • This paper proposes an elasto-plastic finite difference method which is useful for the stability evaluation of concrete lining installed in a deep circular tunnel. Mohr-Coulomb criterion is assumed for the condition of yielding in both the rock mass and concrete lining. In order to take into account the installation delay of lining after the excavation, the outer boundary pressure acting on the lining was calculated with the consideration of the convergence occurred before the lining installation. The distributions of stress and displacement in the rock mass and lining were calculated based on the method proposed Lee & Pietruszczak (2008). The applicability of the proposed method was demonstrated by conducting the elasto-plastic analysis of concrete lining supporting an imaginary compressed air storage tunnel. The analysis result revealed that the exact determination of the boundary pressures acting on the concrete lining is of importance in the stability analysis of concrete lining.

Advanced Treatment of Sewage Using Waste Plastic Vessel Media (폐플라스틱용기 미디어를 활용한 오수고도처리)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-61
    • /
    • 2006
  • The object of this study was to develop an advanced method for fluid flow and oxygen transmission and increase adhesive property of microorganism to waste plastic vessel that was made of microorganism media. Through lab scale experiments, we found the optimum packed media volume rate and method, and when the optimum condition was applied to pilot plant, we confirmed possibility of advanced treatment. The sewage that was used in the test was the sewage disposal facility established in C and K elementary schools, which utilized waste plastic media oxidation engineering method. Analysis showed that removal efficiency of organic matter, SS, T-N and T-P was very high, that the sewage disposal facility maintained stability of treatment when changeable load of raw sewage flowed in.

Microplate Fixation without Maxillomandibular Fixation in Double Mandibular Fractures

  • Song, Seung Wook;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.53-58
    • /
    • 2014
  • Background: Maxillomandibular fixation (MMF) is usually used to treat double mandibular fractures. However, advancements in reduction and fixation techniques may allow recovery of the premorbid dental arch and occlusion without the use of MMF. We investigated whether anatomical reduction and microplate fixation without MMF could provide secure immobilization and correct occlusion in double mandibular fractures. Methods: Thirty-four patients with double mandibular fractures were treated with open reduction and internal fixation without MMF. Both fracture sites were surgically treated. For bony fixations, we used microplates with or without wire. After reduction, each fracture site was fixed at two or three points to maintain anatomical alignment of the mandible. Interdental wiring was used to reduce the fracture at the superior border and to enhance stability for 6 weeks. Mouth opening was permitted immediately. Results: No major complications were observed, including infection, plate exposure, non-union, or significant malocclusion. Five patients experienced minor complications, among whom the only one patient experienced a persistant but mild malocclusion with no need for additional management. Conclusion: This study showed that double mandibular fractures correction with two-or three-point fixation without MMF simplified the surgical procedure, increased patient comfort, and reduced complications, due to good stability and excellent adaptation.

Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience

  • Kim, Young Geun;Yoon, Sung Ho;Oh, Jae Wook;Kim, Dae Hwan;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2022
  • Background: Intermaxillary fixation (IMF) is a technique that allows for the reduction and stabilization of mandibular fractures. Several methods of IMF, such as self-tapping screws or arch bars, have been developed. This study aimed to validate the usefulness of IMF with a self-tapping screw compared to IMF with arch bars with focus on the patients' perspective. Methods: We retrospectively reviewed the medical records of all patients who were treated for mandibular fractures at our hospital between August 2014 and February 2021. A total of 57 patients were enrolled in this study. Thirteen patients were excluded from the analysis: three patients were lost to follow-up, and 10 patients did not undergo IMF. Finally, 44 patients were analyzed, of which 31 belonged to the arch bar group, and 13 belonged to the screw group. Patient discomfort and pain during IMF application and removal were analyzed using a patient self-assessment questionnaire. The surgeon also assessed oral hygiene, IMF stability, and occlusion. Results: We applied IMF to 34 men (77%) and 10 women (23%). The mean age of the patients was 37.3 years. The most common fracture site was the angle (30%), followed by the parasymphysis (25%), the body (23%), the condyle (11%), and the ramus (11%). Patient discomfort and oral hygiene were statistically favorable in the screw group. The IMF application time was statistically shorter in the screw group (p< 0.001). IMF stability was not statistically different between the two groups. The pain score during IMF removal was lower in the screw group (p< 0.001). Conclusion: Compared to arch bars, IMF screws provide more comfort during the IMF period, help maintain favorable oral hygiene, and have a shorter application time. From the patient's perspective, IMF screws are an excellent alternative to conventional arch bars when applicable.

Plastic LCDs Using Pixel Isolated LC mode

  • Jung, Jong-Wook;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1220-1222
    • /
    • 2004
  • We developed a new device structure using anisotropic phase separation from liquid crystal (LC) and polymer composite materials using UV intensity variation and polymer wetting properties. In the device, the LC molecules are isolated in pixels where LCs are surrounded by the inter-pixel vertical polymer walls and the horizontal polymer films on the upper substrate. These devices show very good mechanical stability against external pressure. The electro-optic characteristics and the mechanical stability of the devices are discussed in view of the flexible display applications.

  • PDF

Stability Analysis of a Subway Tunnel Excavated in Soft Rock (연약암반에 굴착되는 지하철 터널의 안정성 해석)

  • 이연규;서영호;이정인
    • Tunnel and Underground Space
    • /
    • v.3 no.2
    • /
    • pp.118-131
    • /
    • 1993
  • In this study, the results of elasto-plastic analysis for a subway tunnel using finite element method are presented. To determine input data for the analysis we carried out rock mass classificaton, insitu test and back analysis using measured displacements. Tunnel convergence, extension of yielding Zone and support load are described. By comparing the results of four different reinforcement patterns, the influence of those patterns on tunnel stability is presented. As a result of the analysis we suggest a ratonal reinforcement pattern.

  • PDF

Energy dissipation response of brick masonry under cyclic compressive loading

  • Senthivel, R.;Sinha, S.N.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.4
    • /
    • pp.405-422
    • /
    • 2003
  • Scaled brick masonry panels were tested under cyclic unialxial compression loading to evaluate its deformation characteristics. An envelope stress - strain curves, a common point curves and stability point curves were obtained for various cyclic test conditions. Loops of the stress-strain hysteresis were used to determine the energy dissipation for each cycle. Empirical expressions were proposed for the relations between energy dissipation and envelope and residual strains. These relations indicated that the decay of masonry strength starts at about two-third of peak stress.